메뉴 건너뛰기




Volumn 27, Issue 4, 2000, Pages 662-667

A high-precision, high-resolution and fast dosimetry system for beta sources applied in cardiovascular brachytherapy

Author keywords

Absorbed dose calibration; Intravascular brachytherapy; Plastic scintillator dosimeter; Vascular restenosis; dosimetry

Indexed keywords

ONCOLOGY; RADIOTHERAPY; SCINTILLATION COUNTERS;

EID: 0343776958     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598927     Document Type: Article
Times cited : (40)

References (28)
  • 1
    • 0021795598 scopus 로고
    • Intimal proliferation of smooth muscle cells as an explanation for current coronary artery stenosis after percutaneous transluminal coronary angioplasty
    • G. E. Austin, M. B. Ratcliff, and J. Hollman, "Intimal proliferation of smooth muscle cells as an explanation for current coronary artery stenosis after percutaneous transluminal coronary angioplasty," J. Am. Coll. Cardiol. 6, 369-375 (1985).
    • (1985) J. Am. Coll. Cardiol. , vol.6 , pp. 369-375
    • Austin, G.E.1    Ratcliff, M.B.2    Hollman, J.3
  • 2
    • 0024359265 scopus 로고
    • Histopathological phenomena at the site of percutaneous transluminal coronary angioplasty: The problem of restenosis
    • M. B. Gravanis and G. S. Roubin, "Histopathological phenomena at the site of percutaneous transluminal coronary angioplasty: The problem of restenosis," Hum. Pathol. 20, 477-485 (1989).
    • (1989) Hum. Pathol. , vol.20 , pp. 477-485
    • Gravanis, M.B.1    Roubin, G.S.2
  • 3
    • 0021245362 scopus 로고
    • Restenosis after percutaneous transluminal coronary angioplasty (PTCA). A report from the PTCA registry of the National Heart, Lung, and Blood Institute
    • D. R. Holmes et al., "Restenosis after percutaneous transluminal coronary angioplasty (PTCA). A report from the PTCA registry of the National Heart, Lung, and Blood Institute," Am. J. Cardiol. 53, 77-81 (1984).
    • (1984) Am. J. Cardiol. , vol.53 , pp. 77-81
    • Holmes, D.R.1
  • 4
    • 0028625454 scopus 로고
    • Low-dose, β-particle emission from "stent" wire results in complete, localized inhibition of smooth muscle cell proliferation
    • T. A. Fischell, B. K. Kharma, D. R. Fischell, P. G. Loges, C. W. Coffrey, D. M. Duggan, and A. J. Naflilan, "Low-dose, β-particle emission from "stent" wire results in complete, localized inhibition of smooth muscle cell proliferation," Circulation 90, 2956-2963 (1994).
    • (1994) Circulation , vol.90 , pp. 2956-2963
    • Fischell, T.A.1    Kharma, B.K.2    Fischell, D.R.3    Loges, P.G.4    Coffrey, C.W.5    Duggan, D.M.6    Naflilan, A.J.7
  • 5
    • 0029156633 scopus 로고
    • Low-dose radioactive endovascular stents prevent smooth muscle cell proliferation and neointimal hyperplasia
    • C. Hehrlein et al., "Low-dose radioactive endovascular stents prevent smooth muscle cell proliferation and neointimal hyperplasia," Circulation 92, 1570-1575 (1995).
    • (1995) Circulation , vol.92 , pp. 1570-1575
    • Hehrlein, C.1
  • 6
    • 0030204650 scopus 로고    scopus 로고
    • Intravascular radiation for restenosis prevention: Could it be the holy grail?
    • S. B. King III, "Intravascular radiation for restenosis prevention: Could it be the holy grail?," Heart 76, 99-100 (1996).
    • (1996) Heart , vol.76 , pp. 99-100
    • King S.B. III1
  • 7
    • 0030292847 scopus 로고    scopus 로고
    • The potential role of external beam radiation in preventing restenosis after coronary angioplasty
    • W. J. Koh et al., "The potential role of external beam radiation in preventing restenosis after coronary angioplasty," Int. J. Radiat. Oncol., Biol., Phys. 36, 828-834 (1996).
    • (1996) Int. J. Radiat. Oncol., Biol., Phys. , vol.36 , pp. 828-834
    • Koh, W.J.1
  • 9
    • 0030450368 scopus 로고    scopus 로고
    • Vascular irradiation for the prevention of restenosis after angioplasty: A new application for radiotherapy
    • R. Nath and K. B. Roberts, "Vascular irradiation for the prevention of restenosis after angioplasty: A new application for radiotherapy," Int. J. Radiat. Oncol., Biol., Phys. 36, 977-980 (1996).
    • (1996) Int. J. Radiat. Oncol., Biol., Phys. , vol.36 , pp. 977-980
    • Nath, R.1    Roberts, K.B.2
  • 10
    • 0030280622 scopus 로고    scopus 로고
    • 192Ir endovascular brachytherapy for avoidance of intimal hyperplasia after percutaneous transluminal angioplasty and stent implantation in peripheral vessels: 6 years of experience
    • 192Ir endovascular brachytherapy for avoidance of intimal hyperplasia after percutaneous transluminal angioplasty and stent implantation in peripheral vessels: 6 years of experience," Int. J. Radiat. Oncol., Biol., Phys. 36, 835-840 (1996).
    • (1996) Int. J. Radiat. Oncol., Biol., Phys. , vol.36 , pp. 835-840
    • Schopohl, B.1
  • 11
    • 0031005933 scopus 로고    scopus 로고
    • Catheter-based radiotherapy to inhibit restenosis after coronary stenting
    • P. S. Teirstein et al., "Catheter-based radiotherapy to inhibit restenosis after coronary stenting," N. Engl. J. Med. 336, 1697-1703 (1997).
    • (1997) N. Engl. J. Med. , vol.336 , pp. 1697-1703
    • Teirstein, P.S.1
  • 12
    • 0031034495 scopus 로고    scopus 로고
    • Feasibility of intracoronary beta-irradiation to reduce restenosis after balloon angioplasly. A clinical pilot study
    • V. Verin et al., "Feasibility of intracoronary beta-irradiation to reduce restenosis after balloon angioplasly. A clinical pilot study," Circulalion 95, 1138-1144 (1997).
    • (1997) Circulalion , vol.95 , pp. 1138-1144
    • Verin, V.1
  • 14
    • 0029120979 scopus 로고
    • Intracoronary radiation before stent implantation inhibits neointima formation in stented porcine coronary arteries
    • R. Waksman et al., "Intracoronary radiation before stent implantation inhibits neointima formation in stented porcine coronary arteries," Circulation 92, 1383-1386 (1995).
    • (1995) Circulation , vol.92 , pp. 1383-1386
    • Waksman, R.1
  • 16
    • 0027938454 scopus 로고
    • Effects of high-dose intracoronary irradiation on vasomotoric function and smooth muscle histopathology
    • J. G. Wiedemann et al., "Effects of high-dose intracoronary irradiation on vasomotoric function and smooth muscle histopathology," Am. J. Physiol. 267, 125-132 (1994).
    • (1994) Am. J. Physiol. , vol.267 , pp. 125-132
    • Wiedemann, J.G.1
  • 18
    • 0031657316 scopus 로고    scopus 로고
    • Endovascular brachytherapy treatment planning and radiation protection
    • U. Quast, D. Flühs, and M. Bambynek, "Endovascular brachytherapy treatment planning and radiation protection," Herz 23, 337-346 (1998).
    • (1998) Herz , vol.23 , pp. 337-346
    • Quast, U.1    Flühs, D.2    Bambynek, M.3
  • 19
    • 0032941450 scopus 로고    scopus 로고
    • Intravascular brachytherapy physics: Report of the AAPM Radiation Therapy Committee Task Group No. 60
    • R. Nath et al., "Intravascular brachytherapy physics: Report of the AAPM Radiation Therapy Committee Task Group No. 60," Med. Phys. 26, 119-152 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 119-152
    • Nath, R.1
  • 20
    • 0028970569 scopus 로고
    • 90Y brachytherapy: Preliminary dosimetric study using a specially modified angioplasty balloon
    • 90Y brachytherapy: Preliminary dosimetric study using a specially modified angioplasty balloon," Int. J. Radiat. Oncol., Biol., Phys. 33, 713-717 (1995).
    • (1995) Int. J. Radiat. Oncol., Biol., Phys. , vol.33 , pp. 713-717
    • Popowski, Y.1
  • 21
    • 0029867605 scopus 로고    scopus 로고
    • Direct reading measurement of absorbed dose with plastic scintillators - The general concept and applications to ophthalmic dosimetry
    • D. Flühs, M. Heintz, F. Indenkämpen, C. Wieczorek, H. Kolanoski, and U. Quast, "Direct reading measurement of absorbed dose with plastic scintillators - The general concept and applications to ophthalmic dosimetry," Med. Phys. 23, 427-434 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 427-434
    • Flühs, D.1    Heintz, M.2    Indenkämpen, F.3    Wieczorek, C.4    Kolanoski, H.5    Quast, U.6
  • 22
    • 0026804696 scopus 로고
    • Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerations
    • A. S. Beddar, T. R. Mackie, and F. H. Attix, "Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerations," Phys. Med. Biol. 37, 1883-1900 (1992).
    • (1992) Phys. Med. Biol. , vol.37 , pp. 1883-1900
    • Beddar, A.S.1    Mackie, T.R.2    Attix, F.H.3
  • 23
    • 0026793771 scopus 로고
    • Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements
    • A. S. Beddar, T. R. Mackie, and F. H. Attix, "Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements," Phys. Med. Biol. 37, 1901-1913 (1992).
    • (1992) Phys. Med. Biol. , vol.37 , pp. 1901-1913
    • Beddar, A.S.1    Mackie, T.R.2    Attix, F.H.3
  • 24
    • 0025743841 scopus 로고
    • Calibration of ophthalmic applicators at NIST - A revised approach
    • C. G. Soares, "Calibration of ophthalmic applicators at NIST - A revised approach," Med. Phys. 18, 787-793 (1991).
    • (1991) Med. Phys. , vol.18 , pp. 787-793
    • Soares, C.G.1
  • 25
    • 0027169865 scopus 로고
    • Measurement of radial dose distributions around small beta particle emitters using high resolution radiochromic foil dosemeters
    • C. G. Soares and W. L. McLaughlin, "Measurement of radial dose distributions around small beta particle emitters using high resolution radiochromic foil dosemeters," Nuclear Protection Dosimetry 47, 367-372 (1993).
    • (1993) Nuclear Protection Dosimetry , vol.47 , pp. 367-372
    • Soares, C.G.1    McLaughlin, W.L.2
  • 27
    • 0029152039 scopus 로고
    • High dose rate brachytherapy for prevention of restenosis after percutaneous transluminal coronary angiplasty: Preliminary dosimetric tests of a new source presentation
    • Y. Popowski et al., "High dose rate brachytherapy for prevention of restenosis after percutaneous transluminal coronary angiplasty: Preliminary dosimetric tests of a new source presentation," Int. J. Radiat. Oncol., Biol., Phys. 33, 211-215 (1995).
    • (1995) Int. J. Radiat. Oncol., Biol., Phys. , vol.33 , pp. 211-215
    • Popowski, Y.1
  • 28
    • 0030294367 scopus 로고    scopus 로고
    • A novel system for intracoronary bela-irradiation: Description and dosimetric results
    • Y. Popowski et al., "A novel system for intracoronary bela-irradiation: Description and dosimetric results," Int. J. Radiat. Oncol., Biol., Phys. 36, 923-931 (1996).
    • (1996) Int. J. Radiat. Oncol., Biol., Phys. , vol.36 , pp. 923-931
    • Popowski, Y.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.