-
1
-
-
0021062111
-
A protocol for the determination of absorbed dose from high-energy photon and electron beams
-
DOI 10.1118/1.595446
-
AAPM TG-21, " A protocol for the determination of absorbed dose from high-energy photon and electron beams.," Med. Phys. 0094-2405 10, 741-771 (1983). 10.1118/1.595446 (Pubitemid 14216123)
-
(1983)
Medical Physics
, vol.10
, Issue.6
, pp. 741-771
-
-
Schulz, R.J.1
Almond, P.R.2
Cunningham, J.R.3
-
2
-
-
0032874911
-
AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams
-
DOI 10.1118/1.598691
-
P. R. Almond, P. J. Biggs, B. M. Coursey, W. F. Hanson, M. S. Huq, R. Nath, and D. W. O. Rogers, " AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams.," Med. Phys. 0094-2405 26, 1847-1870 (1999). 10.1118/1.598691 (Pubitemid 29442268)
-
(1999)
Medical Physics
, vol.26
, Issue.9
, pp. 1847-1870
-
-
Almond, P.R.1
Biggs, P.J.2
Coursey, B.M.3
Hanson, W.F.4
Huq, M.S.5
Nath, R.6
Rogers, D.W.O.7
-
3
-
-
70349697162
-
-
IAEA, Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water, Technical Report Series Vol. (IAEA, Vienna).
-
IAEA, Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water, Technical Report Series Vol. 398 (IAEA, Vienna, 2001).
-
(2001)
, vol.398
-
-
-
4
-
-
42949146907
-
Calculation of the replacement correction factors for ion chambers in megavoltage beams by Monte Carlo simulation
-
DOI 10.1118/1.2898139
-
L. L. W. Wang and D. W. O. Rogers, " Calculation of the replacement correction factors for ion chambers in megavoltage beams by Monte Carlo simulation.," Med. Phys. 0094-2405 35, 1747-1755 (2008). 10.1118/1.2898139 (Pubitemid 351614788)
-
(2008)
Medical Physics
, vol.35
, Issue.5
, pp. 1747-1755
-
-
Wang, L.L.W.1
Rogers, D.W.O.2
-
5
-
-
63649111792
-
Systematic uncertainties in the Monte Carlo calculation of ion chamber replacement correction factors
-
0094-2405,. 10.1118/1.3115982
-
L. L. W. Wang, D. J. La Russa, and D. W. O. Rogers, " Systematic uncertainties in the Monte Carlo calculation of ion chamber replacement correction factors.," Med. Phys. 0094-2405 36, 1785-1789 (2009). 10.1118/1.3115982
-
(2009)
Med. Phys.
, vol.36
, pp. 1785-1789
-
-
Wang, L.L.W.1
La Russa, D.J.2
Rogers, D.W.O.3
-
6
-
-
63649133736
-
The replacement correction factors for cylindrical chambers in high-energy photon beams
-
0031-9155,. 10.1088/0031-9155/54/6/014
-
L. L. W. Wang and D. W. O. Rogers, " The replacement correction factors for cylindrical chambers in high-energy photon beams.," Phys. Med. Biol. 0031-9155 54, 1609-1620 (2009). 10.1088/0031-9155/54/6/014
-
(2009)
Phys. Med. Biol.
, vol.54
, pp. 1609-1620
-
-
Wang, L.L.W.1
Rogers, D.W.O.2
-
7
-
-
52949085443
-
The replacement correction factor for the BIPM flat cavity ion chamber and the value of W/e
-
0094-2405,. 10.1118/1.2975148
-
L. L. W. Wang and D. W. O. Rogers, " The replacement correction factor for the BIPM flat cavity ion chamber and the value of W/e.," Med. Phys. 0094-2405 35, 4410-4416 (2008). 10.1118/1.2975148
-
(2008)
Med. Phys.
, vol.35
, pp. 4410-4416
-
-
Wang, L.L.W.1
Rogers, D.W.O.2
-
8
-
-
66449086205
-
Study of the effective point of measurement for ion chambers in electron beams by Monte Carlo simulation
-
0094-2405,. 10.1118/1.3121490
-
L. L. W. Wang and D. W. O. Rogers, " Study of the effective point of measurement for ion chambers in electron beams by Monte Carlo simulation.," Med. Phys. 0094-2405 36, 2034-2042 (2009). 10.1118/1.3121490
-
(2009)
Med. Phys.
, vol.36
, pp. 2034-2042
-
-
Wang, L.L.W.1
Rogers, D.W.O.2
-
9
-
-
0000124498
-
Absorbed-dose determination with ionization chambers in electron and photon beams having energies between 1 and 50 MeV
-
(IAEA, Vienna), Paper No. IAEA-SM-222/35
-
K. A. Johansson, L. O. Mattsson, L. Lindborg, and H. Svensson, " Absorbed-dose determination with ionization chambers in electron and photon beams having energies between 1 and 50 MeV.," IAEA Symposium Proceedings (IAEA, Vienna, 1977), Paper No. IAEA-SM-222/35, pp. 243-270.
-
(1977)
IAEA Symposium Proceedings
, pp. 243-270
-
-
Johansson, K.A.1
Mattsson, L.O.2
Lindborg, L.3
Svensson, H.4
-
10
-
-
85027228645
-
-
The EGSnrc code system: Monte Carlo simulation of electron and photon transport," National Research Council of Canada Technical Report No. PIRS-701, (see).
-
I. Kawrakow and D. W. O. Rogers, "The EGSnrc code system: Monte Carlo simulation of electron and photon transport," National Research Council of Canada Technical Report No. PIRS-701, 2000 (see http://www.irs.inms. nrc.ca/inms/irs/EGSnrc/EGSnrc.html).
-
(2000)
-
-
Kawrakow, I.1
Rogers, D.W.O.2
-
11
-
-
0034104708
-
Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version
-
DOI 10.1118/1.598917
-
I. Kawrakow, " Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version.," Med. Phys. 0094-2405 27, 485-498 (2000). 10.1118/1.598917 (Pubitemid 30171797)
-
(2000)
Medical Physics
, vol.27
, Issue.3
, pp. 485-498
-
-
Kawrakow, I.1
-
13
-
-
33746660928
-
-
National Research Council of Canada Technical Report No. PIRS-898, (unpublished).
-
I. Kawrakow, " EGSnrc C ++ class library.," National Research Council of Canada Technical Report No. PIRS-898, 2005 (unpublished) (http://www.irs.inms.nrc.ca/EGSnrc/pirs898/).
-
(2005)
EGSnrc C ++ Class Library
-
-
Kawrakow, I.1
-
14
-
-
52949134962
-
-
National Research Council of Canada Technical Report No. PIRS-899.
-
I. Kawrakow, " egspp: The EGSnrc C ++ class library.," National Research Council of Canada Technical Report No. PIRS-899, 2005.
-
(2005)
Egspp: The EGSnrc C ++ Class Library
-
-
Kawrakow, I.1
-
15
-
-
0030771724
-
Experimental determination of fluence correction factors at depths beyond d(max) for a farmer type cylindrical ionization chamber in clinical electron beams
-
DOI 10.1118/1.597978
-
M. S. Huq, N. Yue, and N. Suntharalingam, " Experimental determination of fluence correction factors at depths beyond dmax for a Farmer type cylindrical ionization chamber in clinical electron beams.," Med. Phys. 0094-2405 24, 1609-1613 (1997). 10.1118/1.597978 (Pubitemid 27449548)
-
(1997)
Medical Physics
, vol.24
, Issue.10
, pp. 1609-1613
-
-
Huq, M.S.1
Yue, N.2
Suntharalingam, N.3
-
16
-
-
58149250375
-
Analysis of dose perturbation factors of a NACP-02 ionization chamber in clinical electron beams
-
0031-9155,. 10.1088/0031-9155/54/2/009
-
E. Chin, H. Palmans, D. Shipley, M. Bailey, and F. Verhaegen, " Analysis of dose perturbation factors of a NACP-02 ionization chamber in clinical electron beams.," Phys. Med. Biol. 0031-9155 54, 307-326 (2009). 10.1088/0031-9155/54/2/009
-
(2009)
Phys. Med. Biol.
, vol.54
, pp. 307-326
-
-
Chin, E.1
Palmans, H.2
Shipley, D.3
Bailey, M.4
Verhaegen, F.5
-
17
-
-
41049084141
-
Q for electron dosimetry with a parallel-plate Roos chamber
-
0031-9155,. 10.1088/0031-9155/53/6/006
-
Q for electron dosimetry with a parallel-plate Roos chamber.," Phys. Med. Biol. 0031-9155 53, 1595-1607 (2008). 10.1088/0031-9155/53/6/006
-
(2008)
Phys. Med. Biol.
, vol.53
, pp. 1595-1607
-
-
Zink, K.1
Wulff, J.2
-
18
-
-
33144474321
-
Perturbation correction factors for the NACP-02 plane-parallel ionization chamber in water in high-energy electron beams
-
DOI 10.1088/0031-9155/51/5/012, PII S0031915506122022
-
F. Verhaegen, R. Zakikhani, A. DuSautoy, H. Palmans, G. Bostock, D. Shipley, and J. Seuntjens, " Perturbation correction factors for the NACP-02 plane-parallel ionization chamber in water in high-energy electron beams.," Phys. Med. Biol. 0031-9155 51, 1221-1235 (2006). 10.1088/0031-9155/51/5/012 (Pubitemid 43267190)
-
(2006)
Physics in Medicine and Biology
, vol.51
, Issue.5
, pp. 1221-1235
-
-
Verhaegen, F.1
Zakikhani, R.2
DuSautoy, A.3
Palmans, H.4
Bostock, G.5
Shipley, D.6
Seuntjens, J.7
-
19
-
-
33744820051
-
wall, for parallel-plate ionization chambers
-
DOI 10.1118/1.2199988
-
L. A. Buckley and D. W. O. Rogers, " Wall correction factors, Pwall, for parallel-plate ionization chambers.," Med. Phys. 0094-2405 33, 1788-1796 (2006). 10.1118/1.2199988 (Pubitemid 43830267)
-
(2006)
Medical Physics
, vol.33
, Issue.6
, pp. 1788-1796
-
-
Buckley, L.A.1
Rogers, D.W.O.2
|