-
3
-
-
0026795831
-
Source configuration and dose rates for the Selectron afterloading equipment for ginecologic applicators
-
0360-3016.
-
P. W. Grigsby, J. F. Williamson, and C. A. Ṕrez, " Source configuration and dose rates for the Selectron afterloading equipment for ginecologic applicators.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 24, 321-327 (1992).
-
(1992)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.24
, pp. 321-327
-
-
Grigsby, P.W.1
Williamson, J.F.2
Ṕrez, C.A.3
-
4
-
-
0012709834
-
-
edited by A. Gerboulet, R. Poetter, J. -J. Mazeron, H. Meertens, and E. Van Limbergen (ESTRO, Leuven).
-
The GEC ESTRO Handbook of Brachytherapy, edited by, A. Gerboulet, R. Poetter, J. -J. Mazeron, H. Meertens, and, E. Van Limbergen, (ESTRO, Leuven, 2002).
-
(2002)
The GEC ESTRO Handbook of Brachytherapy
-
-
-
5
-
-
0014286055
-
The effective attenuation in water of the gamma rays of gold-198, Ir-192, Cs-137, Ra-226, and Co-60
-
0033-8419.
-
L. L. Meisberger, R. J. Keller, and R. J. Shalek, " The effective attenuation in water of the gamma rays of gold-198, Ir-192, Cs-137, Ra-226, and Co-60.," Radiology 0033-8419 90, 953-957 (1968).
-
(1968)
Radiology
, vol.90
, pp. 953-957
-
-
Meisberger, L.L.1
Keller, R.J.2
Shalek, R.J.3
-
6
-
-
0015415155
-
Dose distributions about Cs-137 sources in tissue
-
0033-8419.
-
V. Krishnaswamy, " Dose distributions about Cs-137 sources in tissue.," Radiology 0033-8419 105, 181-184 (1972).
-
(1972)
Radiology
, vol.105
, pp. 181-184
-
-
Krishnaswamy, V.1
-
7
-
-
0023788640
-
Monte Carlo and analytic calculation of absorbed dose near Cs-137 intracavitary sources
-
0360-3016.
-
J. F. Williamson, " Monte Carlo and analytic calculation of absorbed dose near Cs-137 intracavitary sources.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 15, 227-237 (1988).
-
(1988)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.15
, pp. 227-237
-
-
Williamson, J.F.1
-
8
-
-
0024477915
-
137Cs dosimetry table for asymmetric source
-
DOI 10.1118/1.596424
-
R. Waggener, J. Lange, J. Feldmeier, P. Eagan, and S. Martin, " Cs-137 dosimetry table for asymmetric source.," Med. Phys. 0094-2405 16, 305-308 (1989). 10.1118/1.596424 (Pubitemid 19112065)
-
(1989)
Medical Physics
, vol.16
, Issue.2
, pp. 305-308
-
-
Waggener, R.1
Lange, J.2
Feldmeier, J.3
Eagan, P.4
Martin, S.5
-
9
-
-
0031860373
-
137CS tubes
-
DOI 10.1016/S0360-3016(98)00150-3, PII S0360301698001503
-
J. F. Williamson, " Monte Carlo based dose rate tables for the Amersham CDCS.J and 3M Model 6500 Cs-137 tubes.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 41, 959-970 (1998). 10.1016/S0360-3016(98)00150-3 (Pubitemid 28285980)
-
(1998)
International Journal of Radiation Oncology Biology Physics
, vol.41
, Issue.4
, pp. 959-970
-
-
Williamson, J.F.1
-
10
-
-
0028919251
-
Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No.43
-
0094-2405,. 10.1118/1.597458
-
R. Nath, L. L. Anderson, G. Luxton, K. A. Weaver, J. F. Williamson, and A. S. Meigooni, " Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No.43.," Med. Phys. 0094-2405 22, 209-234 (1995). 10.1118/1.597458
-
(1995)
Med. Phys.
, vol.22
, pp. 209-234
-
-
Nath, R.1
Anderson, L.L.2
Luxton, G.3
Weaver, K.A.4
Williamson, J.F.5
Meigooni, A.S.6
-
11
-
-
1142304255
-
Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations
-
0094-2405.
-
M. J. Rivard, B. M. Coursey, L. A. DeWerd, W. F. Hanson, M. Saiful Huq, G. S. Ibbott, M. G. Mitch, R. Nath, and J. F. Williamson, " Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations.," Med. Phys. 0094-2405 31, 663-674 (2004).
-
(2004)
Med. Phys.
, vol.31
, pp. 663-674
-
-
Rivard, M.J.1
Coursey, B.M.2
Dewerd, L.A.3
Hanson, W.F.4
Saiful Huq, M.5
Ibbott, G.S.6
Mitch, M.G.7
Nath, R.8
Williamson, J.F.9
-
12
-
-
0033977992
-
137Cs source
-
DOI 10.1118/1.598875
-
E. Casal, F. Ballester, J. L. Lluch, J. Perez-Calatayud, and F. Lliso, " Monte Carlo calculations of dose rate distribution around the Amersham CDCS-M-type Cs-137 source.," Med. Phys. 0094-2405 27, 132-140 (2000). 10.1118/1.598875 (Pubitemid 30051921)
-
(2000)
Medical Physics
, vol.27
, Issue.1
, pp. 132-140
-
-
Casal, E.1
Ballester, F.2
Lluch, J.L.3
Perez-Calatayud, J.4
Lliso, F.5
-
13
-
-
0033800527
-
137Cs source from CIS
-
DOI 10.1118/1.1289376
-
F. Ballester, J. L. Lluch, Y. Limami, M. A. Serrano, E. Casal, J. Ṕrez-Calatayud, and F. Lliso, " A Monte-Carlo investigation of the dosimetric characteristics of the CSM11 C 137 s source from CIS.," Med. Phys. 0094-2405 27, 2182-2189 (2000). 10.1118/1.1289376 (Pubitemid 30727796)
-
(2000)
Medical Physics
, vol.27
, Issue.9
, pp. 2182-2189
-
-
Ballester, F.1
Lluch, J.L.2
Limami, Y.3
Serrano, M.A.4
Casal, E.5
Perez-Calatayud, J.6
Lliso, F.7
-
14
-
-
0034925104
-
137Cs source
-
DOI 10.1088/0031-9155/46/7/401
-
J. Ṕrez-Calatayud, F. Lliso, F. Ballester, M. A. Serrano, J. L. Lluch, Y. Limami, V. Puchades, and E. Casal, " A Monte-Carlo study of dose rate distributions around the specially asymmetric CSM3-a Cs-137 source.," Phys. Med. Biol. 0031-9155 46, N169-N173 (2001). 10.1088/0031-9155/46/7/401 (Pubitemid 32677557)
-
(2001)
Physics in Medicine and Biology
, vol.46
, Issue.7
-
-
Perez-Calatayud, J.1
Lliso, F.2
Ballester, F.3
Serrano, M.A.4
Lluch, J.L.5
Limami, Y.6
Puchades, V.7
Casal, E.8
-
15
-
-
12844257368
-
Monte Carlo and experimental derivation of TG43 dosimetric parameters for CSM-type Cs-137 sources
-
DOI 10.1118/1.1834835
-
J. Ṕrez-Calatayud, D. Granero, E. Casal, F. Ballester, and V. Puchades, " Monte Carlo and experimental derivation of TG-43 dosimetric parameters for CSM-type Cs-137 sources.," Med. Phys. 0094-2405 32, 28-36 (2005). 10.1118/1.1834835 (Pubitemid 40165512)
-
(2005)
Medical Physics
, vol.32
, Issue.1
, pp. 28-36
-
-
Perez-Calatayud, J.1
Granero, D.2
Casal, E.3
Ballester, F.4
Puchades, V.5
-
16
-
-
0034918042
-
137Cs sources
-
DOI 10.1088/0031-9155/46/7/321
-
J. Ṕrez-Calatayud, F. Ballester, J. L. Lluch, M. A. Serrano-Andŕs, E. Casal, V. Puchades, and Y. Limami, " Monte Carlo calculation of dose rate distributions around the Walstam CDC.K-type C 137 s sources.," Phys. Med. Biol. 0031-9155 46, 2029-2040 (2001). 10.1088/0031-9155/46/7/321 (Pubitemid 32677556)
-
(2001)
Physics in Medicine and Biology
, vol.46
, Issue.7
, pp. 2029-2040
-
-
Perez-Calatayud, J.1
Ballester, F.2
Lluch, J.L.3
Serrano-Andres, M.A.4
Casal, E.5
Puchades, V.6
Limami, Y.7
-
17
-
-
0036118008
-
137Cs brachytherapy sources
-
DOI 10.1118/1.1461844
-
137Cs brachytherapy sources.," Med. Phys. 0094-2405 29, 538-543 (2002). 10.1118/1.1461844 (Pubitemid 34408767)
-
(2002)
Medical Physics
, vol.29
, Issue.4
, pp. 538-543
-
-
Perez-Calatayud, J.1
Ballester, F.2
Serrano-Andres, M.A.3
Lluch, J.L.4
Puchades, V.5
Limami, Y.6
Casal, E.7
-
18
-
-
12144291169
-
Monte Carlo dosimetric characterization of the Cs-137 selectron/LDR source: Evaluation of applicator attenuation and superposition approximation effects
-
DOI 10.1118/1.1644640
-
J. Ṕrez-Calatayud, D. Granero, F. Ballester, V. Puchades, and E. Casal, " Monte Carlo dosimetric characterization of the Cs-137 selectron/LDR source: Evaluation of applicator attenuation and superposition approximation effects.," Med. Phys. 0094-2405 31, 493-499 (2004). 10.1118/1.1644640 (Pubitemid 38381009)
-
(2004)
Medical Physics
, vol.31
, Issue.3
, pp. 493-499
-
-
Perez-Calatayud, J.1
Granero, D.2
Ballester, F.3
Puchades, V.4
Casal, E.5
-
19
-
-
1642311920
-
137Cs dosimetry parameters according to the AAPM TG-43 formalism
-
DOI 10.1118/1.1644519
-
L. Liu, S. C. Prasad, and D. A. Bassano, " Determination of Cs-137 dosimetry parameters according to the AAPM TG-43 formalism.," Med. Phys. 0094-2405 31, 477-483 (2004). 10.1118/1.1644519 (Pubitemid 38381007)
-
(2004)
Medical Physics
, vol.31
, Issue.3
, pp. 477-483
-
-
Liu, L.1
Prasad, S.C.2
Bassano, D.A.3
-
20
-
-
23944487700
-
Technical note: Monte Carlo derivation of TG-43 dosimetric parameters for radiation therapy resources and 3M Cs-137 sources
-
DOI 10.1118/1.1949748
-
J. Ṕrez-Calatayud, D. Granero, F. Ballester, E. Casal, R. Cases, and S. Agramunt, " Technical note: Monte Carlo derivation of TG-43 dosimetric parameters for radiation therapy resources and 3M Cs-137 sources.," Med. Phys. 0094-2405 32, 2464-2470 (2005). 10.1118/1.1949748 (Pubitemid 41197183)
-
(2005)
Medical Physics
, vol.32
, Issue.8
, pp. 2464-2470
-
-
Perez-Calatayud, J.1
Granero, D.2
Ballester, F.3
Casal, E.4
Cases, R.5
Agramunt, S.6
-
22
-
-
0035543812
-
103Pd brachytherapy source
-
DOI 10.1118/1.1414007
-
A. S. Meigooni, Z. Bharucha, M. Yoe-Sein, and K. Sowards, " Dosimetric characteristics of the Best double-wall P 103 d brachytherapy source.," Med. Phys. 0094-2405 28, 2568-2575 (2001). 10.1118/1.1414007 (Pubitemid 34031545)
-
(2001)
Medical Physics
, vol.28
, Issue.12
, pp. 2568-2575
-
-
Meigooni, A.S.1
Bharucha, Z.2
Yoe-Sein, M.3
Sowards, K.4
-
23
-
-
0029003523
-
Instrumentation and dosimeter-size artifacts in quantitative thermoluminescence dosimetry of low-dose fields
-
0094-2405,. 10.1118/1.597555
-
A. S. Meigooni, H. Panth, V. Mishra, and J. F. Williamson, " Instrumentation and dosimeter-size artifacts in quantitative thermoluminescence dosimetry of low-dose fields.," Med. Phys. 0094-2405 22, 555-561 (1995). 10.1118/1.597555
-
(1995)
Med. Phys.
, vol.22
, pp. 555-561
-
-
Meigooni, A.S.1
Panth, H.2
Mishra, V.3
Williamson, J.F.4
-
24
-
-
0038377458
-
Geant4-a simulation toolkit
-
0168-9002, () 10.1016/S0168-9002(03)01368-8; see also.
-
S. Agostinelli, " Geant4-a simulation toolkit.," Nucl. Instrum. Methods Phys. Res. A 0168-9002 506, 250-303 (2003) 10.1016/S0168-9002(03)01368- 8; see also http://geant4.web.cern.ch/geant4/.
-
(2003)
Nucl. Instrum. Methods Phys. Res. A
, vol.506
, pp. 250-303
-
-
Agostinelli, S.1
-
25
-
-
33845939280
-
Dosimetric prerequisites for routine clinical use of photon emitting brachytherapy sources with average energy higher than 50 kev
-
DOI 10.1118/1.2388155
-
Z. Li, R. K. Das, L. A. DeWerd, G. S. Ibbott, A. S. Meigooni, J. Perez-Calatayud, M. J. Rivard, R. S. Sloboda, and J. F. Williamson, " Dosimetric prerequisites for routine clinical use of photon emitting brachytherapy sources with average energy higher than 50 keV.," Med. Phys. 0094-2405 34, 37-40 (2007). 10.1118/1.2388155 (Pubitemid 46035225)
-
(2007)
Medical Physics
, vol.34
, Issue.1
, pp. 37-40
-
-
Li, Z.1
Das, R.K.2
DeWerd, L.A.3
Ibbott, G.S.4
Meigooni, A.S.5
Prez-Calatayud, J.6
Rivard, M.J.7
Sloboda, R.S.8
Williamson, J.F.9
-
26
-
-
70349697159
-
Evaluation of electronic equilibrium conditions near brachytherapy sources
-
0094-2405,. 10.1118/1.2962843
-
J. Perez-Calatayud, D. Granero, M. Rivard, C. Melhus, M. Pujades, and F. Ballester, " Evaluation of electronic equilibrium conditions near brachytherapy sources.," Med. Phys. 0094-2405 35, 2971 (2008). 10.1118/1.2962843
-
(2008)
Med. Phys.
, vol.35
, pp. 2971
-
-
Perez-Calatayud, J.1
Granero, D.2
Rivard, M.3
Melhus, C.4
Pujades, M.5
Ballester, F.6
-
27
-
-
0004007304
-
-
Lawrence Livermore National Laboratory Report No. UCRL-LR-50400, Rev. 5.
-
D. Cullen, J. H. Hubbell and L. Kissel, " EPDL97: The evaluated photon data library, '97 version.," Lawrence Livermore National Laboratory Report No. UCRL-LR-50400, 6, Rev. 5 (1997).
-
(1997)
EPDL97: The Evaluated Photon Data Library, '97 Version
, vol.6
-
-
Cullen, D.1
Hubbell, J.H.2
Kissel, L.3
-
28
-
-
0023514509
-
Monte Carlo evaluation of kerma at a point for photon transport problems
-
DOI 10.1118/1.596069
-
J. F. Williamson, " Monte Carlo evaluation of kerma at a point for photon transport problems.," Med. Phys. 0094-2405 14, 567-576 (1987). 10.1118/1.596069 (Pubitemid 18012507)
-
(1987)
Medical Physics
, vol.14
, Issue.4
, pp. 567-576
-
-
Williamson, J.F.1
-
29
-
-
33750570047
-
103Pd brachytherapy sources
-
DOI 10.1118/1.2357018
-
A. S. Meigooni, S. B. Awan, N. S. Thompson, and S. A. Dini, " Updated Solid Water to water conversion factors for I 125 and P 103 d brachytherapy sources.," Med. Phys. 0094-2405 33, 3988-3992 (2006). 10.1118/1.2357018 (Pubitemid 44673089)
-
(2006)
Medical Physics
, vol.33
, Issue.11
, pp. 3988-3992
-
-
Meigooni, A.S.1
Awan, S.B.2
Thompson, N.S.3
Dini, S.A.4
-
30
-
-
33744798255
-
169Yb sources
-
DOI 10.1118/1.2199987
-
C. S. Melhus and M. J. Rivard, " Approaches to calculating AAPM TG-43 brachytherapy dosimetry parameters for C 137 s, I 125, I 192 r, P 103 d, and Y 169 b sources.," Med. Phys. 0094-2405 33, 1729-1737 (2006). 10.1118/1.2199987 (Pubitemid 43830261)
-
(2006)
Medical Physics
, vol.33
, Issue.6
, pp. 1729-1737
-
-
Melhus, C.S.1
Rivard, M.J.2
-
31
-
-
3142677842
-
Phantom size in brachytherapy source dosimetric studies
-
DOI 10.1118/1.1759826
-
J. Ṕrez-Calatayud, D. Granero, and F. Ballester, " Phantom size in brachytherapy source dosimetric studies.," Med. Phys. 0094-2405 31, 2075-2081 (2004). 10.1118/1.1759826 (Pubitemid 38924828)
-
(2004)
Medical Physics
, vol.31
, Issue.7
, pp. 2075-2081
-
-
Perez-Calatayud, J.1
Granero, D.2
Ballester, F.3
-
32
-
-
25844447703
-
Brachytherapy source characterization for improved dose calculations using primary and scatter dose separation
-
DOI 10.1118/1.1949767
-
K. R. Russell, A. K. Carlsson-Tedgren, and A. Ahnesjö, " Brachytherapy source characterization for improved dose calculations using primary and scatter dose separation.," Med. Phys. 0094-2405 32, 2739-2752 (2005). 10.1118/1.1949767 (Pubitemid 41386556)
-
(2005)
Medical Physics
, vol.32
, Issue.9
, pp. 2739-2752
-
-
Russell, K.R.1
Tedgren, A.K.C.2
Ahnesjo, A.3
-
33
-
-
0025884060
-
A convolution algorithm for brachytherapy dose computation in heterogeneous geometries
-
0094-2405,. 10.1118/1.596601
-
J. F. Williamson, R. S. Baker, and Z. Li, " A convolution algorithm for brachytherapy dose computation in heterogeneous geometries.," Med. Phys. 0094-2405 18, 1256-1265 (1991). 10.1118/1.596601
-
(1991)
Med. Phys.
, vol.18
, pp. 1256-1265
-
-
Williamson, J.F.1
Baker, R.S.2
Li, Z.3
-
34
-
-
54949134922
-
EGSnrc Monte Carlo calculated dosimetry parameters for i 192 r and y 169 b brachytherapy sources
-
0094-2405,. 10.1118/1.2987676
-
R. E. P. Taylor and D. W. O. Rogers, " EGSnrc Monte Carlo calculated dosimetry parameters for I 192 r and Y 169 b brachytherapy sources.," Med. Phys. 0094-2405 35, 4933-4944 (2008). 10.1118/1.2987676
-
(2008)
Med. Phys.
, vol.35
, pp. 4933-4944
-
-
Taylor, R.E.P.1
Rogers, D.W.O.2
-
35
-
-
85027218477
-
-
See EPAPS Document No. E-MPHYA6-36-054910 for the numerical values of the parameters and functions of TG-43 U1 formalism for the IPL in EXCEL spreadsheet format. The primary and scatter photon dose contributions as well as the energy-weighted photon spectrum are also provided. For more information on EPAPS, see http://www.aiorg/pubservs/epaps.html.
-
See EPAPS Document No. E-MPHYA6-36-054910 for the numerical values of the parameters and functions of TG-43 U1 formalism for the IPL in EXCEL spreadsheet format. The primary and scatter photon dose contributions as well as the energy-weighted photon spectrum are also provided. For more information on EPAPS, see http://www.aip.org/pubservs/epaps.html.
-
-
-
|