메뉴 건너뛰기




Volumn 32, Issue 8, 2005, Pages 2464-2470

Technical note: Monte Carlo derivation of TG-43 dosimetric parameters for radiation therapy resources and 3M Cs-137 sources

Author keywords

[No Author keywords available]

Indexed keywords

DOSIMETRY; MONTE CARLO METHODS;

EID: 23944487700     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1949748     Document Type: Article
Times cited : (13)

References (17)
  • 1
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43
    • R. Nath, L. L. Anderson, G. Luxton, K. A. Weaver, J. F. Williamson, and A. S. Meigooni, "Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43," Med. Phys. 22, 209-234 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 209-234
    • Nath, R.1    Anderson, L.L.2    Luxton, G.3    Weaver, K.A.4    Williamson, J.F.5    Meigooni, A.S.6
  • 5
    • 1642311920 scopus 로고    scopus 로고
    • 137Cs dosimetry parameters according to the AAPM TG-43 formalism
    • 137Cs dosimetry parameters according to the AAPM TG-43 formalism," Med. Phys. 31, 477-483 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 477-483
    • Liu, L.1    Prasad, S.C.2    Bassano, D.A.3
  • 6
    • 0038377458 scopus 로고    scopus 로고
    • Geant4 - A simulation toolkit
    • S. Agostinelli et al., "Geant4-A Simulation Toolkit," Nucl. Instrum. Methods Phys. Res. A 506, 250-303 (2003) (see also http://geant4.web. cern.ch/geant4/).
    • (2003) Nucl. Instrum. Methods Phys. Res. A , vol.506 , pp. 250-303
    • Agostinelli, S.1
  • 7
    • 12144291169 scopus 로고    scopus 로고
    • Monte Carlo dosimetric characterization of the Cs-137 selectron/LDR source: Evaluation of applicator attenuation and superposition approximation effects
    • J. Pérez-Calatayud, D. Granero, F. Ballester, V. Puchades, and E. Casal, "Monte Carlo dosimetric characterization of the Cs-137 selectron/LDR source: Evaluation of applicator attenuation and superposition approximation effects," Med. Phys. 31, 493-499 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 493-499
    • Pérez-Calatayud, J.1    Granero, D.2    Ballester, F.3    Puchades, V.4    Casal, E.5
  • 8
    • 11244309250 scopus 로고    scopus 로고
    • Monte Carlo dosimetric study of Best Industries and Alpha Omega Ir-192 brachytherapy seeds
    • F. Ballester, D. Granero, J. Perez-Calatayud, E. Casal, and V. Puchades, "Monte Carlo dosimetric study of Best Industries and Alpha Omega Ir-192 brachytherapy seeds," Med. Phys. 31, 3298-3305 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 3298-3305
    • Ballester, F.1    Granero, D.2    Perez-Calatayud, J.3    Casal, E.4    Puchades, V.5
  • 10
    • 12844257368 scopus 로고    scopus 로고
    • Monte Carlo and experimental derivation of TG43 dosimetric parameters for CSM-type Cs-137 sources
    • J. Pérez-Calatayud, D. Granero, E. Casal, F. Ballester, and V. Puchades, "Monte Carlo and experimental derivation of TG43 dosimetric parameters for CSM-type Cs-137 sources," Med. Phys. 32, 28-36 (2005).
    • (2005) Med. Phys. , vol.32 , pp. 28-36
    • Pérez-Calatayud, J.1    Granero, D.2    Casal, E.3    Ballester, F.4    Puchades, V.5
  • 13
    • 0023514509 scopus 로고
    • Monte Carlo evaluation of kerma at a point for photon transport problems
    • J. F. Williamson, "Monte Carlo evaluation of kerma at a point for photon transport problems," Med. Phys. 14, 567-576 (1987).
    • (1987) Med. Phys. , vol.14 , pp. 567-576
    • Williamson, J.F.1
  • 14
    • 3142677842 scopus 로고    scopus 로고
    • Phantom size in brachytherapy source dosimetric studies
    • J. Pérez-Calatayud, D. Granero, and F. Ballester, "Phantom size in brachytherapy source dosimetric studies," Med. Phys. 31, 2075-2081 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 2075-2081
    • Pérez-Calatayud, J.1    Granero, D.2    Ballester, F.3
  • 15
    • 58149413803 scopus 로고
    • Photon cross sections from 1 keV to 100 MeV for elements Z=1 to Z=100
    • E. Storm and H. I. Israel, "Photon cross sections from 1 keV to 100 MeV for elements Z=1 to Z=100," Nucl. Data Tables A7, 565-681 (1970).
    • (1970) Nucl. Data Tables A , vol.7 , pp. 565-681
    • Storm, E.1    Israel, H.I.2
  • 16
    • 0030442807 scopus 로고    scopus 로고
    • Comparison of x-ray cross sections for diagnostic and therapeutic medical physics
    • J. M. Boone and A. E. Chavez, "Comparison of x-ray cross sections for diagnostic and therapeutic medical physics," Med. Phys. 23, 1997-2005 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 1997-2005
    • Boone, J.M.1    Chavez, A.E.2
  • 17
    • 0032918665 scopus 로고    scopus 로고
    • Review of photon interaction cross sections data in the medical and biological context
    • J. H. Hubbell, "Review of photon interaction cross sections data in the medical and biological context," Phys. Med. Biol. 44, R1-R22 (1999).
    • (1999) Phys. Med. Biol. , vol.44
    • Hubbell, J.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.