Volumn 618 619, Issue , 2009, Pages 303-306

Development of biomedical near β titanium alloys

Author keywords

Bio metal materials; Stent; Surgical implants; Type titanium alloys

Indexed keywords

ALLOYING ELEMENTS; ELASTIC MODULI; HEAT TREATMENT; HIGH STRENGTH ALLOYS; HOT ROLLING; IMPLANTS (SURGICAL); LIGHT METALS; MARTENSITIC TRANSFORMATIONS; METAL IMPLANTS; NIOBIUM ALLOYS; TIN ALLOYS; ZIRCALOY;

EID: 70349500353     PISSN: 02555476     EISSN: 16629752     Source Type: Book Series    
DOI: 10.4028/www.scientific.net/MSF.618-619.303     Document Type: Conference Paper
Times cited : (20)

References (8)
  • 1
    • 0032170254 scopus 로고    scopus 로고
    • Titanium alloys in total joint replacement - a materials science perspective
    • Long, M. and Rack, H. J. (1998) Titanium alloys in total joint replacement - a materials science perspective, Biomaterials 19, 1621-1639
    • (1998) Biomaterials , vol.19 , pp. 1621-1639
    • Long, M.1    Rack, H.J.2
  • 2
    • 0032023387 scopus 로고    scopus 로고
    • Mechanical Properties of biomedical titanium alloys
    • Niinomi, M. (1998) Mechanical Properties of biomedical titanium alloys, Materials Science and Engineering A243, 231-236
    • (1998) Materials Science and Engineering , vol.A243 , pp. 231-236
    • Niinomi, M.1
  • 4
    • 33746759403 scopus 로고    scopus 로고
    • Titanium alloys for biomedical applications
    • Rack, H. J. and Qazi, J.I. (2006) Titanium alloys for biomedical applications, Materials Science and Engineering C26, 1269-1277
    • (2006) Materials Science and Engineering , vol.C26 , pp. 1269-1277
    • Rack, H.J.1    Qazi, J.I.2
  • 5
    • 35048893408 scopus 로고    scopus 로고
    • Niinomi, M. (2008) Mechanical biocompatibilities of titanium alloys for biomedical applications, Journal of Mechanical Behavior of Biomedical Materials 1, 30-42
    • Niinomi, M. (2008) Mechanical biocompatibilities of titanium alloys for biomedical applications, Journal of Mechanical Behavior of Biomedical Materials 1, 30-42
  • 6
    • 12344298672 scopus 로고    scopus 로고
    • Surface modification of titanium, titanium alloys, and related materials for biomedical application
    • Liu, X., Chu, P. K. and Ding, C. (2004) Surface modification of titanium, titanium alloys, and related materials for biomedical application, Materials Science and Engineering R47, 49-121
    • (2004) Materials Science and Engineering , vol.R47 , pp. 49-121
    • Liu, X.1    Chu, P.K.2    Ding, C.3
  • 7
    • 33747608879 scopus 로고    scopus 로고
    • Mechanical compatibility of titanium implants in hard tissues
    • Hanada, S., Matsumoto, H. and Watanabe, W. (2005) Mechanical compatibility of titanium implants in hard tissues, International congress series 1284, 239-247
    • (2005) International congress series , vol.1284 , pp. 239-247
    • Hanada, S.1    Matsumoto, H.2    Watanabe, W.3
  • 8
    • 17044397965 scopus 로고    scopus 로고
    • Designing and development of β type titanium alloy for medical application
    • Yu Z., Zhou L. and Wang, K. (2004) Designing and development of β type titanium alloy for medical application, Rare Metal Letters, 23(1), 5
    • (2004) Rare Metal Letters , vol.23 , Issue.1 , pp. 5
    • Yu, Z.1    Zhou, L.2    Wang, K.3