메뉴 건너뛰기




Volumn 14, Issue 2, 2009, Pages 97-108

Numerical modeling of venturi flows for determining air injection rates using fluent V6.2

Author keywords

Aeration; Air injection; Computational fluid Dynamics; Venturi

Indexed keywords

AIR; COMPUTATION THEORY; HYDRAULICS; NOZZLES; TWO PHASE FLOW; WATER AERATION;

EID: 70349424040     PISSN: 1300686X     EISSN: None     Source Type: Journal    
DOI: 10.3390/mca14020097     Document Type: Article
Times cited : (36)

References (13)
  • 2
    • 0142120465 scopus 로고    scopus 로고
    • Study of the influence of air holes along length of convergent-divergent passage of a venturi device on aeration
    • M. E. Emiroglu and A. Baylar, Study of the influence of air holes along length of convergent-divergent passage of a venturi device on aeration, J. Hydr. Res., 41 (5), 513-520, 2003.
    • (2003) J. Hydr. Res. , vol.41 , Issue.5 , pp. 513-520
    • Emiroglu, M.E.1    Baylar, A.2
  • 4
    • 33745843350 scopus 로고    scopus 로고
    • Applications of venturi principle to water aeration systems
    • A. Baylar and F. Ozkan, Applications of venturi principle to water aeration systems, Environmental Fluid Mechanics, 6 (4), 341-357, 2006.
    • (2006) Environmental Fluid Mechanics , vol.6 , Issue.4 , pp. 341-357
    • Baylar, A.1    Ozkan, F.2
  • 5
    • 34247564484 scopus 로고    scopus 로고
    • Experimental investigations of air and liquid injection by venturi tubes
    • F. Ozkan, M. Ozturk and A. Baylar, Experimental investigations of air and liquid injection by venturi tubes, Water and Environment Journal, 20 (3), 114-122, 2006.
    • (2006) Water and Environment Journal , vol.20 , Issue.3 , pp. 114-122
    • Ozkan, F.1    Ozturk, M.2    Baylar, A.3
  • 6
    • 34247552288 scopus 로고    scopus 로고
    • On the use of venturi tubes in aeration
    • A. Baylar, F. Ozkan and M. Unsal, On the use of venturi tubes in aeration, CLEANSoil, Air, Water, 35 (2), 183-185, 2007.
    • (2007) CLEANSoil, Air, Water , vol.35 , Issue.2 , pp. 183-185
    • Baylar, A.1    Ozkan, F.2    Unsal, M.3
  • 7
    • 34447340886 scopus 로고    scopus 로고
    • Determination of the optimal location of the air hole in venturi aerators
    • A. Baylar, M. Unsal and F. Ozkan, Determination of the optimal location of the air hole in venturi aerators, CLEAN-Soil, Air, Water, 35 (3), 246-249, 2007.
    • (2007) CLEAN-Soil, Air, Water , vol.35 , Issue.3 , pp. 246-249
    • Baylar, A.1    Unsal, M.2    Ozkan, F.3
  • 12
    • 0003977887 scopus 로고    scopus 로고
    • FLUENT 6.2, FLUENT Inc., Lebanon, NH
    • FLUENT 6.2, User's Guide, FLUENT Inc., Lebanon, NH, 2005.
    • (2005) User's Guide
  • 13
    • 70349430369 scopus 로고    scopus 로고
    • GAMBIT 2.2, FLUENT Inc., Lebanon, NH
    • GAMBIT 2.2, Modeling Guide, FLUENT Inc., Lebanon, NH, 2005.
    • (2005) Modeling Guide


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.