메뉴 건너뛰기




Volumn 35, Issue 3, 2007, Pages 246-249

Determination of the optimal location of the air hole in Venturi aerators

Author keywords

Aeration; Air injection; Venturi; Water quality

Indexed keywords

AIR ENTRAINMENT; DISSOLVED OXYGEN; TUBES (COMPONENTS); WATER AERATION; WATER QUALITY; WATER TREATMENT;

EID: 34447340886     PISSN: 18630650     EISSN: None     Source Type: Journal    
DOI: 10.1002/clen.200700026     Document Type: Article
Times cited : (15)

References (9)
  • 3
    • 0142120465 scopus 로고    scopus 로고
    • Study of the Influence of Air Holes along Length of Convergent-Divergent Passage of a Venturi Device on Aeration
    • M. E. Emiroglu, A. Baylar, Study of the Influence of Air Holes along Length of Convergent-Divergent Passage of a Venturi Device on Aeration, J. Hydr. Res. 2003, 41 (5), 513-520.
    • (2003) J. Hydr. Res , vol.41 , Issue.5 , pp. 513-520
    • Emiroglu, M.E.1    Baylar, A.2
  • 4
    • 19044367664 scopus 로고    scopus 로고
    • Influence of Venturi Cone Angles on Jet Aeration Systems
    • A. Baylar, F. Ozkan, M. Ozturk, Influence of Venturi Cone Angles on Jet Aeration Systems, Proc. Inst. Civil Eng.-Water Manag. 2003, 158 (WM1), 9-16.
    • (2003) Proc. Inst. Civil Eng.-Water Manag , vol.158 , Issue.WM1 , pp. 9-16
    • Baylar, A.1    Ozkan, F.2    Ozturk, M.3
  • 5
    • 34247564484 scopus 로고    scopus 로고
    • Experimental Investigations of Air and Liquid Injection by Venturi Tubes
    • F. Ozkan, M. Ozturk, A. Baylar, Experimental Investigations of Air and Liquid Injection by Venturi Tubes, Water Environ. J. 2006, 20 (3), 114-122.
    • (2006) Water Environ. J , vol.20 , Issue.3 , pp. 114-122
    • Ozkan, F.1    Ozturk, M.2    Baylar, A.3
  • 6
    • 33745843350 scopus 로고    scopus 로고
    • Applications of Venturi Principle to Water Aeration Systems
    • A. Baylar, F. Ozkan, Applications of Venturi Principle to Water Aeration Systems. Environ. fluid Mech. 2006, 6 (4), 341-357.
    • (2006) Environ. fluid Mech , vol.6 , Issue.4 , pp. 341-357
    • Baylar, A.1    Ozkan, F.2
  • 7
    • 34247552288 scopus 로고    scopus 로고
    • On the Use of Venturi Tubes in Aeration
    • DOI: 10.1002/ clen.200600025
    • A. Baylar, F. Ozkan, M. Unsal, On the Use of Venturi Tubes in Aeration, Clean 2007, 35 (2), 183-185. DOI: 10.1002/ clen.200600025
    • (2007) Clean , vol.35 , Issue.2 , pp. 183-185
    • Baylar, A.1    Ozkan, F.2    Unsal, M.3
  • 9
    • 34447321966 scopus 로고    scopus 로고
    • ASME Standard MFC-3M-1989, Measurement of Fluid Flow in Pipes Using Orifice, Nozzle and Venturi. ASME, Reaffirmed 1995.
    • ASME Standard MFC-3M-1989, Measurement of Fluid Flow in Pipes Using Orifice, Nozzle and Venturi. ASME, Reaffirmed 1995.