메뉴 건너뛰기




Volumn 51, Issue 1, 2010, Pages 78-83

LCMS using a hybrid quadrupole time of flight mass spectrometer for impurity identification during process chemical development of a novel integrase inhibitor

Author keywords

Impurity identification; LCMS; Process development; QTof; Raltegravir

Indexed keywords

RALTEGRAVIR;

EID: 70349335353     PISSN: 07317085     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jpba.2009.08.007     Document Type: Article
Times cited : (13)

References (12)
  • 1
    • 0347719507 scopus 로고    scopus 로고
    • Searching for scaleable processes: addressing the challenges in times of increasing complexity
    • Federsel H.-J. Searching for scaleable processes: addressing the challenges in times of increasing complexity. Curr. Opin. Drug Disc. Dev. 6 (2003) 838-847
    • (2003) Curr. Opin. Drug Disc. Dev. , vol.6 , pp. 838-847
    • Federsel, H.-J.1
  • 2
    • 0036489215 scopus 로고    scopus 로고
    • Stereoselective synthesis from a process research perspective
    • Hillier M.C., and Reider P.J. Stereoselective synthesis from a process research perspective. Drug Disc. Today 7 (2002) 303-314
    • (2002) Drug Disc. Today , vol.7 , pp. 303-314
    • Hillier, M.C.1    Reider, P.J.2
  • 3
    • 33746914340 scopus 로고    scopus 로고
    • Emerging technologies supporting chemical process R&D and their increasing impact on productivity in the pharmaceutical industry
    • Rubin A.E., Tummala S., Both D.A., Wang C., and Delaney E.J. Emerging technologies supporting chemical process R&D and their increasing impact on productivity in the pharmaceutical industry. Chem. Rev. 106 (2006) 2794-2810
    • (2006) Chem. Rev. , vol.106 , pp. 2794-2810
    • Rubin, A.E.1    Tummala, S.2    Both, D.A.3    Wang, C.4    Delaney, E.J.5
  • 4
    • 15744385431 scopus 로고    scopus 로고
    • Identification of unknown impurities in simvastatin drug substance and tablets by liquid chromatography/tandem mass spectrometry
    • Vuletic M., Cindric M., and Koruznjak J.D. Identification of unknown impurities in simvastatin drug substance and tablets by liquid chromatography/tandem mass spectrometry. J. Pharm. Biomed. Anal. 37 (2005) 715-721
    • (2005) J. Pharm. Biomed. Anal. , vol.37 , pp. 715-721
    • Vuletic, M.1    Cindric, M.2    Koruznjak, J.D.3
  • 5
    • 47349124846 scopus 로고    scopus 로고
    • 4-Hydroxy-5-pyrrolinone-3-carboxamide HIV-1 integrase inhibitors
    • Pace P., Spieser S.A.H., and Summa V. 4-Hydroxy-5-pyrrolinone-3-carboxamide HIV-1 integrase inhibitors. Bioorg. Med. Chem. Lett. 18 (2008) 3865-3869
    • (2008) Bioorg. Med. Chem. Lett. , vol.18 , pp. 3865-3869
    • Pace, P.1    Spieser, S.A.H.2    Summa, V.3
  • 8
    • 36448958008 scopus 로고    scopus 로고
    • The rapid detection and identification of the impurities of simvastatin using high resolution sub 2 μm particle LC coupled to a hybrid time of flight MS operating with alternating high-low collision energy
    • Plumb R.S., Jones M.D., Rainville P., and Castro-Perez J.M. The rapid detection and identification of the impurities of simvastatin using high resolution sub 2 μm particle LC coupled to a hybrid time of flight MS operating with alternating high-low collision energy. J. Sep. Sci. 30 (2007) 2666-2675
    • (2007) J. Sep. Sci. , vol.30 , pp. 2666-2675
    • Plumb, R.S.1    Jones, M.D.2    Rainville, P.3    Castro-Perez, J.M.4
  • 9
    • 0030660309 scopus 로고    scopus 로고
    • The use of liquid chromatography combined with a quadrupole time of flight analyzer for the identification of trace impurities in drug substance
    • Eckers C., Haskins N., and Langridge J. The use of liquid chromatography combined with a quadrupole time of flight analyzer for the identification of trace impurities in drug substance. Rapid Commun. Mass Spectrom. 11 (1997) 1916-1922
    • (1997) Rapid Commun. Mass Spectrom. , vol.11 , pp. 1916-1922
    • Eckers, C.1    Haskins, N.2    Langridge, J.3
  • 10
    • 43549085702 scopus 로고    scopus 로고
    • A sensitive HPLC-MS/MS method for the determination of raltegravir in human plasma
    • Long M.C., Bennetto-Hood C., and Acosta E.P. A sensitive HPLC-MS/MS method for the determination of raltegravir in human plasma. J. Chromatogr. B 867 (2008) 165-171
    • (2008) J. Chromatogr. B , vol.867 , pp. 165-171
    • Long, M.C.1    Bennetto-Hood, C.2    Acosta, E.P.3
  • 11
    • 34548384292 scopus 로고    scopus 로고
    • Determination of the HIV integrase inhibitor, MK-0518 (raltegravir) in human plasma using 96-well liquid-liquid extraction and HPLC-MS/MS
    • Merschman S.A., Vallano P.T., Wenning L.A., Matuszewski B.K., and Woolf E.J. Determination of the HIV integrase inhibitor, MK-0518 (raltegravir) in human plasma using 96-well liquid-liquid extraction and HPLC-MS/MS. J. Chromatogr. B 857 (2007) 15-25
    • (2007) J. Chromatogr. B , vol.857 , pp. 15-25
    • Merschman, S.A.1    Vallano, P.T.2    Wenning, L.A.3    Matuszewski, B.K.4    Woolf, E.J.5
  • 12
    • 43549114496 scopus 로고    scopus 로고
    • Quantification of the HIV-integrase inhibitor raltegravir (MK-0518) in human plasma by high performance liquid chromatography with fluorescence detection
    • Poirier J.-M., Robidou P., and Jaillon P. Quantification of the HIV-integrase inhibitor raltegravir (MK-0518) in human plasma by high performance liquid chromatography with fluorescence detection. J. Chromatogr. B 867 (2008) 277-281
    • (2008) J. Chromatogr. B , vol.867 , pp. 277-281
    • Poirier, J.-M.1    Robidou, P.2    Jaillon, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.