메뉴 건너뛰기




Volumn 21, Issue 2, 2009, Pages 91-96

The fluidhand III: A multifunctional prosthetic hand

Author keywords

Adaptive grasping; Force feedback; Grasp stability; Multifunctional prosthesis; Patient specific control parameters; Prosthetic hand

Indexed keywords


EID: 70349309230     PISSN: 10408800     EISSN: None     Source Type: Journal    
DOI: 10.1097/JPO.0b013e3181a1ca54     Document Type: Conference Paper
Times cited : (63)

References (20)
  • 1
    • 70349368829 scopus 로고
    • The Notebooks of Leonardo da Vinci. London UK: Jonathan Cape
    • MacCurdy E. The Notebooks of Leonardo da Vinci. London, UK: Jonathan Cape; 1977.
    • (1977)
    • MacCurdy, E.1
  • 2
    • 0027723471 scopus 로고
    • A long-term follow-up and a study of the use of alternate prostheses
    • Silcox DH, Rooks MD, Vogel RR, et al. A long-term follow-up and a study of the use of alternate prostheses. J Bone Joint Surg 1993;75:1781-1789.
    • (1993) J Bone Joint Surg , vol.75 , pp. 1781-1789
    • Silcox, D.H.1    Rooks, M.D.2    Vogel, R.R.3
  • 4
    • 34247113256 scopus 로고    scopus 로고
    • Survey of upper extremity prosthesis users in Sweden and the United Kingdom
    • Kyberd PJ, Wartenberg C, SandsjöL, et al. Survey of upper extremity prosthesis users in Sweden and the United Kingdom. J Prosth Ortho 2007;19:55-62.
    • (2007) J Prosth Ortho , vol.19 , pp. 55-62
    • Kyberd, P.J.1    Wartenberg, C.2    Sandsjö, L.3
  • 5
    • 36749101479 scopus 로고    scopus 로고
    • Results of an internet survey of myoelectric prosthetic hand users
    • Pylatiuk C, Schulz S, Döderlein L. Results of an internet survey of myoelectric prosthetic hand users. J Prosth Ortho 2007;31: 362-370.
    • (2007) J Prosth Ortho , vol.31 , pp. 362-370
    • Pylatiuk, C.1    Schulz, S.2    Döderlein, L.3
  • 7
    • 70349364517 scopus 로고    scopus 로고
    • Multi-articulating hands & fingers-technical strategies for improved function and myoelectric uptake
    • Fredericton, Canada, August 13-15
    • Newman PJ. Multi-articulating hands & fingers-technical strategies for improved function and myoelectric uptake. Proceedings of MEC '02, MyoElectric Controls/Powered Prosthetics Symposium. Fredericton, Canada, August 13-15, 2008.
    • (2008) Proceedings of MEC '02, MyoElectric Controls/Powered Prosthetics Symposium
    • Newman, P.J.1
  • 9
    • 4444236525 scopus 로고
    • The Heidelberg pneumatic arm prosthesis
    • Marquart E. The Heidelberg pneumatic arm prosthesis. J Bone Joint Surg 1965;47:425-434.
    • (1965) J Bone Joint Surg , vol.47 , pp. 425-434
    • Marquart, E.1
  • 10
    • 0000719820 scopus 로고
    • A comparative analysis of actuator technologies for robotics
    • Khatib O, Craig J, Lozano-Perez T, eds. Cambridge, MA: MIT Press
    • Hollerbach JM, Hunter IW, Ballantyne J. A comparative analysis of actuator technologies for robotics. In: Khatib O, Craig J, Lozano-Perez T, eds. The Robotics Review 2. Cambridge, MA: MIT Press; 1992:299-342.
    • (1992) The Robotics Review 2 , pp. 299-342
    • Hollerbach, J.M.1    Hunter, I.W.2    Ballantyne, J.3
  • 11
    • 38349184785 scopus 로고    scopus 로고
    • Development of a miniaturised hydraulic actuation system for artificial hands
    • Kargov A, Pylatiuk C, Schulz S. Development of a miniaturised hydraulic actuation system for artificial hands. Sensors Actuators A: Phys 2007;141:548-557.
    • (2007) Sensors Actuators A: Phys , vol.141 , pp. 548-557
    • Kargov, A.1    Pylatiuk, C.2    Schulz, S.3
  • 15
    • 77957802846 scopus 로고    scopus 로고
    • Robust training and control strategies fort he grasp type selection of hand prostheses
    • Heidelberg, Germany, September 12-14
    • Reischl M, Mikut R, Bretthauer G. Robust training and control strategies fort he grasp type selection of hand prostheses. In: Proceedings of the IFAC Symposium on Mechatronic Systems. Heidelberg, Germany, September 12-14, 2006.
    • (2006) Proceedings of the IFAC Symposium on Mechatronic Systems
    • Reischl, M.1    Mikut, R.2    Bretthauer, G.3
  • 17
    • 33749435189 scopus 로고    scopus 로고
    • Design and evaluation of a low-cost force feedback system for myoelectric prosthetic hands
    • Pylatiuk C, Kargov A, Schulz S. Design and evaluation of a low-cost force feedback system for myoelectric prosthetic hands. JPO J Prosth Ortho 2006;18:362-370.
    • (2006) JPO J Prosth Ortho , vol.18 , pp. 362-370
    • Pylatiuk, C.1    Kargov, A.2    Schulz, S.3
  • 18
    • 18844461271 scopus 로고    scopus 로고
    • A hydraulically driven multifunctional prosthetic hand.
    • Schulz S, Pylatiuk C, Reischl M, et al. A hydraulically driven multifunctional prosthetic hand. Robotica 2005;23:293-299.
    • (2005) Robotica , vol.23 , pp. 293-299
    • Schulz, S.1    Pylatiuk, C.2    Reischl, M.3
  • 19
    • 3042858375 scopus 로고    scopus 로고
    • A comparison of the grip force distribution in natural hands and in prosthetic hands
    • Kargov A, Pylatiuk C, Martin J, et al. A comparison of the grip force distribution in natural hands and in prosthetic hands. Disability Rehabil 2008;26:705-711.
    • (2008) Disability Rehabil , vol.26 , pp. 705-711
    • Kargov, A.1    Pylatiuk, C.2    Martin, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.