메뉴 건너뛰기




Volumn 19, Issue 16, 2009, Pages 2592-2600

Ferroelectric response and induced biaxiality in the nematic phase of a bent-core mesogen

Author keywords

[No Author keywords available]

Indexed keywords

AT COMMAND; BIAXIALITY; CURRENT MEASUREMENTS; ELECTRO-OPTICAL; ELECTROOPTIC DEVICES; EXPERIMENTAL EVIDENCE; EXTERNAL ELECTRIC FIELD; FERROELECTRIC RESPONSE; FERROELECTRIC SMECTIC; FERROELECTRIC SWITCHING; MESOGENES; NEMATIC PHASE; POLAR MOLECULES; REPOLARIZATION;

EID: 70349242175     PISSN: 1616301X     EISSN: 16163028     Source Type: Journal    
DOI: 10.1002/adfm.200801865     Document Type: Article
Times cited : (186)

References (63)
  • 24
    • 70349234130 scopus 로고    scopus 로고
    • In Ref. [23], based solely on preliminary x-ray diffraction measurements on unoriented powder, the smectic phase of 9BPO was assigned SmA instead of SmC
    • In Ref. [23], based solely on preliminary x-ray diffraction measurements on unoriented powder, the smectic phase of 9BPO was assigned SmA instead of SmC.
  • 27
    • 70349231114 scopus 로고
    • (Eds: G. W. Gray, P. Winsor), Ellis Horwood, Chichester, UK
    • J. Falguirettes, P. Delord, in: Liquid Crystals and Plastic Crystals, Vol.1, (Eds: G. W. Gray, P. Winsor), Ellis Horwood, Chichester, UK 1974, pp.62-79.
    • (1974) Liquid Crystals and Plastic Crystals , vol.1 , pp. 62-79
    • Falguirettes, J.1    Delord, P.2
  • 32
    • 70349248016 scopus 로고    scopus 로고
    • MD is estimated from the distribution of the largest dimension of the minimum volume box containing the molecule rotated in its inertial frame, obtained from the atomistic MD simulation at 227°C described in the experimental and Supporting Information sections
    • MD is estimated from the distribution of the largest dimension of the minimum volume box containing the molecule rotated in its inertial frame, obtained from the atomistic MD simulation at 227°C described in the experimental and Supporting Information sections.
  • 50
    • 70349245018 scopus 로고    scopus 로고
    • To compare the experimental and theoretical polarization values, a scaling factor was required and thus we have scaled the value at 190° C in Figure 3B to the experimental one, but otherwise no fitting has been performed
    • To compare the experimental and theoretical polarization values, a scaling factor was required and thus we have scaled the value at 190° C in Figure 3B to the experimental one, but otherwise no fitting has been performed.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.