메뉴 건너뛰기




Volumn 171, Issue 1-3, 2009, Pages 601-605

Design of a novel optical sensor for determination of trace gadolinium

Author keywords

Bis(thiophenal) pyridine 2,6 diamine; Gadolinium; Optical sensor; River water; Triacetylcellulose

Indexed keywords

BIS(THIOPHENAL) PYRIDINE-2,6-DIAMINE; CERTIFIED REFERENCE MATERIALS; DETECTION LIMITS; FAST RESPONSE TIME; ION CONCENTRATIONS; LANTHANIDE ION; LINEAR RANGE; LOW DETECTION LIMIT; RESPONSE TIME; RIVER WATER; SOLUTION PH; TRIACETYLCELLULOSE; WATER SAMPLES;

EID: 70349241568     PISSN: 03043894     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jhazmat.2009.06.044     Document Type: Article
Times cited : (47)

References (34)
  • 3
    • 33645766062 scopus 로고    scopus 로고
    • Inductively coupled plasma optical emission spectrometric determination of gadolinium in urine using flow injection on-line sorption preconcentration in a knotted reactor
    • Salonia J.A., Gasquez J.A., Martinez L.D., Cerutti S., Kaplan M., and Olsina R.A. Inductively coupled plasma optical emission spectrometric determination of gadolinium in urine using flow injection on-line sorption preconcentration in a knotted reactor. Instrum. Sci. Technol. 34 (2006) 305-316
    • (2006) Instrum. Sci. Technol. , vol.34 , pp. 305-316
    • Salonia, J.A.1    Gasquez, J.A.2    Martinez, L.D.3    Cerutti, S.4    Kaplan, M.5    Olsina, R.A.6
  • 4
    • 26844565163 scopus 로고    scopus 로고
    • Investigations for determination of Gd and Sm isotopic compositions in spent nuclear fuels samples by MC ICP-MS
    • Isnard H., Brennetot R., Caussignac C., Caussignac N., and Chartier F. Investigations for determination of Gd and Sm isotopic compositions in spent nuclear fuels samples by MC ICP-MS. Int. J. Mass Spectrom. 246 (2005) 66-73
    • (2005) Int. J. Mass Spectrom. , vol.246 , pp. 66-73
    • Isnard, H.1    Brennetot, R.2    Caussignac, C.3    Caussignac, N.4    Chartier, F.5
  • 5
    • 2142704281 scopus 로고    scopus 로고
    • Determination of gadolinium in river water by SPE preconcentration and ICP-MS
    • Hennebruder K., Wennrich R., Mattusch J., Stark H.J., and Engewald W. Determination of gadolinium in river water by SPE preconcentration and ICP-MS. Talanta 63 (2004) 309-316
    • (2004) Talanta , vol.63 , pp. 309-316
    • Hennebruder, K.1    Wennrich, R.2    Mattusch, J.3    Stark, H.J.4    Engewald, W.5
  • 6
    • 0032965111 scopus 로고    scopus 로고
    • Determination of rare earth impurities in high purity gadolinium oxide by inductively coupled plasma mass spectrometry after 2-ethylhexylhydrogen-ethylhexy phosphonate extraction chromatographic separation
    • Cao X., Yin M., and Li B. Determination of rare earth impurities in high purity gadolinium oxide by inductively coupled plasma mass spectrometry after 2-ethylhexylhydrogen-ethylhexy phosphonate extraction chromatographic separation. Talanta 48 (1999) 517-525
    • (1999) Talanta , vol.48 , pp. 517-525
    • Cao, X.1    Yin, M.2    Li, B.3
  • 7
    • 34547704365 scopus 로고
    • Determination of gadolinium in geological samples by inductively coupled plasma mass spectrometry and multivariate calibration
    • Behrens A. Determination of gadolinium in geological samples by inductively coupled plasma mass spectrometry and multivariate calibration. Spectrochim. Acta B 50 (1995) 1521-1530
    • (1995) Spectrochim. Acta B , vol.50 , pp. 1521-1530
    • Behrens, A.1
  • 8
    • 0034114164 scopus 로고    scopus 로고
    • Quantification of gadodiamide as Gd in serum, peritoneal dialysate and faeces by inductively coupled plasma atomic emission spectroscopy and comparative analysis by high-performance liquid chromatography
    • Normann P.T., Joff P., Martinsen I., and Thomsen H.S. Quantification of gadodiamide as Gd in serum, peritoneal dialysate and faeces by inductively coupled plasma atomic emission spectroscopy and comparative analysis by high-performance liquid chromatography. J. Pharm. Biomed. Anal. 22 (2000) 939-947
    • (2000) J. Pharm. Biomed. Anal. , vol.22 , pp. 939-947
    • Normann, P.T.1    Joff, P.2    Martinsen, I.3    Thomsen, H.S.4
  • 9
    • 34547695633 scopus 로고
    • 2 solid solution by electron spin resonance, X-ray photoelectron spectroscopy and magnetic susceptibility
    • 2 solid solution by electron spin resonance, X-ray photoelectron spectroscopy and magnetic susceptibility. J. Less Common Met. 121 (1986) 261-264
    • (1986) J. Less Common Met. , vol.121 , pp. 261-264
    • Miyake, C.1    Imoto, S.2
  • 11
    • 0014603701 scopus 로고
    • Evaluation of electron spin resonance for quantitative determinations of gadolinium, chromium, iron, copper and manganese
    • Moyer S., and McCarthy W.J. Evaluation of electron spin resonance for quantitative determinations of gadolinium, chromium, iron, copper and manganese. Anal. Chim. Acta 48 (1969) 79-85
    • (1969) Anal. Chim. Acta , vol.48 , pp. 79-85
    • Moyer, S.1    McCarthy, W.J.2
  • 12
    • 0036013840 scopus 로고    scopus 로고
    • Trace determination of gadolinium in biomedical samples by diode-laser-based multi-step resonance ionization mass spectrometry
    • Blaum K., Geppert C., Schreiber W., Hengstler J., Muller P., Nortershauser W., Wendt K., and Bushaw B. Trace determination of gadolinium in biomedical samples by diode-laser-based multi-step resonance ionization mass spectrometry. Anal. Bioanal. Chem. 372 (2002) 759-765
    • (2002) Anal. Bioanal. Chem. , vol.372 , pp. 759-765
    • Blaum, K.1    Geppert, C.2    Schreiber, W.3    Hengstler, J.4    Muller, P.5    Nortershauser, W.6    Wendt, K.7    Bushaw, B.8
  • 13
    • 0003008828 scopus 로고    scopus 로고
    • Room temperature phosphorescence optosensing for gadolinium
    • Gong Z., and Zhang Z. Room temperature phosphorescence optosensing for gadolinium. Mikrochim. Acta 126 (1997) 117-121
    • (1997) Mikrochim. Acta , vol.126 , pp. 117-121
    • Gong, Z.1    Zhang, Z.2
  • 14
    • 27844455001 scopus 로고
    • Determination of gadolinium in aquous solutions by time-resolved fluorimetry
    • Berg B., Mainka E., and Ache H.J. Determination of gadolinium in aquous solutions by time-resolved fluorimetry. Anal. Bioanal. Chem. 333 (1989) 766-767
    • (1989) Anal. Bioanal. Chem. , vol.333 , pp. 766-767
    • Berg, B.1    Mainka, E.2    Ache, H.J.3
  • 15
    • 0017899139 scopus 로고
    • Spectrophotofluorimetric determination of gadolinium with triethylenetetramine-n,n,n,'n',n‴,n‴-hexaacetic acid
    • Taketatsu T., and Sato A. Spectrophotofluorimetric determination of gadolinium with triethylenetetramine-n,n,n,'n',n‴,n‴-hexaacetic acid. Anal. Chim. Acta 98 (1978) 397-399
    • (1978) Anal. Chim. Acta , vol.98 , pp. 397-399
    • Taketatsu, T.1    Sato, A.2
  • 16
    • 0000223482 scopus 로고
    • Determination of gadolinium in sodium borate glasses
    • Reisfeld R., and Biron E. Determination of gadolinium in sodium borate glasses. Talanta 17 (1970) 105-108
    • (1970) Talanta , vol.17 , pp. 105-108
    • Reisfeld, R.1    Biron, E.2
  • 19
    • 28844436065 scopus 로고    scopus 로고
    • A new pentadentate S-N Schiffs' base as a novel ionophore in construction of a novel Gd(III) membrane sensor
    • Ganjali M.R., Rezapour M., Norouzi P., and Salavati-Niasari M. A new pentadentate S-N Schiffs' base as a novel ionophore in construction of a novel Gd(III) membrane sensor. Electroanalysis 17 (2005) 2032-2036
    • (2005) Electroanalysis , vol.17 , pp. 2032-2036
    • Ganjali, M.R.1    Rezapour, M.2    Norouzi, P.3    Salavati-Niasari, M.4
  • 20
    • 33845635582 scopus 로고    scopus 로고
    • Fabrication of a highly selective and sensitive Gd(III)-PVC membrane sensor based on N-(2-pyridyl)-N′-(4-nitrophenyl)thiourea
    • Ganjali M.R., Norouzi P., Alizadeh T., Tajarodi A., and Hanifehpour Y. Fabrication of a highly selective and sensitive Gd(III)-PVC membrane sensor based on N-(2-pyridyl)-N′-(4-nitrophenyl)thiourea. Sens. Actuators B 120 (2007) 487-493
    • (2007) Sens. Actuators B , vol.120 , pp. 487-493
    • Ganjali, M.R.1    Norouzi, P.2    Alizadeh, T.3    Tajarodi, A.4    Hanifehpour, Y.5
  • 21
    • 34547678005 scopus 로고    scopus 로고
    • Determination of gadolinium(III) ions in soil and sediment samples by a novel gadolinium membrane sensor based on 6-methyl-4-{[1-(2-thienyl)methylidene]amino}3-thioxo-3,4-dihydro-1,2,4-triazin-5-(2H)-one
    • Zamani H.A., Rajabzadeh G., Ganjali M.R., and Norouzi P. Determination of gadolinium(III) ions in soil and sediment samples by a novel gadolinium membrane sensor based on 6-methyl-4-{[1-(2-thienyl)methylidene]amino}3-thioxo-3,4-dihydro-1,2,4-triazin-5-(2H)-one. Anal. Chim. Acta 598 (2007) 51-57
    • (2007) Anal. Chim. Acta , vol.598 , pp. 51-57
    • Zamani, H.A.1    Rajabzadeh, G.2    Ganjali, M.R.3    Norouzi, P.4
  • 22
    • 34547721367 scopus 로고
    • Precision determination of gadolinium in cadmium fluoride by neutron activation analysis
    • Marsh R.H., and Allie W. Precision determination of gadolinium in cadmium fluoride by neutron activation analysis. Anal. Chim. Acta 45 (1969) 179-182
    • (1969) Anal. Chim. Acta , vol.45 , pp. 179-182
    • Marsh, R.H.1    Allie, W.2
  • 23
    • 41449105932 scopus 로고    scopus 로고
    • Removal of lanthanum and gadolinium from nitrate medium using Aliquat-336 impregnated onto Amberlite XAD-4
    • El-Sofany E.A. Removal of lanthanum and gadolinium from nitrate medium using Aliquat-336 impregnated onto Amberlite XAD-4. J. Hazard. Mater. 153 (2008) 948-954
    • (2008) J. Hazard. Mater. , vol.153 , pp. 948-954
    • El-Sofany, E.A.1
  • 24
    • 44449085955 scopus 로고    scopus 로고
    • Gadolinium hydroxide coprecipitation system for the separation-preconcentration of some heavy metals
    • Soylak M., and Balgunes H. Gadolinium hydroxide coprecipitation system for the separation-preconcentration of some heavy metals. J. Hazard. Mater. 155 (2008) 595-600
    • (2008) J. Hazard. Mater. , vol.155 , pp. 595-600
    • Soylak, M.1    Balgunes, H.2
  • 26
    • 60549090861 scopus 로고    scopus 로고
    • Design of a Novel gadolinium optical sensor based on immobilization of (Z)-N′-((pyridine-2-yl) methylene) thiophene-2-carbohydrazide on a triacetylcellulose membrane and its application to the urine samples
    • Zare-Dorabei R., Norouzi P., and Ganjali M.R. Design of a Novel gadolinium optical sensor based on immobilization of (Z)-N′-((pyridine-2-yl) methylene) thiophene-2-carbohydrazide on a triacetylcellulose membrane and its application to the urine samples. Anal. Lett. 42 (2009) 190-203
    • (2009) Anal. Lett. , vol.42 , pp. 190-203
    • Zare-Dorabei, R.1    Norouzi, P.2    Ganjali, M.R.3
  • 28
    • 44949240615 scopus 로고    scopus 로고
    • Design of an optical sensor for indirect determination of isoniazid
    • Safavi A., and Bagheri M. Design of an optical sensor for indirect determination of isoniazid. Spectrochim. Acta A 70 (2008) 735-739
    • (2008) Spectrochim. Acta A , vol.70 , pp. 735-739
    • Safavi, A.1    Bagheri, M.2
  • 29
    • 42049084851 scopus 로고    scopus 로고
    • Diphenylthiocarbazone immobilized on the triacetyl cellulose membrane as an optical silver sensor
    • Noroozifar M., Khorasani Motlagh M., Taheri A., and Zare-Dorabei R. Diphenylthiocarbazone immobilized on the triacetyl cellulose membrane as an optical silver sensor. Turk. J. Chem. 32 (2008) 249-257
    • (2008) Turk. J. Chem. , vol.32 , pp. 249-257
    • Noroozifar, M.1    Khorasani Motlagh, M.2    Taheri, A.3    Zare-Dorabei, R.4
  • 30
    • 0026630286 scopus 로고
    • Theoretical aspects of bulk optode membranes
    • Seiler K., and Simon W. Theoretical aspects of bulk optode membranes. Anal. Chim. Acta 266 (1992) 73-78
    • (1992) Anal. Chim. Acta , vol.266 , pp. 73-78
    • Seiler, K.1    Simon, W.2
  • 31
    • 0001083842 scopus 로고    scopus 로고
    • Optical sensors for determination of heavy metal ions
    • Oehme I., and Wolfbeis O.S. Optical sensors for determination of heavy metal ions. Mikrochim. Acta 126 (1997) 177-192
    • (1997) Mikrochim. Acta , vol.126 , pp. 177-192
    • Oehme, I.1    Wolfbeis, O.S.2
  • 32
    • 0023977783 scopus 로고
    • Optical pH sensors based on the chemical modification of a porous polymer film
    • Jones T.P., and Porter M.D. Optical pH sensors based on the chemical modification of a porous polymer film. Anal. Chem. 60 (1988) 404-406
    • (1988) Anal. Chem. , vol.60 , pp. 404-406
    • Jones, T.P.1    Porter, M.D.2
  • 33
    • 0033068897 scopus 로고    scopus 로고
    • Characterisation of Hg(II) ion optrode based on nafion-1-(2-thiazolylazo)-2-7 naphthol composite thin films
    • Kuswandi B., and Narayanaswamy R. Characterisation of Hg(II) ion optrode based on nafion-1-(2-thiazolylazo)-2-7 naphthol composite thin films. J. Environ. Monit. 1 (1999) 109-114
    • (1999) J. Environ. Monit. , vol.1 , pp. 109-114
    • Kuswandi, B.1    Narayanaswamy, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.