메뉴 건너뛰기




Volumn 49, Issue 14, 2004, Pages

MCDE: A new Monte Carlo dose engine for IMRT

Author keywords

[No Author keywords available]

Indexed keywords

DOSE ENGINE; ELECTRON TRANSPORT; LINEAR ACCELERATOR;

EID: 4344664695     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/49/14/N04     Document Type: Article
Times cited : (27)

References (20)
  • 2
    • 0035479178 scopus 로고    scopus 로고
    • An implementation strategy for IMRT of ethmoid sinus cancer with bilateral sparing of the optic pathways
    • Claus F et al 2001 An implementation strategy for IMRT of ethmoid sinus cancer with bilateral sparing of the optic pathways Int. J. Radiat. Oncol. Biol. Phys. 51 318-31
    • (2001) Int. J. Radiat. Oncol. Biol. Phys. , vol.51 , pp. 318-331
    • Claus, F.1
  • 3
    • 0032860849 scopus 로고    scopus 로고
    • Dose measurements compared with Monte Carlo simulations of narrow 6 MV multileaf collimator shaped photon beams
    • De Vlamynck K, Palmans H, Verhaegen F, De Wagter C, De Neve W and Thierens H 1999 Dose measurements compared with Monte Carlo simulations of narrow 6 MV multileaf collimator shaped photon beams Med. Phys. 26 1874-82
    • (1999) Med. Phys. , vol.26 , pp. 1874-1882
    • De Vlamynck, K.1    Palmans, H.2    Verhaegen, F.3    De Wagter, C.4    De Neve, W.5    Thierens, H.6
  • 4
    • 0032772588 scopus 로고    scopus 로고
    • Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm
    • Fippel M 1999 Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm Med. Phys. 26 1466-75
    • (1999) Med. Phys. , vol.26 , pp. 1466-1475
    • Fippel, M.1
  • 5
    • 0033866920 scopus 로고    scopus 로고
    • Photon dose calculations of a three-dimensional treatment planning system compared to the Monte Carlo code BEAM
    • Francescon P, Cavedon C and Reccanello Cora S 2000 Photon dose calculations of a three-dimensional treatment planning system compared to the Monte Carlo code BEAM Med. Phys. 27 1579-87
    • (2000) Med. Phys. , vol.27 , pp. 1579-1587
    • Francescon, P.1    Cavedon, C.2    Reccanello, C.S.3
  • 6
    • 0003797114 scopus 로고    scopus 로고
    • The EGSnrc code system: Monte Carlo simulation of electron and photon transport
    • National Research Council of Canada, Ottawa
    • Kawrakow I and Rogers D W O 2000 The EGSnrc code system: Monte Carlo simulation of electron and photon transport NRCC Report PIRS-701 National Research Council of Canada, Ottawa
    • (2000) NRCC Report PIRS-701
    • Kawrakow, I.1    Rogers, D.W.O.2
  • 7
    • 0033781481 scopus 로고    scopus 로고
    • Validation of a Monte Carlo dose calculation tool for radiotherapy treatment planning
    • Li J S, Pawlicki T, Deng J, Jiang S B, Mok E and Ma C-M 2000 Validation of a Monte Carlo dose calculation tool for radiotherapy treatment planning Phys. Med. Biol. 45 2969-85
    • (2000) Phys. Med. Biol. , vol.45 , pp. 2969-2985
    • Li, J.S.1    Pawlicki, T.2    Deng, J.3    Jiang, S.B.4    Mok, E.5    Ma, C.-M.6
  • 9
    • 0035996450 scopus 로고    scopus 로고
    • Underdosage of the upper-airway mucosa for small fields as used in intensity-modulated radiation therapy: A comparison between radiochromic film measurements, Monte Carlo simulations, and collapsed cone convolution calculations
    • Martens C, Reynaert N, De Wagter C, Nilsson P, Coghe M, Palmans H, Thierens H and De Neve W 2002 Underdosage of the upper-airway mucosa for small fields as used in intensity-modulated radiation therapy: a comparison between radiochromic film measurements, Monte Carlo simulations, and collapsed cone convolution calculations Med. Phys. 29 1528-35
    • (2002) Med. Phys. , vol.29 , pp. 1528-1535
    • Martens, C.1    Reynaert, N.2    De Wagter, C.3    Nilsson, P.4    Coghe, M.5    Palmans, H.6    Thierens, H.7    De Neve, W.8
  • 13
    • 0028953755 scopus 로고
    • MMC - A high-performance Monte Carlo code for electron beam treatment planning
    • Neuenschwander H, Mackie T R and Reckwerdt P J 1995 MMC - a high-performance Monte Carlo code for electron beam treatment planning Phys. Med. Biol. 40 543-74
    • (1995) Phys. Med. Biol. , vol.40 , pp. 543-574
    • Neuenschwander, H.1    Mackie, T.R.2    Reckwerdt, P.J.3
  • 16
    • 0342748359 scopus 로고    scopus 로고
    • Patient-dependent beam-modifier physics in Monte Carlo photon dose calculations
    • Schach von Wittenau A E, Bergstrom R M and Cox L J 2000 Patient-dependent beam-modifier physics in Monte Carlo photon dose calculations Med. Phys. 27 935-47
    • (2000) Med. Phys. , vol.27 , pp. 935-947
    • Schach von Wittenau, A.E.1    Bergstrom, R.M.2    Cox, L.J.3
  • 17
    • 0033983759 scopus 로고    scopus 로고
    • Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions
    • Schneider W, Bortfield T and Schlegel W 2000 Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions Phys. Med. Biol. 45 459-78
    • (2000) Phys. Med. Biol. , vol.45 , pp. 459-478
    • Schneider, W.1    Bortfield, T.2    Schlegel, W.3
  • 20
    • 0031858002 scopus 로고    scopus 로고
    • A patient-specific Monte Carlo dose-calculation method for photon beams
    • Wang L, Chen-Shou Ch and Lovelock M 1998 A patient-specific Monte Carlo dose-calculation method for photon beams Med. Phys. 25 867-78
    • (1998) Med. Phys. , vol.25 , pp. 867-878
    • Wang, L.1    Chen-Shou, Ch.2    Lovelock, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.