메뉴 건너뛰기




Volumn 42, Issue 15, 2009, Pages 1531-1542

Drugs of abuse testing by tandem mass spectrometry: A rapid, simple method to replace immunoassays

Author keywords

Chromatography; Drugs of abuse; GC MS; Screening; Tandem mass spectrometry; Toxicology; UPLC

Indexed keywords

3,4 METHYLENEDIOXYAMPHETAMINE; 7 AMINOFLUNITRAZEPAM; ALPRAZOLAM; AMPHETAMINE; AMPHETAMINE DERIVATIVE; CLONAZEPAM; COCAINE; DIAZEPAM; DIPHENHYDRAMINE; FENTANYL; FLUNITRAZEPAM; FLURAZEPAM; HYDROMORPHONE; KETAMINE; LORAZEPAM; LYSERGIDE; METHYLPHENIDATE; MORPHINE; MORPHINE 6 ACETATE; MORPHINE DERIVATIVE; N ETHYL 3,4 METHYLENEDIOXYAMPHETAMINE; NORDAZEPAM; OXAZEPAM; OXYCODONE; PETHIDINE; PSEUDOEPHEDRINE; RITALINIC ACID; TEMAZEPAM; TRIAZOLAM;

EID: 70249127173     PISSN: 00099120     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clinbiochem.2009.07.019     Document Type: Article
Times cited : (62)

References (19)
  • 2
    • 33748528614 scopus 로고    scopus 로고
    • Comparison of urine and oral fluid as matrices for screening of thirty-three benzodiazepines and benzodiazepine-like substances using immunoassay and LC-MS(-MS)
    • Smink B.E., Mathijssen M.P., Lusthof K.J., et al. Comparison of urine and oral fluid as matrices for screening of thirty-three benzodiazepines and benzodiazepine-like substances using immunoassay and LC-MS(-MS). J. Anal. Toxicol. 30 (2006) 478-485
    • (2006) J. Anal. Toxicol. , vol.30 , pp. 478-485
    • Smink, B.E.1    Mathijssen, M.P.2    Lusthof, K.J.3
  • 3
    • 42049097456 scopus 로고    scopus 로고
    • Current developments in drug testing in oral fluid
    • Pil K., and Verstraete A. Current developments in drug testing in oral fluid. Ther. Drug Monit. 30 (2008) 196-202
    • (2008) Ther. Drug Monit. , vol.30 , pp. 196-202
    • Pil, K.1    Verstraete, A.2
  • 4
    • 0036010947 scopus 로고    scopus 로고
    • Determination of paramethoxyamphetamine and other amphetamine-related designer drugs by liquid chromatography/sonic spray ionization mass spectrometry
    • Mortier K.A., Dams R., Lambert W.E., et al. Determination of paramethoxyamphetamine and other amphetamine-related designer drugs by liquid chromatography/sonic spray ionization mass spectrometry. Rapid Commun. Mass Spectrom. 16 (2002) 865-870
    • (2002) Rapid Commun. Mass Spectrom. , vol.16 , pp. 865-870
    • Mortier, K.A.1    Dams, R.2    Lambert, W.E.3
  • 5
    • 24144434966 scopus 로고    scopus 로고
    • Screening and confirmatory method for benzodiazepines and hypnotics in oral fluid by LC-MS/MS
    • Kintz P., Villain M., Concheiro M., and Cirimele V. Screening and confirmatory method for benzodiazepines and hypnotics in oral fluid by LC-MS/MS. Forensic Sci Int 150 (2005) 213-220
    • (2005) Forensic Sci Int , vol.150 , pp. 213-220
    • Kintz, P.1    Villain, M.2    Concheiro, M.3    Cirimele, V.4
  • 6
    • 0032884065 scopus 로고    scopus 로고
    • Broad spectrum drug identification directly from urine, using liquid chromatography-tandem mass spectrometry
    • Fitzgerald R.L., Rivera J.D., and Herold D.A. Broad spectrum drug identification directly from urine, using liquid chromatography-tandem mass spectrometry. Clin. Chem. 45 (1999) t-34
    • (1999) Clin. Chem. , vol.45
    • Fitzgerald, R.L.1    Rivera, J.D.2    Herold, D.A.3
  • 7
    • 21844465932 scopus 로고    scopus 로고
    • Replacement of immunoassay by LC tandem mass spectrometry for the routine measurement of drugs of abuse in oral fluid
    • Allen K.R., Azad R., Field H.P., and Blake D.K. Replacement of immunoassay by LC tandem mass spectrometry for the routine measurement of drugs of abuse in oral fluid. Ann. Clin. Biochem. 42 (2005) 277-284
    • (2005) Ann. Clin. Biochem. , vol.42 , pp. 277-284
    • Allen, K.R.1    Azad, R.2    Field, H.P.3    Blake, D.K.4
  • 8
    • 5344275249 scopus 로고    scopus 로고
    • Confirmatory analysis for drugs of abuse in plasma and urine by high-performance liquid chromatography-tandem mass spectrometry with respect to criteria for compound identification
    • Maralikova B., and Weinmann W. Confirmatory analysis for drugs of abuse in plasma and urine by high-performance liquid chromatography-tandem mass spectrometry with respect to criteria for compound identification. J. Chromatogr. B. Analyt. Technol. Biomed. Life Sci. 811 (2004) 21-30
    • (2004) J. Chromatogr. B. Analyt. Technol. Biomed. Life Sci. , vol.811 , pp. 21-30
    • Maralikova, B.1    Weinmann, W.2
  • 9
    • 0029784566 scopus 로고    scopus 로고
    • Simultaneous determination of illicit drugs in human urine by liquid chromatography-mass spectrometry
    • Tatsuno M., Nishikawa M., Katagi M., and Tsuchihashi H. Simultaneous determination of illicit drugs in human urine by liquid chromatography-mass spectrometry. J. Anal. Toxicol. 20 (1996) 281-286
    • (1996) J. Anal. Toxicol. , vol.20 , pp. 281-286
    • Tatsuno, M.1    Nishikawa, M.2    Katagi, M.3    Tsuchihashi, H.4
  • 10
    • 0343006751 scopus 로고    scopus 로고
    • Simultaneous determination of THC-COOH and THC-COOH-glucuronide in urine samples by LC/MS/MS
    • Weinmann W., Vogt S., Goerke R., Muller C., and Bromberger A. Simultaneous determination of THC-COOH and THC-COOH-glucuronide in urine samples by LC/MS/MS. Forensic. Sci. Int. 113 (2000) 381-387
    • (2000) Forensic. Sci. Int. , vol.113 , pp. 381-387
    • Weinmann, W.1    Vogt, S.2    Goerke, R.3    Muller, C.4    Bromberger, A.5
  • 11
    • 0942297956 scopus 로고    scopus 로고
    • Multicomponent screening for drugs of abuse: direct analysis of urine by LC-MS-MS
    • Nordgren H.K., and Beck O. Multicomponent screening for drugs of abuse: direct analysis of urine by LC-MS-MS. Ther. Drug Monit. 26 (2004) 90-97
    • (2004) Ther. Drug Monit. , vol.26 , pp. 90-97
    • Nordgren, H.K.1    Beck, O.2
  • 12
    • 0033824707 scopus 로고    scopus 로고
    • High-throughput quantitative bioanalysis by LC/MS/MS
    • Jemal M. High-throughput quantitative bioanalysis by LC/MS/MS. Biomed. Chromatogr. 14 (2000) 422-429
    • (2000) Biomed. Chromatogr. , vol.14 , pp. 422-429
    • Jemal, M.1
  • 13
    • 51349162644 scopus 로고    scopus 로고
    • Pitfalls and prevention strategies for liquid chromatography-tandem mass spectrometry in the selected reaction-monitoring mode for drug analysis
    • Sauvage F.L., Gaulier J.M., Lachatre G., and Marquet P. Pitfalls and prevention strategies for liquid chromatography-tandem mass spectrometry in the selected reaction-monitoring mode for drug analysis. Clin. Chem. 54 (2008) 1519-1527
    • (2008) Clin. Chem. , vol.54 , pp. 1519-1527
    • Sauvage, F.L.1    Gaulier, J.M.2    Lachatre, G.3    Marquet, P.4
  • 14
    • 14844313671 scopus 로고    scopus 로고
    • Matrix effects: the Achilles heel of quantitative high-performance liquid chromatography-electrospray-tandem mass spectrometry
    • Taylor P.J. Matrix effects: the Achilles heel of quantitative high-performance liquid chromatography-electrospray-tandem mass spectrometry. Clin. Biochem. 38 (2005) 328-334
    • (2005) Clin. Biochem. , vol.38 , pp. 328-334
    • Taylor, P.J.1
  • 15
    • 34547294263 scopus 로고    scopus 로고
    • Current role of liquid chromatography-mass spectrometry in clinical and forensic toxicology
    • Maurer H.H. Current role of liquid chromatography-mass spectrometry in clinical and forensic toxicology. Anal Bioanal. Chem. 388 (2007) 1315-1325
    • (2007) Anal Bioanal. Chem. , vol.388 , pp. 1315-1325
    • Maurer, H.H.1
  • 16
    • 0142195729 scopus 로고    scopus 로고
    • Matrix effect in bio-analysis of illicit drugs with LC-MS/MS: influence of ionization type, sample preparation, and biofluid
    • Dams R., Huestis M.A., Lambert W.E., and Murphy C.M. Matrix effect in bio-analysis of illicit drugs with LC-MS/MS: influence of ionization type, sample preparation, and biofluid. J. Am. Soc. Mass Spectrom. 14 (2003) 1290-1294
    • (2003) J. Am. Soc. Mass Spectrom. , vol.14 , pp. 1290-1294
    • Dams, R.1    Huestis, M.A.2    Lambert, W.E.3    Murphy, C.M.4
  • 17
    • 0346158187 scopus 로고    scopus 로고
    • A study of ion suppression effects in electrospray ionization from mobile phase additives and solid-phase extracts
    • Mallet C.R., Lu Z., and Mazzeo J.R. A study of ion suppression effects in electrospray ionization from mobile phase additives and solid-phase extracts. Rapid Commun. Mass Spectrom. 18 (2004) 49-58
    • (2004) Rapid Commun. Mass Spectrom. , vol.18 , pp. 49-58
    • Mallet, C.R.1    Lu, Z.2    Mazzeo, J.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.