메뉴 건너뛰기




Volumn 20, Issue 10, 2009, Pages 1178-1184

The effect of microrough surface treatment on miniscrews used as orthodontic anchors

Author keywords

Mecha J. K.nical retention; Miniscrews; Orthodontic anchorage; Surface treatment

Indexed keywords

TITANIUM;

EID: 70249083773     PISSN: 09057161     EISSN: 16000501     Source Type: Journal    
DOI: 10.1111/j.1600-0501.2009.01728.x     Document Type: Article
Times cited : (33)

References (40)
  • 8
    • 1342322625 scopus 로고    scopus 로고
    • A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage
    • Cheng, S.J., Tseng, I.Y., Lee, J.J. Kok, S.H. (2004) A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage. International Journal of Oral & Maxillofacial Implants 19 : 100 106.
    • (2004) International Journal of Oral & Maxillofacial Implants , vol.19 , pp. 100-106
    • Cheng, S.J.1    Tseng, I.Y.2    Lee, J.J.3    Kok, S.H.4
  • 9
    • 0032053958 scopus 로고    scopus 로고
    • Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: A histometric study in the canine mandible
    • Cochran, D.L., Schenk, R.K., Lussi, A., Higginbottom, F.L. Buser, D. (1998) Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: a histometric study in the canine mandible. Journal of Biomedical Materials Research 40 : 1 11.
    • (1998) Journal of Biomedical Materials Research , vol.40 , pp. 1-11
    • Cochran, D.L.1    Schenk, R.K.2    Lussi, A.3    Higginbottom, F.L.4    Buser, D.5
  • 10
    • 14544304073 scopus 로고    scopus 로고
    • Temporary anchorage devices in orthodontics: A paradigm shift
    • Cope, J.B. (2005) Temporary anchorage devices in orthodontics: A paradigm shift. Seminars in Orthodontics 11 : 3 9.
    • (2005) Seminars in Orthodontics , vol.11 , pp. 3-9
    • Cope, J.B.1
  • 14
    • 33646501397 scopus 로고    scopus 로고
    • Enhanced bone apposition around biofunctionalized sandblasted and acid-etched titanium implant surfaces. A histomorphometric study in miniature pigs
    • Germanier, Y., Tosatti, S., Broggini, N., Textor, M. Buser, D. (2006) Enhanced bone apposition around biofunctionalized sandblasted and acid-etched titanium implant surfaces. A histomorphometric study in miniature pigs. Clinical Oral Implants Research 17 : 251 257.
    • (2006) Clinical Oral Implants Research , vol.17 , pp. 251-257
    • Germanier, Y.1    Tosatti, S.2    Broggini, N.3    Textor, M.4    Buser, D.5
  • 16
    • 0037210170 scopus 로고    scopus 로고
    • Bone formation after 4 weeks around blood-plasma-modified titanium implants with varying surface topographies: An in vivo study
    • Göransson, A., Jansson, E., Tengvall, P. Wennerberg, A. (2003) Bone formation after 4 weeks around blood-plasma-modified titanium implants with varying surface topographies: an in vivo study. Biomaterials 24 : 197 205.
    • (2003) Biomaterials , vol.24 , pp. 197-205
    • Göransson, A.1    Jansson, E.2    Tengvall, P.3    Wennerberg, A.4
  • 17
    • 0032997613 scopus 로고    scopus 로고
    • The relation between surface roughness and interfacial shear strength for bone-anchored implants. A mathematical model
    • Hansson, S. Norton, M. (1999) The relation between surface roughness and interfacial shear strength for bone-anchored implants. A mathematical model. Journal of Biomechanics 32 : 829 836.
    • (1999) Journal of Biomechanics , vol.32 , pp. 829-836
    • Hansson, S.1    Norton, M.2
  • 18
    • 0025717802 scopus 로고
    • A removal torque and histomorphometric study of commercially pure niobium and titanium implants in rabbit bone
    • Johansson, C.B. Albrektsson, T. (1991) A removal torque and histomorphometric study of commercially pure niobium and titanium implants in rabbit bone. Clinical Oral Implants Research 2 : 24 29.
    • (1991) Clinical Oral Implants Research , vol.2 , pp. 24-29
    • Johansson, C.B.1    Albrektsson, T.2
  • 19
    • 0015597672 scopus 로고
    • Salt Zenker, a stable, nonhemolytic, formaldehyde-free fixative: The addition of salt to other acetic acid fixatives
    • Lillie, R.D., Pizzolato, P. Vacca, L.L. (1973) Salt Zenker, a stable, nonhemolytic, formaldehyde-free fixative: the addition of salt to other acetic acid fixatives. American Journal of Clinical Pathology 59 : 374 375.
    • (1973) American Journal of Clinical Pathology , vol.59 , pp. 374-375
    • Lillie, R.D.1    Pizzolato, P.2    Vacca, L.L.3
  • 20
    • 10844238124 scopus 로고    scopus 로고
    • TOF-SIMS study of bone mineralization on alkali-treated Ti alloy
    • Lu, X., Leng, Y. Weng, L.T. (2004) TOF-SIMS study of bone mineralization on alkali-treated Ti alloy. Journal of Material Science 39 : 6809 6811.
    • (2004) Journal of Material Science , vol.39 , pp. 6809-6811
    • Lu, X.1    Leng, Y.2    Weng, L.T.3
  • 21
    • 33750595177 scopus 로고    scopus 로고
    • Temporary anchorage devices for tooth movement: A review and case reports
    • McGuire, M.K., Scheyer, E.T. Gallerano, R.L. (2006) Temporary anchorage devices for tooth movement: a review and case reports. Journal of Periodeontology 77 : 1613 1624.
    • (2006) Journal of Periodeontology , vol.77 , pp. 1613-1624
    • McGuire, M.K.1    Scheyer, E.T.2    Gallerano, R.L.3
  • 22
    • 1042284432 scopus 로고    scopus 로고
    • Immediate loading of implants used for orthodontic anchorage
    • Melsen, B. Costa, A. (2000) Immediate loading of implants used for orthodontic anchorage. Clinical Orthodontic Research 3 : 23 28.
    • (2000) Clinical Orthodontic Research , vol.3 , pp. 23-28
    • Melsen, B.1    Costa, A.2
  • 23
    • 0035315830 scopus 로고    scopus 로고
    • Biological reactions of alveolar bone to orthodontic loading of oral implants
    • Melsen, B. Lang, N.P. (2001) Biological reactions of alveolar bone to orthodontic loading of oral implants. Clinical Oral Implants Research 12 : 144 152.
    • (2001) Clinical Oral Implants Research , vol.12 , pp. 144-152
    • Melsen, B.1    Lang, N.P.2
  • 25
    • 33746018652 scopus 로고    scopus 로고
    • Implant vs screw loading protocols in orthodontics. A systematic review
    • Ohashia, E., Pechob, O.E., Morona, M. Lagravere, M.O. (2006) Implant vs screw loading protocols in orthodontics. A systematic review. The Angle Orthodontist 76 : 721 727.
    • (2006) The Angle Orthodontist , vol.76 , pp. 721-727
    • Ohashia, E.1    Pechob, O.E.2    Morona, M.3    Lagravere, M.O.4
  • 28
    • 7044264818 scopus 로고    scopus 로고
    • Sliding mechanics with microscrew implant anchorage
    • Park, H.S. Kwon, T.G. (2004) Sliding mechanics with microscrew implant anchorage. The Angle Orthodontist 74 : 703 710.
    • (2004) The Angle Orthodontist , vol.74 , pp. 703-710
    • Park, H.S.1    Kwon, T.G.2
  • 29
    • 18744406031 scopus 로고    scopus 로고
    • Correlation between microtomography and histomorphometry for assessment of implant osseointegration
    • Park, Y.S., Yi, K.Y., Lee, I.S. Jung, Y.C. (2005) Correlation between microtomography and histomorphometry for assessment of implant osseointegration. Clinical Oral Implants Research 16 : 156 160.
    • (2005) Clinical Oral Implants Research , vol.16 , pp. 156-160
    • Park, Y.S.1    Yi, K.Y.2    Lee, I.S.3    Jung, Y.C.4
  • 32
    • 0035256439 scopus 로고    scopus 로고
    • A new microtomographic technique for non-invasive evaluation of the bone structure around implants
    • Sennerby, L., Wennerberg, A. Pasop, F. (2001) A new microtomographic technique for non-invasive evaluation of the bone structure around implants. Clinical Oral Implants Research 12 : 91 94.
    • (2001) Clinical Oral Implants Research , vol.12 , pp. 91-94
    • Sennerby, L.1    Wennerberg, A.2    Pasop, F.3
  • 34
    • 0023471993 scopus 로고
    • The effect of surface macrotexture and hydroxyapatite coating on the mechanical strengths and histologic profiles of titanium implant materials
    • Thomas, K.A., Kay J, F., Cook, S.D. Jarcho, M. (1987) The effect of surface macrotexture and hydroxyapatite coating on the mechanical strengths and histologic profiles of titanium implant materials. Journal of Biomedical Materials Research 21 : 1395 1414.
    • (1987) Journal of Biomedical Materials Research , vol.21 , pp. 1395-1414
    • Thomas, K.A.1    Kay, J.F.2    Cook, S.D.3    Jarcho, M.4
  • 35
    • 0027613203 scopus 로고
    • Endosseous titanium implants during and after orthodontic load - An experimental study in the dog
    • Wehrbein, H. Diedrich, P. (1993) Endosseous titanium implants during and after orthodontic load - an experimental study in the dog. Clinical Oral Implants Research 4 : 76 82.
    • (1993) Clinical Oral Implants Research , vol.4 , pp. 76-82
    • Wehrbein, H.1    Diedrich, P.2
  • 36
    • 0031107903 scopus 로고    scopus 로고
    • Orthodontic anchorage capacity of short titanium screw implants in the maxilla. An experimental study in the dog
    • Wehrbein, H., Glatzmaier, J. Yildirim, M. (1997) Orthodontic anchorage capacity of short titanium screw implants in the maxilla. An experimental study in the dog. Clinical Oral Implants Research 8 : 131 141.
    • (1997) Clinical Oral Implants Research , vol.8 , pp. 131-141
    • Wehrbein, H.1    Glatzmaier, J.2    Yildirim, M.3
  • 38
    • 0029411943 scopus 로고
    • Effect of surface topology on the osseointegration of implant materials in trabecular bone
    • Wong, M., Eulenberger, J., Schenk, R. Hunziker, E. (1995) Effect of surface topology on the osseointegration of implant materials in trabecular bone. Journal of Biomedical Materials Research 29 : 1567 1575.
    • (1995) Journal of Biomedical Materials Research , vol.29 , pp. 1567-1575
    • Wong, M.1    Eulenberger, J.2    Schenk, R.3    Hunziker, E.4
  • 39
    • 33845413000 scopus 로고    scopus 로고
    • Tapered orthodontic miniscrews induce bone - Screw cohesion following immediate loading
    • Yano, S., Motoyoshi, M., Uemura, M., Ono, A. Shimizu, N. (2006) Tapered orthodontic miniscrews induce bone - screw cohesion following immediate loading. European Journal of Orthodontics 28 : 541 546.
    • (2006) European Journal of Orthodontics , vol.28 , pp. 541-546
    • Yano, S.1    Motoyoshi, M.2    Uemura, M.3    Ono, A.4    Shimizu, N.5
  • 40
    • 0345047714 scopus 로고    scopus 로고
    • Osseous healing characteristics of three different implant types. A histologic and histomorphometric study in mini-pigs
    • Zechner, W., Tangl, S., Fürst, G., Tepper, G., Thams, U., Mailath, G. Watzek, G. (2003) Osseous healing characteristics of three different implant types. A histologic and histomorphometric study in mini-pigs. Clinical Oral Implants Research 14 : 150 157.
    • (2003) Clinical Oral Implants Research , vol.14 , pp. 150-157
    • Zechner, W.1    Tangl, S.2    Fürst, G.3    Tepper, G.4    Thams, U.5    Mailath, G.6    Watzek, G.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.