메뉴 건너뛰기




Volumn , Issue , 2009, Pages

A portable potentiostat with molecularly imprinted polymeric electrode for dopamine sensing

Author keywords

Molecularly imprinted polymeric electrode; Portable potentiostat; Potentiostat

Indexed keywords

CALIBRATION CURVES; COMMERCIAL EQUIPMENT; DOPAMINE SENSING; HOMECARE APPLICATIONS; IMPRINTED POLYMERS; LOW COSTS; LOW-NOISE MEASUREMENTS; MOLECULARLY IMPRINTED; MOLECULARLY IMPRINTED POLYMERIC ELECTRODE; PORTABLE POTENTIOSTAT; POTENTIOSTAT; POTENTIOSTATS; SENSING ELEMENTS; SMALL SIZE;

EID: 70149123431     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/CAS-ICTD.2009.4960767     Document Type: Conference Paper
Times cited : (9)

References (11)
  • 5
    • 0041695254 scopus 로고    scopus 로고
    • On the design and characterization of femtoampere current-mode circuits
    • Aug.
    • B. Linares-Barranco and T. Serrano-Gotarredona, "On the design and characterization of femtoampere current-mode circuits," IEEE J. Solid- State Circuits, vol.38, pp. 1353-1363, Aug. 2003.
    • (2003) IEEE J. Solid- State Circuits , vol.38 , pp. 1353-1363
    • Linares-Barranco, B.1    Serrano-Gotarredona, T.2
  • 6
    • 0033704612 scopus 로고    scopus 로고
    • Low-cost electrochemical impedance spectroscopy system for corrosion monitoring of metallic antiquities and works of art
    • Feb.
    • A. Carullo, F. Ferraris, M. Parvis, A. Vallan, E. Angelini, and P. Spinelli, "Low-cost electrochemical impedance spectroscopy system for corrosion monitoring of metallic antiquities and works of art," IEEE Trans. Instrum. and Meas., vol.49, pp.371-375, Feb. 2000.
    • (2000) IEEE Trans. Instrum. and Meas. , vol.49 , pp. 371-375
    • Carullo, A.1    Ferraris, F.2    Parvis, M.3    Vallan, A.4    Angelini, E.5    Spinelli, P.6
  • 7
    • 62649126713 scopus 로고    scopus 로고
    • Measuring system for amperometric chemical sensors using the threeelectrode technique for field application
    • P. R. H. Rodríguez, C. A. G. Vidal, A. M. Pérez, and S. A. Sanromán, "Measuring system for amperometric chemical sensors using the threeelectrode technique for field application," J. Appl. Res. Tech., vol.1, pp. 107-113, 2003.
    • (2003) J. Appl. Res. Tech. , vol.1 , pp. 107-113
    • Rodríguez, P.R.H.1    Vidal, C.A.G.2    Pérez, A.M.3    Sanromán, S.A.4
  • 9
    • 33846644583 scopus 로고    scopus 로고
    • A portable potentiostat for the bilirubin-specific sensor prepared from molecular imprinting
    • Mar.
    • C. Y. Huang, M. J. Syu, C. H. Chang, Y. S. Chang, B. D. Liu, and T. C. Chou, "A portable potentiostat for the bilirubin-specific sensor prepared from molecular imprinting," Biosens. Bioelectron., vol.22, pp. 1694- 1699, Mar. 2007.
    • (2007) Biosens. Bioelectron. , vol.22 , pp. 1694-1699
    • Huang, C.Y.1    Syu, M.J.2    Chang, C.H.3    Chang, Y.S.4    Liu, B.D.5    Chou, T.C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.