메뉴 건너뛰기




Volumn 32, Issue 7, 2009, Pages 549-555

Motion Palpation Used as a Postmanipulation Assessment Tool for Monitoring End-Feel Improvement: A Randomized Controlled Trial of Test Responsiveness

Author keywords

Chiropractic; Manipulation; Palpation, Reliability, and Validity; Research, Evaluation; Spinal

Indexed keywords

PLACEBO;

EID: 70049113277     PISSN: 01614754     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jmpt.2009.08.004     Document Type: Article
Times cited : (15)

References (34)
  • 2
    • 0026787812 scopus 로고
    • The reliability of lumbar motion palpation
    • Panzer D.M. The reliability of lumbar motion palpation. J Manipulative Physiol Ther 15 (1992) 518-524
    • (1992) J Manipulative Physiol Ther , vol.15 , pp. 518-524
    • Panzer, D.M.1
  • 3
    • 70049104127 scopus 로고    scopus 로고
    • Gatterman M. Foundations of chiropractic: subluxation. St. Louis: Mosby year book; 1995. p. 61-2, 150-5.
    • Gatterman M. Foundations of chiropractic: subluxation. St. Louis: Mosby year book; 1995. p. 61-2, 150-5.
  • 6
    • 70049115664 scopus 로고    scopus 로고
    • Bergmann TF, Peterson, Lawrence DJ. Chiropractic technique: principles and procedures. New York: Churchill Livingstone, Inc. 1993: 87-97, 125, 133.
    • Bergmann TF, Peterson, Lawrence DJ. Chiropractic technique: principles and procedures. New York: Churchill Livingstone, Inc. 1993: 87-97, 125, 133.
  • 9
    • 0029593560 scopus 로고
    • Short-term responsiveness of manual thoracic end-play assessment to spinal manipulation: a randomized controlled trial of construct validity
    • Haas M., Panzer D., Peterson D., and Raphael R. Short-term responsiveness of manual thoracic end-play assessment to spinal manipulation: a randomized controlled trial of construct validity. J Manipulative Physiol Ther 18 (1995) 582-588
    • (1995) J Manipulative Physiol Ther , vol.18 , pp. 582-588
    • Haas, M.1    Panzer, D.2    Peterson, D.3    Raphael, R.4
  • 10
    • 0004580108 scopus 로고
    • Motion Palpation Institute, Huntington Beach
    • Faye L.J. Motion palpation of the spine (1981), Motion Palpation Institute, Huntington Beach 27-29
    • (1981) Motion palpation of the spine , pp. 27-29
    • Faye, L.J.1
  • 13
    • 0000210396 scopus 로고
    • Reliability of manual end-play palpation of the thoracic spine
    • Haas M., Raphael R., Panzer D., and Peterson D. Reliability of manual end-play palpation of the thoracic spine. Chiropr Tech 7 (1995) 120-124
    • (1995) Chiropr Tech , vol.7 , pp. 120-124
    • Haas, M.1    Raphael, R.2    Panzer, D.3    Peterson, D.4
  • 14
    • 0022036963 scopus 로고
    • Reliability study of detection of somatic dysfunctions in the cervical spine
    • DeBoer K., Harmon R., Tuttle C.D., and Wallace H. Reliability study of detection of somatic dysfunctions in the cervical spine. J Manipulative Physiol Ther 8 (1985) 9-16
    • (1985) J Manipulative Physiol Ther , vol.8 , pp. 9-16
    • DeBoer, K.1    Harmon, R.2    Tuttle, C.D.3    Wallace, H.4
  • 15
    • 0023390541 scopus 로고
    • Inter- and intra-examiner reliability of palpation for sacroiliac joint dysfunction
    • Carmichael J.P. Inter- and intra-examiner reliability of palpation for sacroiliac joint dysfunction. J Manipulative Physiol Ther 10 (1987) 164-171
    • (1987) J Manipulative Physiol Ther , vol.10 , pp. 164-171
    • Carmichael, J.P.1
  • 16
    • 0024828052 scopus 로고
    • Interexaminer concordance in detecting joint-play asymmetries in the cervical spines of otherwise asymptomatic subjects
    • Nansel D.D., Peneff A.L., Jansen R.D., and Cooperstein R. Interexaminer concordance in detecting joint-play asymmetries in the cervical spines of otherwise asymptomatic subjects. J Manipulative Physiol Ther 12 (1989) 428-433
    • (1989) J Manipulative Physiol Ther , vol.12 , pp. 428-433
    • Nansel, D.D.1    Peneff, A.L.2    Jansen, R.D.3    Cooperstein, R.4
  • 17
    • 0001057006 scopus 로고
    • Intra and interexaminer reliability of motion palpation in the cervical spine
    • Mior S.A., and King R. Intra and interexaminer reliability of motion palpation in the cervical spine. J Can Chiropr Assoc 29 (1985) 195-199
    • (1985) J Can Chiropr Assoc , vol.29 , pp. 195-199
    • Mior, S.A.1    King, R.2
  • 18
    • 27544509026 scopus 로고    scopus 로고
    • Inter-examiner reliability of passive assessment of intervertebral motion in the cervical and lumbar spine: a systematic review
    • Van Trijffel E., Anderegg Q., Bossuyt P.M.M., and Lucas C. Inter-examiner reliability of passive assessment of intervertebral motion in the cervical and lumbar spine: a systematic review. Man Ther 10 (2005) 256-269
    • (2005) Man Ther , vol.10 , pp. 256-269
    • Van Trijffel, E.1    Anderegg, Q.2    Bossuyt, P.M.M.3    Lucas, C.4
  • 19
    • 54549086637 scopus 로고    scopus 로고
    • Spinal motion palpation: a comparison of studies that assessed intersegmental end feel vs excursion
    • Haneline M.T., Cooperstain R., Young M., and Birkeland K. Spinal motion palpation: a comparison of studies that assessed intersegmental end feel vs excursion. J Manipulative Physiol Ther 31 (2008) 616-626
    • (2008) J Manipulative Physiol Ther , vol.31 , pp. 616-626
    • Haneline, M.T.1    Cooperstain, R.2    Young, M.3    Birkeland, K.4
  • 20
    • 33747028753 scopus 로고    scopus 로고
    • Manual examination of the spine. A systematic, critical literature review of reproducibility
    • Stochkendahl M.J., Christensen H.W., Hartvigsen J., et al. Manual examination of the spine. A systematic, critical literature review of reproducibility. J Manipulative Physiol Ther 29 (2006) 475-485
    • (2006) J Manipulative Physiol Ther , vol.29 , pp. 475-485
    • Stochkendahl, M.J.1    Christensen, H.W.2    Hartvigsen, J.3
  • 21
    • 14744281817 scopus 로고    scopus 로고
    • On the subject of human subjects
    • Johnson C. On the subject of human subjects. J Manipulative Physiol Ther 28 (2005) 79-80
    • (2005) J Manipulative Physiol Ther , vol.28 , pp. 79-80
    • Johnson, C.1
  • 24
    • 70049086549 scopus 로고
    • The spine: anatomy, biomechanics, assessment, and adjustive techniques
    • Bergmann T.F., Peterson D.H., and Lawrence D.J. (Eds), Churchill Livingston, Inc., New York, USA
    • Peterson D.H., and Bergmann T.F. The spine: anatomy, biomechanics, assessment, and adjustive techniques. In: Bergmann T.F., Peterson D.H., and Lawrence D.J. (Eds). Chiropractic technique: principles and procedures (1993), Churchill Livingston, Inc., New York, USA 241-293
    • (1993) Chiropractic technique: principles and procedures , pp. 241-293
    • Peterson, D.H.1    Bergmann, T.F.2
  • 26
    • 0011705967 scopus 로고
    • Application of health status measures
    • Jenkinson C. (Ed), University College London Press, London, UK
    • Fitzpatrick R. Application of health status measures. In: Jenkinson C. (Ed). Measuring health and medical outcomes (1994), University College London Press, London, UK 36-37
    • (1994) Measuring health and medical outcomes , pp. 36-37
    • Fitzpatrick, R.1
  • 27
    • 0016288477 scopus 로고
    • Proportion of disease caused or prevented by a given exposure, trait or intervention
    • Miettinen O.S. Proportion of disease caused or prevented by a given exposure, trait or intervention. Am J Epidemiol 99 (1974) 325-332
    • (1974) Am J Epidemiol , vol.99 , pp. 325-332
    • Miettinen, O.S.1
  • 30
    • 0025882540 scopus 로고
    • The reliability of reliability
    • Haas M. The reliability of reliability. J Manipulative Physiol Ther 14 (1991) 199-208
    • (1991) J Manipulative Physiol Ther , vol.14 , pp. 199-208
    • Haas, M.1
  • 31
  • 33
    • 3042776741 scopus 로고    scopus 로고
    • Determining cavitation location during lumbar and thoracic spinal manipulation: is spinal manipulation accurate and specific?
    • Ross J.K., Bereznick D.E., and McGill S.M. Determining cavitation location during lumbar and thoracic spinal manipulation: is spinal manipulation accurate and specific?. Spine 29 (2004) 1452-1457
    • (2004) Spine , vol.29 , pp. 1452-1457
    • Ross, J.K.1    Bereznick, D.E.2    McGill, S.M.3
  • 34
    • 0037480035 scopus 로고    scopus 로고
    • The audible pop is not necessary for successful spinal high-velocity thrust manipulation in individuals with low back pain
    • Flynn T.W., Fritz J.M., Wainner R.S., and Whitman J.M. The audible pop is not necessary for successful spinal high-velocity thrust manipulation in individuals with low back pain. Arch Phys Med Rehabil 84 (2003) 1057-1060
    • (2003) Arch Phys Med Rehabil , vol.84 , pp. 1057-1060
    • Flynn, T.W.1    Fritz, J.M.2    Wainner, R.S.3    Whitman, J.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.