-
1
-
-
0006444139
-
Importance of porosity in arterial prostheses
-
W. J. Fry, M. S. Deweese, R. O. Kraft, and C. B. Ernst, "Importance of porosity in arterial prostheses," Arch. Surgery, 88, 836-842 (1964).
-
(1964)
Arch. Surgery
, vol.88
, pp. 836-842
-
-
Fry, W.J.1
Deweese, M.S.2
Kraft, R.O.3
Ernst, C.B.4
-
2
-
-
0026192486
-
In vivo evaluation of porous versus skinned polyurethane-polydimethylsiloxane small diameter vascular grafts
-
T. Okoshi, M. Goddard, P. M. Galletti, and G. Soldani, "In vivo evaluation of porous versus skinned polyurethane-polydimethylsiloxane small diameter vascular grafts," Trans. Am. Soc. Artif. Intern. Organs, 37, M480-M482 (1991).
-
(1991)
Trans. Am. Soc. Artif. Intern. Organs
, vol.37
-
-
Okoshi, T.1
Goddard, M.2
Galletti, P.M.3
Soldani, G.4
-
3
-
-
0022529154
-
Mechanisms of arterial graft healing: Rapid transmural capillary ingrowth provides a source of intimai endothelium and smooth muscle in porous PTFE prostheses
-
A. W. Clowes, T. R. Kirkman, and M. A. Reidy, "Mechanisms of arterial graft healing: Rapid transmural capillary ingrowth provides a source of intimai endothelium and smooth muscle in porous PTFE prostheses," Am. J. Pathol., 123, 220-130 (1986).
-
(1986)
Am. J. Pathol.
, vol.123
, pp. 220-1130
-
-
Clowes, A.W.1
Kirkman, T.R.2
Reidy, M.A.3
-
4
-
-
0017124467
-
Pulsatile blood-flow in arterial grafts
-
R. N. Baird and W. M. Abbott, "Pulsatile blood-flow in arterial grafts," Lancet, 30, 948-949 (1976).
-
(1976)
Lancet
, vol.30
, pp. 948-949
-
-
Baird, R.N.1
Abbott, W.M.2
-
5
-
-
0023156064
-
Effect of compliance mismatch on vascular graft patency
-
W. M. Abbott, J. Mergerman, J. E. Hasson, G. L'Italien, and D. F. Warnock, "Effect of compliance mismatch on vascular graft patency," J. Vasc. Surg. 5, 376-382 (1987).
-
(1987)
J. Vasc. Surg.
, vol.5
, pp. 376-382
-
-
Abbott, W.M.1
Mergerman, J.2
Hasson, J.E.3
L'Italien, G.4
Warnock, D.F.5
-
6
-
-
0019306348
-
Compliance: A continuing problem with vascular grafts
-
C. E. Kinley and A. E. Marble, "Compliance: A continuing problem with vascular grafts," J. Cardiovasc. Surg., 21, 163-170 (1980).
-
(1980)
J. Cardiovasc. Surg.
, vol.21
, pp. 163-170
-
-
Kinley, C.E.1
Marble, A.E.2
-
7
-
-
0026832789
-
Effects of a vascular graft/natural artery compliance mismatch on pulsatile flow
-
S. F. C. Stewart and D. J. Lyman, "Effects of a vascular graft/natural artery compliance mismatch on pulsatile flow," J. Biomech., 25, 297-310 (1992).
-
(1992)
J. Biomech.
, vol.25
, pp. 297-310
-
-
Stewart, S.F.C.1
Lyman, D.J.2
-
8
-
-
0022003831
-
Mechanisms of arterial graft gailure: 1. Role of cellular proliferation in early healing of PTFE prostheses
-
A. W. Clowes, A. W. Gown, S. R. Hanson, and M. A. Reidy, "Mechanisms of arterial graft gailure: 1. Role of cellular proliferation in early healing of PTFE prostheses," Am. J. Pathol., 118, 43-54 (1985).
-
(1985)
Am. J. Pathol.
, vol.118
, pp. 43-54
-
-
Clowes, A.W.1
Gown, A.W.2
Hanson, S.R.3
Reidy, M.A.4
-
9
-
-
0015970531
-
Stress at vascular anastomosis in relation to host artery: Synthetic graft diameter
-
C. E. Kinley, P. E. Paasche, A. S. MacDonald, and A. E. Marble, "Stress at vascular anastomosis in relation to host artery: Synthetic graft diameter," Surgery, 75, 28-30 (1974).
-
(1974)
Surgery
, vol.75
, pp. 28-30
-
-
Kinley, C.E.1
Paasche, P.E.2
MacDonald, A.S.3
Marble, A.E.4
-
10
-
-
0027263096
-
Shear stress modulates the proliferation rate, protein syntheses, and mitogenic activity of arterial smooth muscle cells
-
A. V. Sterpetti, A. Cavallaro, L. S. D' Angelo, B. Cardillo, and A. Cavallaro, "Shear stress modulates the proliferation rate, protein syntheses, and mitogenic activity of arterial smooth muscle cells," Surgery, 113, 691-699 (1993).
-
(1993)
Surgery
, vol.113
, pp. 691-699
-
-
Sterpetti, A.V.1
Cavallaro, A.2
D' Angelo, L.S.3
Cardillo, B.4
Cavallaro, A.5
-
11
-
-
0023683967
-
Response of porcine aortic smooth cells to cyclic tensional deformation in culture
-
B. E. Sumpio and A. J. Banes, "Response of porcine aortic smooth cells to cyclic tensional deformation in culture," J. Surg- Res., 44, 696-701 (1988).
-
(1988)
J. Surg- Res.
, vol.44
, pp. 696-701
-
-
Sumpio, B.E.1
Banes, A.J.2
-
12
-
-
0021063201
-
A fibrous polyurethane microvascular prosthesis
-
F. Hess, C. Jerusalem, and B. Braun, "A fibrous polyurethane microvascular prosthesis," J. Cardiovasc, Surg., 24, 509-515 (1983).
-
(1983)
J. Cardiovasc, Surg.
, vol.24
, pp. 509-515
-
-
Hess, F.1
Jerusalem, C.2
Braun, B.3
-
13
-
-
0021645526
-
"Small vessel replacement with elastomeric protein composite materials: Preliminary studies
-
H. Kambic, S. Murabayashi, R. Yozu, T. Morimoto, M. Furuse, et al., "Small vessel replacement with elastomeric protein composite materials: Preliminary studies," Trans. Am. Soc. Artif. Intern. Organs, 30, 406-410 (1984).
-
(1984)
Trans. Am. Soc. Artif. Intern. Organs
, vol.30
, pp. 406-410
-
-
Kambic, H.1
Murabayashi, S.2
Yozu, R.3
Morimoto, T.4
Furuse, M.5
-
14
-
-
0024737482
-
Ultraviolet laser ablation of organic polymers
-
R. Srinivasan and B. Braren, "Ultraviolet laser ablation of organic polymers," Chem. Rev., 89, 1303-1316 (1989).
-
(1989)
Chem. Rev.
, vol.89
, pp. 1303-1316
-
-
Srinivasan, R.1
Braren, B.2
-
15
-
-
0029380425
-
Surface microarchitectural design in biomedical applications: Preparation of microporous polymer surfaces by an excimer laser ablation technique
-
Y. Nakayama and T. Matsuda, "Surface microarchitectural design in biomedical applications: Preparation of microporous polymer surfaces by an excimer laser ablation technique," J. Biomed. Mater. Res., 29, 1295-1301 (1995).
-
(1995)
J. Biomed. Mater. Res.
, vol.29
, pp. 1295-1301
-
-
Nakayama, Y.1
Matsuda, T.2
-
16
-
-
0028932903
-
Benzophenone-derivatized gelatin as photocurable hemostatic glue: Gelation characteristics by an excimer laser irradiation and its in vivo performance
-
Y. Nakayama, K. Ishibashi, and T. Matsuda, "Benzophenone-derivatized gelatin as photocurable hemostatic glue: Gelation characteristics by an excimer laser irradiation and its in vivo performance," Jpn. J. Artif. Organs, 24, 102-105 (1995).
-
(1995)
Jpn. J. Artif. Organs
, vol.24
, pp. 102-105
-
-
Nakayama, Y.1
Ishibashi, K.2
Matsuda, T.3
-
17
-
-
0023157588
-
Strain energy density function and uniform strain hypothesis for arterial mechanics
-
K. Takamizawa and K. Hayashi, "Strain energy density function and uniform strain hypothesis for arterial mechanics," J. Biomech., 20, 7-17 (1987).
-
(1987)
J. Biomech.
, vol.20
, pp. 7-17
-
-
Takamizawa, K.1
Hayashi, K.2
-
18
-
-
0018898430
-
Stiffness and elastic behavior of human intracranial and extracranial arteries
-
K. Hayashi, H. Handa, S. Nagasawa, et al: "Stiffness and elastic behavior of human intracranial and extracranial arteries," J. Biomech., 13, 175-184 (1980).
-
(1980)
J. Biomech.
, vol.13
, pp. 175-184
-
-
Hayashi, K.1
Handa, H.2
Nagasawa, S.3
-
19
-
-
0000956276
-
Long-term behavior of a Dacron arterial substitute
-
D. E. Szilagyi, R. F. Smith, J. P. Ellioyy, and H. M. Allen, "Long-term behavior of a Dacron arterial substitute," Ann. Surg., 162, 453-477 (1965).
-
(1965)
Ann. Surg.
, vol.162
, pp. 453-477
-
-
Szilagyi, D.E.1
Smith, R.F.2
Ellioyy, J.P.3
Allen, H.M.4
-
20
-
-
0023709214
-
A clinical survey of aortobifemoral bypass using two inherently different graft types
-
I. Cintora, D. E. Pearce, and J. A. Cannon, "A clinical survey of aortobifemoral bypass using two inherently different graft types," Ann. Surg., 208, 625-630 (1988).
-
(1988)
Ann. Surg.
, vol.208
, pp. 625-630
-
-
Cintora, I.1
Pearce, D.E.2
Cannon, J.A.3
-
21
-
-
0022344715
-
Saphenous vein or PTFE for femoropopliteal bypass: A prospective randomized trial
-
H. W. Tilanus, H. Obertop, and H. Van Urk, "Saphenous vein or PTFE for femoropopliteal bypass: A prospective randomized trial," Ann. Surg., 202, 780-782 (1985).
-
(1985)
Ann. Surg.
, vol.202
, pp. 780-782
-
-
Tilanus, H.W.1
Obertop, H.2
Van Urk, H.3
-
23
-
-
0006410113
-
Mechanical properties and hemodynamics in coronary arteries
-
K. Kitamura, H. Abe, and K. Sagawa (eds.), Japan Scientific Societies Press, Tokyo
-
K. Hayashi, Y. Igarashi, and K. Takamizawa, "Mechanical properties and hemodynamics in coronary arteries," in New Approaches in Cardiac Mechanics, K. Kitamura, H. Abe, and K. Sagawa (eds.), Japan Scientific Societies Press, Tokyo, 1986, pp. 285-294.
-
(1986)
In New Approaches in Cardiac Mechanics
, pp. 285-294
-
-
Hayashi, K.1
Igarashi, Y.2
Takamizawa, K.3
-
24
-
-
0030176014
-
Surface microarchitectural design in biomedical applications: In vitro transmural endothelialization on microporous segmented polyurethane filmes using an excimer laser
-
to appear
-
T. Matsuda and Y. Nakayama, "Surface microarchitectural design in biomedical applications: In vitro transmural endothelialization on microporous segmented polyurethane filmes using an excimer laser," J. Biomed. Mater. Res., to appear.
-
J. Biomed. Mater. Res.
-
-
Matsuda, T.1
Nakayama, Y.2
|