메뉴 건너뛰기




Volumn 31, Issue 1, 1996, Pages 27-33

Novel compliant and tissue-permeable microporous polyurethane vascular prosthesis fabricated using an excimer laser ablation technique

Author keywords

[No Author keywords available]

Indexed keywords

COATED MATERIALS; COMPUTER APPLICATIONS; EXCIMER LASERS; HYDROGELS; LASER ABLATION; MECHANICAL PERMEABILITY; PHOTOCHEMICAL REACTIONS; POLYURETHANES; POROUS MATERIALS; SCANNING ELECTRON MICROSCOPY; STIFFNESS; TISSUE;

EID: 0030152429     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1097-4636(199605)31:1<27::AID-JBM4>3.0.CO;2-S     Document Type: Article
Times cited : (69)

References (24)
  • 1
  • 2
    • 0026192486 scopus 로고
    • In vivo evaluation of porous versus skinned polyurethane-polydimethylsiloxane small diameter vascular grafts
    • T. Okoshi, M. Goddard, P. M. Galletti, and G. Soldani, "In vivo evaluation of porous versus skinned polyurethane-polydimethylsiloxane small diameter vascular grafts," Trans. Am. Soc. Artif. Intern. Organs, 37, M480-M482 (1991).
    • (1991) Trans. Am. Soc. Artif. Intern. Organs , vol.37
    • Okoshi, T.1    Goddard, M.2    Galletti, P.M.3    Soldani, G.4
  • 3
    • 0022529154 scopus 로고
    • Mechanisms of arterial graft healing: Rapid transmural capillary ingrowth provides a source of intimai endothelium and smooth muscle in porous PTFE prostheses
    • A. W. Clowes, T. R. Kirkman, and M. A. Reidy, "Mechanisms of arterial graft healing: Rapid transmural capillary ingrowth provides a source of intimai endothelium and smooth muscle in porous PTFE prostheses," Am. J. Pathol., 123, 220-130 (1986).
    • (1986) Am. J. Pathol. , vol.123 , pp. 220-1130
    • Clowes, A.W.1    Kirkman, T.R.2    Reidy, M.A.3
  • 4
    • 0017124467 scopus 로고
    • Pulsatile blood-flow in arterial grafts
    • R. N. Baird and W. M. Abbott, "Pulsatile blood-flow in arterial grafts," Lancet, 30, 948-949 (1976).
    • (1976) Lancet , vol.30 , pp. 948-949
    • Baird, R.N.1    Abbott, W.M.2
  • 6
    • 0019306348 scopus 로고
    • Compliance: A continuing problem with vascular grafts
    • C. E. Kinley and A. E. Marble, "Compliance: A continuing problem with vascular grafts," J. Cardiovasc. Surg., 21, 163-170 (1980).
    • (1980) J. Cardiovasc. Surg. , vol.21 , pp. 163-170
    • Kinley, C.E.1    Marble, A.E.2
  • 7
    • 0026832789 scopus 로고
    • Effects of a vascular graft/natural artery compliance mismatch on pulsatile flow
    • S. F. C. Stewart and D. J. Lyman, "Effects of a vascular graft/natural artery compliance mismatch on pulsatile flow," J. Biomech., 25, 297-310 (1992).
    • (1992) J. Biomech. , vol.25 , pp. 297-310
    • Stewart, S.F.C.1    Lyman, D.J.2
  • 8
    • 0022003831 scopus 로고
    • Mechanisms of arterial graft gailure: 1. Role of cellular proliferation in early healing of PTFE prostheses
    • A. W. Clowes, A. W. Gown, S. R. Hanson, and M. A. Reidy, "Mechanisms of arterial graft gailure: 1. Role of cellular proliferation in early healing of PTFE prostheses," Am. J. Pathol., 118, 43-54 (1985).
    • (1985) Am. J. Pathol. , vol.118 , pp. 43-54
    • Clowes, A.W.1    Gown, A.W.2    Hanson, S.R.3    Reidy, M.A.4
  • 9
    • 0015970531 scopus 로고
    • Stress at vascular anastomosis in relation to host artery: Synthetic graft diameter
    • C. E. Kinley, P. E. Paasche, A. S. MacDonald, and A. E. Marble, "Stress at vascular anastomosis in relation to host artery: Synthetic graft diameter," Surgery, 75, 28-30 (1974).
    • (1974) Surgery , vol.75 , pp. 28-30
    • Kinley, C.E.1    Paasche, P.E.2    MacDonald, A.S.3    Marble, A.E.4
  • 10
    • 0027263096 scopus 로고
    • Shear stress modulates the proliferation rate, protein syntheses, and mitogenic activity of arterial smooth muscle cells
    • A. V. Sterpetti, A. Cavallaro, L. S. D' Angelo, B. Cardillo, and A. Cavallaro, "Shear stress modulates the proliferation rate, protein syntheses, and mitogenic activity of arterial smooth muscle cells," Surgery, 113, 691-699 (1993).
    • (1993) Surgery , vol.113 , pp. 691-699
    • Sterpetti, A.V.1    Cavallaro, A.2    D' Angelo, L.S.3    Cardillo, B.4    Cavallaro, A.5
  • 11
    • 0023683967 scopus 로고
    • Response of porcine aortic smooth cells to cyclic tensional deformation in culture
    • B. E. Sumpio and A. J. Banes, "Response of porcine aortic smooth cells to cyclic tensional deformation in culture," J. Surg- Res., 44, 696-701 (1988).
    • (1988) J. Surg- Res. , vol.44 , pp. 696-701
    • Sumpio, B.E.1    Banes, A.J.2
  • 12
    • 0021063201 scopus 로고
    • A fibrous polyurethane microvascular prosthesis
    • F. Hess, C. Jerusalem, and B. Braun, "A fibrous polyurethane microvascular prosthesis," J. Cardiovasc, Surg., 24, 509-515 (1983).
    • (1983) J. Cardiovasc, Surg. , vol.24 , pp. 509-515
    • Hess, F.1    Jerusalem, C.2    Braun, B.3
  • 14
    • 0024737482 scopus 로고
    • Ultraviolet laser ablation of organic polymers
    • R. Srinivasan and B. Braren, "Ultraviolet laser ablation of organic polymers," Chem. Rev., 89, 1303-1316 (1989).
    • (1989) Chem. Rev. , vol.89 , pp. 1303-1316
    • Srinivasan, R.1    Braren, B.2
  • 15
    • 0029380425 scopus 로고
    • Surface microarchitectural design in biomedical applications: Preparation of microporous polymer surfaces by an excimer laser ablation technique
    • Y. Nakayama and T. Matsuda, "Surface microarchitectural design in biomedical applications: Preparation of microporous polymer surfaces by an excimer laser ablation technique," J. Biomed. Mater. Res., 29, 1295-1301 (1995).
    • (1995) J. Biomed. Mater. Res. , vol.29 , pp. 1295-1301
    • Nakayama, Y.1    Matsuda, T.2
  • 16
    • 0028932903 scopus 로고
    • Benzophenone-derivatized gelatin as photocurable hemostatic glue: Gelation characteristics by an excimer laser irradiation and its in vivo performance
    • Y. Nakayama, K. Ishibashi, and T. Matsuda, "Benzophenone-derivatized gelatin as photocurable hemostatic glue: Gelation characteristics by an excimer laser irradiation and its in vivo performance," Jpn. J. Artif. Organs, 24, 102-105 (1995).
    • (1995) Jpn. J. Artif. Organs , vol.24 , pp. 102-105
    • Nakayama, Y.1    Ishibashi, K.2    Matsuda, T.3
  • 17
    • 0023157588 scopus 로고
    • Strain energy density function and uniform strain hypothesis for arterial mechanics
    • K. Takamizawa and K. Hayashi, "Strain energy density function and uniform strain hypothesis for arterial mechanics," J. Biomech., 20, 7-17 (1987).
    • (1987) J. Biomech. , vol.20 , pp. 7-17
    • Takamizawa, K.1    Hayashi, K.2
  • 18
    • 0018898430 scopus 로고
    • Stiffness and elastic behavior of human intracranial and extracranial arteries
    • K. Hayashi, H. Handa, S. Nagasawa, et al: "Stiffness and elastic behavior of human intracranial and extracranial arteries," J. Biomech., 13, 175-184 (1980).
    • (1980) J. Biomech. , vol.13 , pp. 175-184
    • Hayashi, K.1    Handa, H.2    Nagasawa, S.3
  • 19
    • 0000956276 scopus 로고
    • Long-term behavior of a Dacron arterial substitute
    • D. E. Szilagyi, R. F. Smith, J. P. Ellioyy, and H. M. Allen, "Long-term behavior of a Dacron arterial substitute," Ann. Surg., 162, 453-477 (1965).
    • (1965) Ann. Surg. , vol.162 , pp. 453-477
    • Szilagyi, D.E.1    Smith, R.F.2    Ellioyy, J.P.3    Allen, H.M.4
  • 20
    • 0023709214 scopus 로고
    • A clinical survey of aortobifemoral bypass using two inherently different graft types
    • I. Cintora, D. E. Pearce, and J. A. Cannon, "A clinical survey of aortobifemoral bypass using two inherently different graft types," Ann. Surg., 208, 625-630 (1988).
    • (1988) Ann. Surg. , vol.208 , pp. 625-630
    • Cintora, I.1    Pearce, D.E.2    Cannon, J.A.3
  • 21
    • 0022344715 scopus 로고
    • Saphenous vein or PTFE for femoropopliteal bypass: A prospective randomized trial
    • H. W. Tilanus, H. Obertop, and H. Van Urk, "Saphenous vein or PTFE for femoropopliteal bypass: A prospective randomized trial," Ann. Surg., 202, 780-782 (1985).
    • (1985) Ann. Surg. , vol.202 , pp. 780-782
    • Tilanus, H.W.1    Obertop, H.2    Van Urk, H.3
  • 23
    • 0006410113 scopus 로고
    • Mechanical properties and hemodynamics in coronary arteries
    • K. Kitamura, H. Abe, and K. Sagawa (eds.), Japan Scientific Societies Press, Tokyo
    • K. Hayashi, Y. Igarashi, and K. Takamizawa, "Mechanical properties and hemodynamics in coronary arteries," in New Approaches in Cardiac Mechanics, K. Kitamura, H. Abe, and K. Sagawa (eds.), Japan Scientific Societies Press, Tokyo, 1986, pp. 285-294.
    • (1986) In New Approaches in Cardiac Mechanics , pp. 285-294
    • Hayashi, K.1    Igarashi, Y.2    Takamizawa, K.3
  • 24
    • 0030176014 scopus 로고    scopus 로고
    • Surface microarchitectural design in biomedical applications: In vitro transmural endothelialization on microporous segmented polyurethane filmes using an excimer laser
    • to appear
    • T. Matsuda and Y. Nakayama, "Surface microarchitectural design in biomedical applications: In vitro transmural endothelialization on microporous segmented polyurethane filmes using an excimer laser," J. Biomed. Mater. Res., to appear.
    • J. Biomed. Mater. Res.
    • Matsuda, T.1    Nakayama, Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.