-
1
-
-
0035084339
-
Spirometric pulmonary function in healthy preschool children
-
Eigen H, Bieler H, Grant D, Christoph K, Terrill D, Heilman DK, Ambrosius WT, Tepper RS. Spirometric pulmonary function in healthy preschool children. Am J Respir Crit Care Med 2001;163:619-623. (Pubitemid 32230819)
-
(2001)
American Journal of Respiratory and Critical Care Medicine
, vol.163
, Issue.3 I
, pp. 619-623
-
-
Eigen, H.1
Bieler, H.2
Grant, D.3
Christoph, K.4
Terrill, D.5
Heilman, D.K.6
Ambrosius, W.T.7
Tepper, R.S.8
-
2
-
-
2442430704
-
Quality control for spirometry in preschool children with and without lung disease
-
Aurora P, Stocks J, Oliver C, Saunders C, Castle R, Chaziparasidis G, Bush A. Quality control for spirometry in preschool children with and without lung disease. Am J Respir Crit Care Med 2004;169:1152-1159. (Pubitemid 38624796)
-
(2004)
American Journal of Respiratory and Critical Care Medicine
, vol.169
, Issue.10
, pp. 1152-1159
-
-
Aurora, P.1
Stocks, J.2
Oliver, C.3
Saunders, C.4
Castle, R.5
Chaziparasidis, G.6
Bush, A.7
-
3
-
-
34250190592
-
An Official American Thoracic Society/European Respiratory Society Statement: Pulmonary function testing in preschool children
-
DOI 10.1164/rccm.200605-642ST
-
Beydon N, Davis SD, Lombardi E, Allen JL, Arets HG, Aurora P, Bisgaard H, Davis GM, Ducharme FM, Eigen H, et al. An official American Thoracic Society/European Respiratory Society statement: pulmonary function testing in preschool children. Am J Respir Crit Care Med 2007;175:1304-1345. (Pubitemid 46905757)
-
(2007)
American Journal of Respiratory and Critical Care Medicine
, vol.175
, Issue.12
, pp. 1304-1345
-
-
Beydon, N.1
Davis, S.D.2
Lombardi, E.3
Allen, J.L.4
Arets, H.G.M.5
Aurora, P.6
Bisgaard, H.7
Davis, G.M.8
Ducharme, F.M.9
Eigen, H.10
Gappa, M.11
Gaultier, C.12
Gustafsson, P.M.13
Hall, G.L.14
Hantos, Z.15
Healy, M.J.R.16
Jones, M.H.17
Klug, B.18
Carlsen, K.C.L.19
McKenzie, S.A.20
Marchal, F.21
Mayer, O.H.22
Merkus, P.J.F.M.23
Morris, M.G.24
Oostveen, E.25
Pillow, J.J.26
Seddon, P.C.27
Silverman, M.28
Sly, P.D.29
Stocks, J.30
Tepper, R.S.31
Vilozni, D.32
Wilson, N.M.33
more..
-
4
-
-
35148897621
-
Reference equations for pulmonary function tests in preschool children: A review
-
DOI 10.1002/ppul.20691
-
Stanojevic S, Wade A, Lum S, Stocks J. Reference equations for pulmonary function tests in preschool children: a review. Pediatr Pulmonol 2007;42:962-972. (Pubitemid 47549804)
-
(2007)
Pediatric Pulmonology
, vol.42
, Issue.10
, pp. 962-972
-
-
Stanojevic, S.1
Wade, A.2
Lum, S.3
Stocks, J.4
-
6
-
-
38849129311
-
Reference ranges for spirometry across all ages: A new approach
-
DOI 10.1164/rccm.200708-1248OC
-
Stanojevic S, Wade A, Stocks J, Hankinson J, Coates AL, Pan H, Rosenthal M, Corey M, Lebecque P, Cole TJ. Reference ranges for spirometry across all ages: a new approach. Am J Respir Crit Care Med 2008;177:253-260. (Pubitemid 351198367)
-
(2008)
American Journal of Respiratory and Critical Care Medicine
, vol.177
, Issue.3
, pp. 253-260
-
-
Stanojevic, S.1
Wade, A.2
Stocks, J.3
Hankinson, J.4
Coates, A.L.5
Pan, H.6
Rosenthal, M.7
Corey, M.8
Lebecque, P.9
Cole, T.J.10
-
7
-
-
64549152063
-
Age- And size-related reference ranges: A case study of spirometry through childhood and adulthood
-
Cole TJ, Stanojevic S, Stocks J, Coates AL, Hankinson JL, Wade AM. Age- and size-related reference ranges: a case study of spirometry through childhood and adulthood. Stat Med 2009;28:880-898.
-
(2009)
Stat Med
, vol.28
, pp. 880-898
-
-
Cole, T.J.1
Stanojevic, S.2
Stocks, J.3
Coates, A.L.4
Hankinson, J.L.5
Wade, A.M.6
-
8
-
-
69949091227
-
An international collaborative initiative to develop reliable reference ranges for pulmonary function in young children
-
Stanojevic S, Lum S, Wade A, Cole TJ, Custovic A, Silverman M, Stocks J. An international collaborative initiative to develop reliable reference ranges for pulmonary function in young children. Thorax 2006;61:ii94.
-
(2006)
Thorax
, vol.61
-
-
Stanojevic, S.1
Lum, S.2
Wade, A.3
Cole, T.J.4
Custovic, A.5
Silverman, M.6
Stocks, J.7
-
9
-
-
69949085824
-
Collating international reference data for lung function in young children
-
Stanojevic S, Lum S, Wade A, Cole TJ, Custovic A, Silverman M, Stocks J. Collating international reference data for lung function in young children. Eur Respir J 2006;28:834s.
-
(2006)
Eur Respir J
, vol.28
-
-
Stanojevic, S.1
Lum, S.2
Wade, A.3
Cole, T.J.4
Custovic, A.5
Silverman, M.6
Stocks, J.7
-
10
-
-
69949094281
-
International reference ranges for spirometry for young children
-
Stanojevic S, Wade A, Lum S, Cole TJ, Custovic A, Silverman M, Hall GL, Badier M, Nystad W, Stocks J. International reference ranges for spirometry for young children. Eur Respir J 2007;30:723S.
-
(2007)
Eur Respir J
, vol.30
-
-
Stanojevic, S.1
Wade, A.2
Lum, S.3
Cole, T.J.4
Custovic, A.5
Silverman, M.6
Hall, G.L.7
Badier, M.8
Nystad, W.9
Stocks, J.10
-
11
-
-
29244465116
-
Quality control of spirometry: A lesson from the BRONCUS trial
-
DOI 10.1183/09031936.05.00026705
-
Pellegrino R, Decramer M, van Schayck CP, Dekhuijzen PN, Troosters T, van Herwaarden C, Olivieri D, Del Donno M, De Backer W, Lankhorst I, et al. Quality control of spirometry: a lesson from the BRONCUS Trial 1. Eur Respir J 2005;26:1104-1109. (Pubitemid 41829944)
-
(2005)
European Respiratory Journal
, vol.26
, Issue.6
, pp. 1104-1109
-
-
Pellegrino, R.1
Decramer, M.2
Van Schayck, C.P.O.3
Dekhuijzen, P.N.R.4
Troosters, T.5
Van Herwaarden, C.6
Olivieri, D.7
Del Donno, M.8
De Backer, W.9
Lankhorst, I.10
Ardia, A.11
-
12
-
-
0026682977
-
Smoothing reference centile curves: The LMS method and penalized likelihood
-
Cole TJ, Green PJ. Smoothing reference centile curves: the LMS method and penalized likelihood. Stat Med 1992;11:1305-1319.
-
(1992)
Stat Med
, vol.11
, pp. 1305-1319
-
-
Cole, T.J.1
Green, P.J.2
-
13
-
-
0032723509
-
Gender differences in airway behaviour over the human life span
-
Becklake MR, Kaufmann F. Gender differences in airway behaviour over the human life span. Thorax 1999;54:1119-1138.
-
(1999)
Thorax
, vol.54
, pp. 1119-1138
-
-
Becklake, M.R.1
Kaufmann, F.2
-
14
-
-
57149092192
-
Using the lower limit of normal for the FEV1/FVC ratio reduces the misclassification of airway obstruction
-
Swanney MP, Ruppel G, Enright PL, Pedersen OF, Crapo RO, Miller MR, Jensen RL, Falaschetti E, Schouten JP, Hankinson JL, et al. Using the lower limit of normal for the FEV1/FVC ratio reduces the misclassification of airway obstruction. Thorax 2008;63:1046-1051.
-
(2008)
Thorax
, vol.63
, pp. 1046-1051
-
-
Swanney, M.P.1
Ruppel, G.2
Enright, P.L.3
Pedersen, O.F.4
Crapo, R.O.5
Miller, M.R.6
Jensen, R.L.7
Falaschetti, E.8
Schouten, J.P.9
Hankinson, J.L.10
-
15
-
-
56849101926
-
The EPICure study: Comparison of pediatric spirometry in community and laboratory settings
-
Kirkby J, Welsh L, Lum S, Fawke J, Rowell V, Thomas S, Marlow N, Stocks J. The EPICure study: comparison of pediatric spirometry in community and laboratory settings. Pediatr Pulmonol 2008;43:1233-1241.
-
(2008)
Pediatr Pulmonol
, vol.43
, pp. 1233-1241
-
-
Kirkby, J.1
Welsh, L.2
Lum, S.3
Fawke, J.4
Rowell, V.5
Thomas, S.6
Marlow, N.7
Stocks, J.8
-
16
-
-
38049031933
-
Area under the maximum expiratory flow-volume curve: A sensitive parameter in the evaluation of airway patency
-
Zapletal A, Hladikova M, Chalupova J, Svobodova T, Vavrova V. Area under the maximum expiratory flow-volume curve: a sensitive parameter in the evaluation of airway patency. Respiration 2008;75:40-47.
-
(2008)
Respiration
, vol.75
, pp. 40-47
-
-
Zapletal, A.1
Hladikova, M.2
Chalupova, J.3
Svobodova, T.4
Vavrova, V.5
-
17
-
-
36849047791
-
Spirometry in 5-year-olds - Validation of current guidelines and the relation with asthma
-
DOI 10.1002/ppul.20709
-
Turner SW, Craig LC, Harbour PJ, Forbes SH, McNeill G, Seaton A, Devereux G, Helms PJ. Spirometry in 5-year-olds-validation of current guidelines and the relation with asthma. Pediatr Pulmonol 2007;42:1144-1151. (Pubitemid 350231864)
-
(2007)
Pediatric Pulmonology
, vol.42
, Issue.12
, pp. 1144-1151
-
-
Turner, S.W.1
Craig, L.C.A.2
Harbour, P.J.3
Forbes, S.H.4
McNeill, G.5
Seaton, A.6
Devereux, G.7
Helms, P.J.8
-
18
-
-
33746656305
-
Spirometry in 3-5-year-old children with asthma
-
Neve V, Edme JL, Devos P, Deschildre A, Thumerelle C, Santos C, Methlin CM, Matran M, Matran R. Spirometry in 3-5-year-old children with asthma. Pediatr Pulmonol 2006;41:735-743.
-
(2006)
Pediatr Pulmonol
, vol.41
, pp. 735-743
-
-
Neve, V.1
Edme, J.L.2
Devos, P.3
Deschildre, A.4
Thumerelle, C.5
Santos, C.6
Methlin, C.M.7
Matran, M.8
Matran, R.9
-
19
-
-
0036897828
-
Feasibility of measuring lung function in preschool children
-
DOI 10.1136/thorax.57.12.1021
-
Nystad W, Samuelsen SO, Nafstad P, Edvardsen E, Stensrud T, Jaakkola JJ. Feasibility of measuring lung function in preschool children. Thorax 2002;57:1021-1027. (Pubitemid 35440760)
-
(2002)
Thorax
, vol.57
, Issue.12
, pp. 1021-1027
-
-
Nystad, W.1
Samuelsen, S.O.2
Nafstad, P.3
Edvardsen, E.4
Stensrud, T.5
Jaakkola, J.J.K.6
-
20
-
-
33846302759
-
1 performance among patients with acute asthma: Results from a multicenter clinical trial
-
DOI 10.1378/chest.06-0530
-
Silverman RA, Flaster E, Enright PL, Simonson SG. FEV1 performance among patients with acute asthma: results from a multicenter clinical trial. Chest 2007;131:164-171. (Pubitemid 46122989)
-
(2007)
Chest
, vol.131
, Issue.1
, pp. 164-171
-
-
Silverman, R.A.1
Flaster, E.2
Enright, P.L.3
Simonson, S.G.4
-
21
-
-
0034954591
-
Spirometry in children aged 3 to 5 years: Reliability of forced expiratory maneuvers
-
DOI 10.1002/ppul.1089
-
Crenesse D, Berlioz M, Bourrier T, Albertini M. Spirometry in children aged 3 to 5 years: reliability of forced expiratory maneuvers. Pediatr Pulmonol 2001;32:56-61. (Pubitemid 32595360)
-
(2001)
Pediatric Pulmonology
, vol.32
, Issue.1
, pp. 56-61
-
-
Sanders Jr., R.C.1
Thurman, T.L.2
Holt, S.J.3
Taft, K.4
Heulitt, M.J.5
|