메뉴 건너뛰기




Volumn 24, Issue 2, 2009, Pages 275-281

Immediate maxillary restoration of single-tooth implants using platform switching for crestal bone preservation: A 12-Month study

Author keywords

Immediate provisionalization; Platform switching; Resonance frequency analysis

Indexed keywords

ADULT; ARTICLE; CLINICAL TRIAL; DENTAL SURGERY; DENTURE; FEMALE; FOLLOW UP; HUMAN; JAW; MALE; MAXILLA; METHODOLOGY; MIDDLE AGED; PHYSIOLOGY; PROSPECTIVE STUDY; STATISTICAL MODEL; SURVIVAL; TOOTH CROWN; TOOTH IMPLANTATION; TOOTH PROSTHESIS; TOOTH SOCKET; TREATMENT OUTCOME; WEIGHT BEARING; WOUND HEALING;

EID: 69849083235     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (75)

References (25)
  • 1
    • 14844286171 scopus 로고    scopus 로고
    • Dimensional ridge alterations following tooth extraction. An experimental study in the dog
    • DOI 10.1111/j.1600-051X.2005.00642.x
    • Araújo MG, Lindhe J. Dimensional ridge alterations following tooth extraction. An experimental study in the dog.J Clin Periodontol 2005;32:212-218. (Pubitemid 40341858)
    • (2005) Journal of Clinical Periodontology , vol.32 , Issue.2 , pp. 212-218
    • Araujo, M.G.1    Lindhe, J.2
  • 3
    • 34548674664 scopus 로고    scopus 로고
    • A prospective clinical study of non-submerged immediate implants: Clinical outcomes and esthetic results
    • Chen ST, Darby IB, Reynolds EC. A prospective clinical study of non-submerged immediate implants: Clinical outcomes and esthetic results.Clin Oral Implants Res 2007;18:552-562.
    • (2007) Clin Oral Implants Res , vol.18 , pp. 552-562
    • Chen, S.T.1    Darby, I.B.2    Reynolds, E.C.3
  • 4
    • 0030253561 scopus 로고    scopus 로고
    • Dimension of the periimplant mucosa Biological width revisited
    • Berglundh T, Lindhe J. Dimension of the periimplant mucosa. Biological width revisited.J Clin Periodontol 1996;23:971-973.
    • (1996) J Clin Periodontol , vol.23 , pp. 971-973
    • Berglundh, T.1    Lindhe, J.2
  • 5
    • 0031262411 scopus 로고    scopus 로고
    • Crestal Bone Changes Around Titanium Implants. A Radiographic Evaluation of Unloaded Nonsubmerged and Submerged Implants in the Canine Mandible
    • Hermann JS, Cochran DL, Nummikoski PV, Buser D.Crestal bone changes around titanium implants. A radiographic evaluation of unloaded nonsubmerged and submerged implants in the canine mandible. J Periodontol 1997;68:1117-1130. (Pubitemid 127513679)
    • (1997) Journal of Periodontology , vol.68 , Issue.11 , pp. 1117-1130
    • Hermann, J.S.1    Cochran, D.L.2    Nummikoski, P.V.3    Buser, D.4
  • 6
    • 0031067775 scopus 로고    scopus 로고
    • Biologic width around titanium implants. A histometric analysis of the implanto-gingival junction around unloaded and loaded non-submerged implants in the canine mandible
    • Cochran DL, Hermann JS, Schenk RK, Higginbottom FL, Buser D. Biologic width around titanium implants. A histometric analysis of the implanto-gingival junction around unloaded and loaded non-submerged implants in the canine mandible. J Periodontol 1997;68:186-198.
    • (1997) J Periodontol , vol.68 , pp. 186-198
    • Cochran, D.L.1    Hermann, J.S.2    Schenk, R.K.3    Higginbottom, F.L.4    Buser, D.5
  • 8
    • 0035406015 scopus 로고    scopus 로고
    • Cochran DLCrestal bone changes around titanium implants: A methodologic study comparing linear radiographic with histometric measurements
    • Hermann JS, Schoolfield JD, Nummikoski PV, Buser D, Schenk RK, Cochran DLCrestal bone changes around titanium implants: A methodologic study comparing linear radiographic with histometric measurements. Int J Oral Maxillofac Implants 2001;16:475-485.
    • (2001) Int J Oral Maxillofac Implants , vol.16 , pp. 475-485
    • Hermann, J.S.1    Schoolfield, J.D.2    Nummikoski, P.V.3    Buser, D.4    Schenk, R.K.5
  • 9
    • 31944431959 scopus 로고    scopus 로고
    • Platform switching. A new concept in implant dentistry for controlling post-restorative bone levels
    • Lazzara RJ, Porter SS. Platform switching. A new concept in implant dentistry for controlling post-restorative bone levels. Int J Periodontics Restorative Dent 2006;26:9-17.
    • (2006) Int J Periodontics Restorative Dent , vol.26 , pp. 9-17
    • Lazzara, R.J.1    Porter, S.S.2
  • 10
    • 0842280595 scopus 로고    scopus 로고
    • Vertical distance from the crest of bone to the height of the interproximal papilla between adjacent implants
    • Tarnow D, Elian N, Fletcher P, et al.Vertical distance from the crest of bone to the height of the interproximal papilla between adjacent implants.J Periodontol 2003;74:1785-1788.
    • (2003) J Periodontol , vol.74 , pp. 1785-1788
    • Tarnow, D.1    Elian, N.2    Fletcher, P.3
  • 11
    • 0027013273 scopus 로고
    • The effect of the distance from the contact point to the crest of bone on the presence of absence of the interproximal dental papilla
    • Tarnow DP, Magner AW, Fletcher P.The effect of the distance from the contact point to the crest of bone on the presence of absence of the interproximal dental papilla. J Periodontol 1992;63:995-996.
    • (1992) J Periodontol , vol.63 , pp. 995-996
    • Tarnow, D.P.1    Magner, A.W.2    Fletcher, P.3
  • 12
    • 23244459334 scopus 로고    scopus 로고
    • Platform switching as a means to achieving implant esthetics A case study
    • Gardner DM. Platform switching as a means to achieving implant esthetics. A case study. NY State Dent J 2005;71:34-37.
    • (2005) NY State Dent J , vol.71 , pp. 34-37
    • Gardner, D.M.1
  • 14
    • 33748309280 scopus 로고    scopus 로고
    • Validity and clinical significance of biomechanical testing of implant/bone interface
    • AparicioC.Lang NP.Rangert B. Validity and clinical significance of biomechanical testing of implant/bone interface. Clin Oral Implants Res 2006;17(suppt 2):2-7.
    • (2006) Clin Oral Implants Res , vol.17 , Issue.SUPPT 2 , pp. 2-7
    • Aparicio, C.1    Lang, N.P.2    Rangert, B.3
  • 17
    • 38149054263 scopus 로고    scopus 로고
    • Preservation of peri-implant soft and hard tissues using platform switching of implants placed in immediate extraction sockets: A proof-of-concept study with 12- to 36-month follow-up
    • Canullo L, Rasperini G. Preservation of peri-implant soft and hard tissues using platform switching of implants placed in immediate extraction sockets: A proof-of-concept study with 12- to 36-month follow-up. Int J Oral Maxillofac Implants 2007;22:995-1000.
    • (2007) Int J Oral Maxillofac Implants , vol.22 , pp. 995-1000
    • Canullo, L.1    Rasperini, G.2
  • 18
    • 0031180549 scopus 로고    scopus 로고
    • A comparison of radiographic bone height and probing attachment level measurements adjacent to porous-coated dental implants in humans
    • Levy D, Deporter DA, Pharoah M,Tomlinson G. A comparison of radiographic bone height and probing attachment level measurements adjacent to porous-coated dental implants in humans. Int J Oral Maxillofac Implants 1997;12:541-546.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 541-546
    • Levy, D.1    Deporter, D.A.2    Pharoah Mtomlinson, G.3
  • 20
    • 33744474296 scopus 로고    scopus 로고
    • Peri-implant inflammation defined by the implant-abutment interface
    • Broggini N, McManus LM, Hermann JS, et al. Peri-implant inflammation defined by the implant-abutment interface. J Dent Res 2006;85:473-478.
    • (2006) J Dent Res , vol.85 , pp. 473-478
    • Broggini, N.1    McManus, L.M.2    Hermann, J.S.3
  • 21
    • 0034171352 scopus 로고    scopus 로고
    • The effect of inter-implant stance on the height of inter-implant bone crest
    • Tarnow DP, Cho SC, Wallace SS.The effect of inter-implant stance on the height of inter-implant bone crest. J Periodontol 2000;71:546-549.
    • (2000) J Periodontol , vol.71 , pp. 546-549
    • Tarnow, D.P.1    Cho, S.C.2    Wallace, S.S.3
  • 22
    • 6344239043 scopus 로고    scopus 로고
    • Hard-tissue alterations following immediate implant placement in extraction sites
    • Botticelli D, Berglundh T, Lindhe J. Hard-tissue alterations following immediate implant placement in extraction sites. J Clin Periodontol 2004;31:820-828.
    • (2004) J Clin Periodontol , vol.31 , pp. 820-828
    • Botticelli, D.1    Berglundh, T.2    Lindhe, J.3
  • 23
    • 2442526473 scopus 로고    scopus 로고
    • Initial implant position determines the magnitude of crestal bone remodeling
    • Hartman GA, Cochran DL. Initial implant position determines the magnitude of crestal bone remodeling.J Periodontol 2004;75:572-577.
    • (2004) J Periodontol , vol.75 , pp. 572-577
    • Hartman, G.A.1    Cochran, D.L.2
  • 24
    • 0034139628 scopus 로고    scopus 로고
    • Immediate functional loading of Branemark single tooth implants An 18-month clinical pilot follow-up study
    • Ericsson I, Nilson H, Lindh T, Nilner K, Randow K. Immediate functional loading of Branemark single tooth implants. An 18-month clinical pilot follow-up study. Clin Oral Implants Res 2000;11:26-33.
    • (2000) Clin Oral Implants Res , vol.11 , pp. 26-33
    • Ericsson, I.1    Nilson, H.2    Lindh, T.3    Nilner, K.4    Randow, K.5
  • 25
    • 0042513564 scopus 로고    scopus 로고
    • Immediate occlusal loading of Brånemark TiUnite implants placed predominantly in soft bone: 1-year results of a prospective clinical study
    • Glauser R, Lundgren AK, Gottlow J, et al. Immediate occlusal loading of Brånemark TiUnite implants placed predominantly in soft bone: 1-year results of a prospective clinical study. Clin Implant Dent Relat Res 2003;5 (suppl 1):47-56.
    • (2003) Clin Implant Dent Relat Res , vol.5 , Issue.SUPPL. 1 , pp. 47-56
    • Glauser, R.1    Lundgren, A.K.2    Gottlow, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.