메뉴 건너뛰기




Volumn 75, Issue 2, 2009, Pages 603-610

Image-Guided Radiotherapy in Near Real Time With Intensity-Modulated Radiotherapy Megavoltage Treatment Beam Imaging

Author keywords

EPID; Fiducial marker; IGRT; Prostate; Real time tracking

Indexed keywords

EPID; FIDUCIAL MARKER; IGRT; PROSTATE; REAL-TIME TRACKING;

EID: 69549128103     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2009.04.068     Document Type: Article
Times cited : (27)

References (18)
  • 1
    • 0035889335 scopus 로고    scopus 로고
    • Intensity-modulated radiotherapy: Current status and issues of interest
    • IMRT Collaborative Working Group
    • IMRT Collaborative Working Group. Intensity-modulated radiotherapy: Current status and issues of interest. Int J Radiat Oncol Biol Phys 51 (2001) 880-914
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , pp. 880-914
  • 2
    • 12144289319 scopus 로고    scopus 로고
    • Implementing IMRT in clinical practice: A joint document of the American Society for Therapeutic Radiology and Oncology and the American Association of Physicists in Medicine
    • Galvin J.M., Ezzell G., Eisbrauch A., et al. Implementing IMRT in clinical practice: A joint document of the American Society for Therapeutic Radiology and Oncology and the American Association of Physicists in Medicine. Int J Radiat Oncol Biol Phys 58 (2004) 1616-1634
    • (2004) Int J Radiat Oncol Biol Phys , vol.58 , pp. 1616-1634
    • Galvin, J.M.1    Ezzell, G.2    Eisbrauch, A.3
  • 3
    • 0028797095 scopus 로고
    • Measurement of prostate movement over the course of routine radiotherapy using implanted markers
    • Balter J.M., Sandler H.M., Lam K., et al. Measurement of prostate movement over the course of routine radiotherapy using implanted markers. Int J Radiat Oncol Biol Phys 31 (1995) 113-118
    • (1995) Int J Radiat Oncol Biol Phys , vol.31 , pp. 113-118
    • Balter, J.M.1    Sandler, H.M.2    Lam, K.3
  • 4
    • 0142186646 scopus 로고    scopus 로고
    • Technical aspects of daily online positioning of the prostate for three-dimensional conformal radiotherapy using an electronic portal imaging device
    • Herman M.G., Pisansky T.M., Kruse J.J., et al. Technical aspects of daily online positioning of the prostate for three-dimensional conformal radiotherapy using an electronic portal imaging device. Int J Radiat Oncol Biol Phys 57 (2003) 1131-1140
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , pp. 1131-1140
    • Herman, M.G.1    Pisansky, T.M.2    Kruse, J.J.3
  • 5
    • 21044457706 scopus 로고    scopus 로고
    • Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI)
    • Ghilezan M.J., Jaffray D.A., Siewerdsen J.H., et al. Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI). Int J Radiat Oncol Biol Phys 62 (2005) 406-417
    • (2005) Int J Radiat Oncol Biol Phys , vol.62 , pp. 406-417
    • Ghilezan, M.J.1    Jaffray, D.A.2    Siewerdsen, J.H.3
  • 6
    • 33847328730 scopus 로고    scopus 로고
    • Multi-institutional clinical experience with the Calypso System in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy
    • Kupelian P., Willoughby T., Mahadevan A., et al. Multi-institutional clinical experience with the Calypso System in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy. Int J Radiat Oncol Biol Phys 67 (2007) 1088-1098
    • (2007) Int J Radiat Oncol Biol Phys , vol.67 , pp. 1088-1098
    • Kupelian, P.1    Willoughby, T.2    Mahadevan, A.3
  • 7
    • 0842349454 scopus 로고    scopus 로고
    • Tracking moving organs in real time
    • Murphy M.J. Tracking moving organs in real time. Semin Radiat Oncol 14 (2004) 91-100
    • (2004) Semin Radiat Oncol , vol.14 , pp. 91-100
    • Murphy, M.J.1
  • 8
    • 33645347668 scopus 로고    scopus 로고
    • Overview of image-guided radiation therapy
    • Xing L., Thorndyke B., Schreibmann E., et al. Overview of image-guided radiation therapy. Med Dosim 31 (2006) 91-112
    • (2006) Med Dosim , vol.31 , pp. 91-112
    • Xing, L.1    Thorndyke, B.2    Schreibmann, E.3
  • 9
    • 0036680531 scopus 로고    scopus 로고
    • Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions
    • Kitamura K., Shirato H., Seppenwoolde Y., et al. Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions. Int J Radiat Oncol Biol Phys 53 (2002) 1117-1123
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 1117-1123
    • Kitamura, K.1    Shirato, H.2    Seppenwoolde, Y.3
  • 10
    • 49549093853 scopus 로고    scopus 로고
    • Intrafractional motion of the prostate during hypofractionated radiotherapy
    • Xie Y., Djajaputra D., King C.R., et al. Intrafractional motion of the prostate during hypofractionated radiotherapy. Int J Radiat Oncol Biol Phys 72 (2008) 236-246
    • (2008) Int J Radiat Oncol Biol Phys , vol.72 , pp. 236-246
    • Xie, Y.1    Djajaputra, D.2    King, C.R.3
  • 11
    • 34548474887 scopus 로고    scopus 로고
    • Intrafraction motion of the prostate during external-beam radiation therapy: Analysis of 427 patients with implanted fiducial markers
    • Kotte A.N., Hofman P., Lagendijk J.J., et al. Intrafraction motion of the prostate during external-beam radiation therapy: Analysis of 427 patients with implanted fiducial markers. Int J Radiat Oncol Biol Phys 69 (2007) 419-425
    • (2007) Int J Radiat Oncol Biol Phys , vol.69 , pp. 419-425
    • Kotte, A.N.1    Hofman, P.2    Lagendijk, J.J.3
  • 12
    • 48349123436 scopus 로고    scopus 로고
    • A fiducial detection algorithm for real-time image guided IMRT based on simultaneous MV and kV imaging
    • Mao W., Riaz N., Lee L., et al. A fiducial detection algorithm for real-time image guided IMRT based on simultaneous MV and kV imaging. Med Phys 35 (2008) 3554-3564
    • (2008) Med Phys , vol.35 , pp. 3554-3564
    • Mao, W.1    Riaz, N.2    Lee, L.3
  • 13
    • 42949137874 scopus 로고    scopus 로고
    • Fast internal marker tracking algorithm for onboard MV and kV imaging systems
    • Mao W., Wiersma R.D., and Xing L. Fast internal marker tracking algorithm for onboard MV and kV imaging systems. Med Phys 35 (2008) 1942-1949
    • (2008) Med Phys , vol.35 , pp. 1942-1949
    • Mao, W.1    Wiersma, R.D.2    Xing, L.3
  • 14
    • 41449117460 scopus 로고    scopus 로고
    • Development of a QA phantom and automated analysis tool for geometric quality assurance of on-board MV and kV x-ray imaging systems
    • Mao W., Lee L., and Xing L. Development of a QA phantom and automated analysis tool for geometric quality assurance of on-board MV and kV x-ray imaging systems. Med Phys 34 (2008) 1497-1506
    • (2008) Med Phys , vol.34 , pp. 1497-1506
    • Mao, W.1    Lee, L.2    Xing, L.3
  • 15
    • 45449088673 scopus 로고    scopus 로고
    • Observations on real-time prostate gland motion using electromagnetic tracking
    • Langen K.M., Willoughby T.R., Meeks S.L., et al. Observations on real-time prostate gland motion using electromagnetic tracking. Int J Radiat Oncol Biol Phys 71 (2008) 1084-1090
    • (2008) Int J Radiat Oncol Biol Phys , vol.71 , pp. 1084-1090
    • Langen, K.M.1    Willoughby, T.R.2    Meeks, S.L.3
  • 16
    • 0141670416 scopus 로고    scopus 로고
    • Segment-based dose optimization using a genetic algorithm
    • Cotrutz C., and Xing L. Segment-based dose optimization using a genetic algorithm. Phys Med Biol 48 (2003) 2987-2998
    • (2003) Phys Med Biol , vol.48 , pp. 2987-2998
    • Cotrutz, C.1    Xing, L.2
  • 17
    • 0035989958 scopus 로고    scopus 로고
    • Direct aperture optimization: A turnkey solution for step-and-shoot IMRT
    • Shepard D.M., Earl M.A., Li X.A., et al. Direct aperture optimization: A turnkey solution for step-and-shoot IMRT. Med Phys 29 (2002) 1007-1018
    • (2002) Med Phys , vol.29 , pp. 1007-1018
    • Shepard, D.M.1    Earl, M.A.2    Li, X.A.3
  • 18
    • 41449112602 scopus 로고    scopus 로고
    • Combined kV and MV imaging for real-time tracking of implanted fiducial markers
    • Wiersma R.D., Mao W., and Xing L. Combined kV and MV imaging for real-time tracking of implanted fiducial markers. Med Phys 35 (2008) 1191-1198
    • (2008) Med Phys , vol.35 , pp. 1191-1198
    • Wiersma, R.D.1    Mao, W.2    Xing, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.