메뉴 건너뛰기




Volumn 73, Issue 9, 2009, Pages 1606-1611

Vagal modification can be a valid predictor of late recurrence of paroxysmal atrial fibrillation independent of the pulmonary vein isolation technique

Author keywords

Atrial fibrillation; Autonomic nervous system; Heart rate variability; Pulmonary vein isolation; Radiofrequency catheter ablation

Indexed keywords

ADULT; AGED; ARTICLE; CATHETER ABLATION; FEMALE; FOLLOW UP; FREQUENCY ANALYSIS; HEART ATRIUM FIBRILLATION; HEART DENERVATION; HEART RATE VARIABILITY; HOLTER MONITORING; HUMAN; INCIDENCE; MAJOR CLINICAL STUDY; MALE; PARASYMPATHETIC TONE; PREDICTOR VARIABLE; PULMONARY VEIN ISOLATION TECHNIQUE; RECURRENT DISEASE; SYMPATHETIC TONE; VAGUS TONE;

EID: 69549121552     PISSN: 13469843     EISSN: 13474820     Source Type: Journal    
DOI: 10.1253/circj.CJ-09-0158     Document Type: Article
Times cited : (26)

References (29)
  • 3
    • 10044263163 scopus 로고    scopus 로고
    • Pulmonary vein antrum isolation: Intracardiac echocardiography-guided technique
    • DOI 10.1046/j.1540-8167.2004.04428.x
    • Verma A, Marrouche NF, Natale A. Pulmonary vein antrum isolation: Intracardiac echocardiography-guided technique. J Cardiovasc Electrophysiol 2004; 15: 1335-1340. (Pubitemid 39612646)
    • (2004) Journal of Cardiovascular Electrophysiology , vol.15 , Issue.11 , pp. 1335-1340
    • Verma, A.1    Marrouche, N.F.2    Natale, A.3
  • 6
    • 33645864932 scopus 로고    scopus 로고
    • Electrophysiological pulmonary vein antrum isolation with a multielectrode basket catheter is feasible and effective for curing paroxysmal atrial fibrillation: Efficacy of minimally extensive pulmonary vein isolation
    • Yamada T, Murakami Y, Okada T, Okamoto M, Shimizu T, Toyama J, et al. Electrophysiological pulmonary vein antrum isolation with a multielectrode basket catheter is feasible and effective for curing paroxysmal atrial fibrillation: Efficacy of minimally extensive pulmonary vein isolation. Heart Rhythm 2006; 3: 377-384.
    • (2006) Heart Rhythm , vol.3 , pp. 377-384
    • Yamada, T.1    Murakami, Y.2    Okada, T.3    Okamoto, M.4    Shimizu, T.5    Toyama, J.6
  • 11
    • 33845187796 scopus 로고    scopus 로고
    • Effects of circumferential or segmental pulmonary vein ablation for paroxysmal atrial fibrillation on cardiac autonomic function
    • DOI 10.1016/j.hrthm.2006.08.025, PII S1547527106019357
    • Bauer A, Deisenhofer I, Schneider R, Zrenner B, Barthel P, Karch M, et al. Effects of circumferential or segmental pulmonary vein ablation for paroxysmal atrial fibrillation on cardiac autonomic function. Heart Rhythm 2006; 3: 1428-1435. (Pubitemid 44849377)
    • (2006) Heart Rhythm , vol.3 , Issue.12 , pp. 1428-1435
    • Bauer, A.1    Deisenhofer, I.2    Schneider, R.3    Zrenner, B.4    Barthel, P.5    Karch, M.6    Wagenpfeil, S.7    Schmitt, C.8    Schmidt, G.9
  • 12
    • 65649139946 scopus 로고    scopus 로고
    • Vagal modification can also help prevent late recurrence of atrial fibrillation after segmental pulmonary vein isolation
    • Yoshida N, Yamada T, Murakami Y, Okada T, Ninomiya Y, Toyama J, et al. Vagal modification can also help prevent late recurrence of atrial fibrillation after segmental pulmonary vein isolation. Circ J 2009; 73: 632-638.
    • (2009) Circ J , vol.73 , pp. 632-638
    • Yoshida, N.1    Yamada, T.2    Murakami, Y.3    Okada, T.4    Ninomiya, Y.5    Toyama, J.6
  • 13
    • 34250778398 scopus 로고    scopus 로고
    • Electrophysiologic characteristics and outcome of segmental ostial superior vena cava isolation in patients with paroxysmal atrial fibrillation initiated by superior vena cava ectopy: Comparison with pulmonary vein isolation
    • DOI 10.1016/j.jelectrocard.2006.11.010, PII S0022073606005188
    • Muto M, Yamada T, Murakami Y, Okada T, Okamoto M, Shimizu T, et al. Electrophysiologic characteristics and outcome of segmental ostial superior vena cava isolation in patients with paroxysmal atrial fibrillation initiated by superior vena cava ectopy: Comparison with pulmonary vein isolation. J Electrocardiol 2007; 40: 319-325. (Pubitemid 46961996)
    • (2007) Journal of Electrocardiology , vol.40 , Issue.4 , pp. 319-325
    • Muto, M.1    Yamada, T.2    Murakami, Y.3    Okada, T.4    Okamoto, M.5    Shimizu, T.6    Toyama, J.7    Yoshida, Y.8    Tsuboi, N.9    Ito, T.10    Kondo, T.11    Inden, Y.12    Hirai, M.13    Murohara, T.14
  • 15
    • 0029928495 scopus 로고    scopus 로고
    • Heart rate variability: Standards of measurements, physiological interpretation, and clinical use
    • Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology
    • Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology. Heart rate variability: Standards of measurements, physiological interpretation, and clinical use. Circulation 1996; 93: 1043-1065.
    • (1996) Circulation , vol.93 , pp. 1043-1065
  • 16
    • 1642398327 scopus 로고    scopus 로고
    • Resumption of electrical conduction in previously isolated pulmonary veins: Rationale for a different strategy?
    • Nanthakumar K, Plumb VJ, Epstein AE, Veenhuyzen GD, Link D, Kay GN. Resumption of electrical conduction in previously isolated pulmonary veins: Rationale for a different strategy? Circulation 2004; 109: 1226-1229.
    • (2004) Circulation , vol.109 , pp. 1226-1229
    • Nanthakumar, K.1    Plumb, V.J.2    Epstein, A.E.3    Veenhuyzen, G.D.4    Link, D.5    Kay, G.N.6
  • 17
    • 0141618302 scopus 로고    scopus 로고
    • Prospective assessment of late conduction recurrence across radiofrequency lesions producing electrical disconnection at the pulmonary vein ostium in patients with atrial fibrillation
    • DOI 10.1161/01.CIR.0000091081.19465.F1
    • Cappato R, Negroni S, Pecora D, Bentivegna S, Lupo PP, Carolei A, et al. Prospective assessment of late conduction recurrence across radiofrequency lesions producing electrical disconnection at the pulmonary vein ostium in patients with atrial fibrillation. Circulation 2003; 108: 1599-1604. (Pubitemid 37187787)
    • (2003) Circulation , vol.108 , Issue.13 , pp. 1599-1604
    • Cappato, R.1    Negroni, S.2    Pecora, D.3    Bentivegna, S.4    Lupo, P.P.5    Carolei, A.6    Esposito, C.7    Furlanello, F.8    De Ambroggi, L.9
  • 19
    • 24944455932 scopus 로고    scopus 로고
    • Predictors of non-pulmonary vein ectopic beats initiating paroxysmal atrial fibrillation: Implication for catheter ablation
    • Lee SH, Tai CT, Hsieh MH, Tsao HM, Lin YJ, Chang SL, et al. Predictors of non-pulmonary vein ectopic beats initiating paroxysmal atrial fibrillation: Implication for catheter ablation. J Am Coll Cardiol 2005; 46: 1054-1059.
    • (2005) J Am Coll Cardiol , vol.46 , pp. 1054-1059
    • Lee, S.H.1    Tai, C.T.2    Hsieh, M.H.3    Tsao, H.M.4    Lin, Y.J.5    Chang, S.L.6
  • 21
    • 0037062699 scopus 로고    scopus 로고
    • Autonomic tone variations before the onset of paroxysmal atrial fibrillation
    • DOI 10.1161/01.CIR.0000018443.44005.D8
    • Bettoni M, Zimmermann M. Autonomic tone variations before the onset of paroxysmal atrial fibrillation. Circulation 2002; 105: 2753-2759. (Pubitemid 34615147)
    • (2002) Circulation , vol.105 , Issue.23 , pp. 2753-2759
    • Bettoni, M.1    Zimmermann, M.2
  • 22
    • 0035100816 scopus 로고    scopus 로고
    • Fluctuation in autonomic tone is a major determinant of sustained atrial arrhythmias in patients with focal ectopy originating from the pulmonary veins
    • Zimmermann M, Kalusche D. Fluctuation in autonomic tone is a major determinant of sustained atrial arrhythmias in patients with focal ectopy originating from the pulmonary veins. J Cardiovasc Electrophysiol 2001; 12: 285-291. (Pubitemid 32225455)
    • (2001) Journal of Cardiovascular Electrophysiology , vol.12 , Issue.3 , pp. 285-291
    • Zimmermann, M.1    Kalusche, D.2
  • 23
    • 58549084577 scopus 로고    scopus 로고
    • Vagal effects on the occurrence of focal atrial fibrillation originating from the pulmonary veins
    • Liu P, Guo JH, Zhang HC, Wang MX, Li XB, Zhang P, et al. Vagal effects on the occurrence of focal atrial fibrillation originating from the pulmonary veins. Circ J 2009; 73: 48-54.
    • (2009) Circ J , vol.73 , pp. 48-54
    • Liu, P.1    Guo, J.H.2    Zhang, H.C.3    Wang, M.X.4    Li, X.B.5    Zhang, P.6
  • 25
    • 0022640679 scopus 로고
    • The wavelength of the cardiac impulse and reentrant arrhythmias in isolated rabbit atrium: The role of heart rate, autonomic transmitters, temperature, and potassium
    • Smeets JL, Allessie MA, Lammers WJ, Bonke FI, Hollen J. The wavelength of the cardiac impulse and reentrant arrhythmias in isolated rabbit atrium: The role of heart rate, autonomic transmitters, temperature, and potassium. Circ Res 1986; 58: 96-108.
    • (1986) Circ Res , vol.58 , pp. 96-108
    • Smeets, J.L.1    Allessie, M.A.2    Lammers, W.J.3    Bonke, F.I.4    Hollen, J.5
  • 26
    • 85047677725 scopus 로고
    • Effects of selective vagal and stellate ganglion stimulation on atrial refractoriness
    • Zipes DP, Mihalick MJ, Robbins GT. Effects of selective vagal and stellate ganglion stimulation on atrial refractoriness. Cardiovasc Res 1974; 8: 647-655.
    • (1974) Cardiovasc Res , vol.8 , pp. 647-655
    • Zipes, D.P.1    Mihalick, M.J.2    Robbins, G.T.3
  • 27
  • 28
    • 22544473370 scopus 로고    scopus 로고
    • Perception of atrial fibrillation before and after radiofrequency catheter ablation: Relevance of asymptomatic arrhythmia recurrence
    • DOI 10.1161/CIRCULATIONAHA.104.518837
    • Hindricks G, Piorkowski C, Tanner H, Kobza R, Gerds-Li JH, Carbucicchio C, et al. Perception of atrial fibrillation before and after radiofrequency catheter ablation: Relevance of asymptomatic arrhythmia recurrence. Circulation 2005; 112: 307-313. (Pubitemid 41022070)
    • (2005) Circulation , vol.112 , Issue.3 , pp. 307-313
    • Hindricks, G.1    Piorkowski, C.2    Tanner, H.3    Kobza, R.4    Gerds-Li, J.-H.5    Carbucicchio, C.6    Kottkamp, H.7
  • 29
    • 33644864507 scopus 로고    scopus 로고
    • Value of different follow-up strategies to assess the efficacy of circumferential pulmonary vein ablation for the curative treatment of atrial fibrillation
    • DOI 10.1111/j.1540-8167.2005.00245.x
    • Piorkowski C, Kottkamp H, Tanner H, Kobza R, Nielsen JC, Arya A, et al. Value of different follow-up strategies to assess the efficacy of circumferential pulmonary vein ablation for the curative treatment of atrial fibrillation. J Cardiovasc Electrophysiol 2005; 16: 1286-1292. (Pubitemid 43919969)
    • (2005) Journal of Cardiovascular Electrophysiology , vol.16 , Issue.12 , pp. 1286-1292
    • Piorkowski, C.1    Kottkamp, H.2    Tanner, H.3    Kobza, R.4    Nielsen, J.C.5    Arya, A.6    Hindricks, G.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.