메뉴 건너뛰기




Volumn 71, Issue 9, 2007, Pages 1430-1436

Pulmonary vein antrum not always coaxial to the pulmonary vein - A dimensional pitfall to the circumferential isolation technique

Author keywords

Atrial fibrillation; Multielectrode basket catheter; Non coaxial; Pulmonary vein antrum; Radiofrequency catheter ablation

Indexed keywords

ANTIARRHYTHMIC AGENT;

EID: 34548480716     PISSN: 13469843     EISSN: 13474820     Source Type: Journal    
DOI: 10.1253/circj.71.1430     Document Type: Article
Times cited : (4)

References (19)
  • 1
    • 0032480265 scopus 로고    scopus 로고
    • Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins
    • Haissaguerre M, Jais P, Shah DC, Takahashi A, Hocini M, Quiniou G, et al. Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med 1998; 339: 659-666.
    • (1998) N Engl J Med , vol.339 , pp. 659-666
    • Haissaguerre, M.1    Jais, P.2    Shah, D.C.3    Takahashi, A.4    Hocini, M.5    Quiniou, G.6
  • 2
    • 0033517860 scopus 로고    scopus 로고
    • Initiation of atrial fibrillation by ectopic beats originating from pulmonary veins: Electrophysiologic characteristics, pharmacologic responses, and effects of radiofrequency ablation
    • Chen SA, Hsieh MH, Tai CT, Prakash VS, Yu WC, Hsu TL, et al. Initiation of atrial fibrillation by ectopic beats originating from pulmonary veins: Electrophysiologic characteristics, pharmacologic responses, and effects of radiofrequency ablation. Circulation 1999; 100: 1879-1886.
    • (1999) Circulation , vol.100 , pp. 1879-1886
    • Chen, S.A.1    Hsieh, M.H.2    Tai, C.T.3    Prakash, V.S.4    Yu, W.C.5    Hsu, T.L.6
  • 4
    • 29744459487 scopus 로고    scopus 로고
    • New approach to pulmonary vein isolation for atrial fibrillation using a multielectrode basket catheter
    • Kumagai K, Noguchi H, Ogawa M, Nakashima H, Zhang B, Miura S, et al. New approach to pulmonary vein isolation for atrial fibrillation using a multielectrode basket catheter. Circ J 2006; 70: 88-93.
    • (2006) Circ J , vol.70 , pp. 88-93
    • Kumagai, K.1    Noguchi, H.2    Ogawa, M.3    Nakashima, H.4    Zhang, B.5    Miura, S.6
  • 5
    • 33750579076 scopus 로고    scopus 로고
    • Is circumferential pulmonary vein isolation preferable to stepwise segmental pulmonary vein isolation for patients with paroxysmal atrial fibrillation?
    • Liu X, Long D, Dong J, Hu F, Yu R, Tang R, et al. Is circumferential pulmonary vein isolation preferable to stepwise segmental pulmonary vein isolation for patients with paroxysmal atrial fibrillation? Circ J 2006; 70: 1392-1397.
    • (2006) Circ J , vol.70 , pp. 1392-1397
    • Liu, X.1    Long, D.2    Dong, J.3    Hu, F.4    Yu, R.5    Tang, R.6
  • 6
    • 0034700286 scopus 로고    scopus 로고
    • Circumferential radiofrequency ablation of pulmonary vein ostia: A new anatomic approach for curing atrial fibrillation
    • Pappone C, Rosanio S, Oreto G, Tocchi M, Gugliotta F, Vicedomini G, et al. Circumferential radiofrequency ablation of pulmonary vein ostia: A new anatomic approach for curing atrial fibrillation. Circulation 2000; 102: 2619-2628.
    • (2000) Circulation , vol.102 , pp. 2619-2628
    • Pappone, C.1    Rosanio, S.2    Oreto, G.3    Tocchi, M.4    Gugliotta, F.5    Vicedomini, G.6
  • 7
    • 0242694560 scopus 로고    scopus 로고
    • Catheter ablation for paroxysmal atrial fibrillation: Segmental pulmonary vein ostial ablation versus left atrial ablation
    • Oral H, Christoph S, Chugh A, Hall B, Cheung P, Good E, et al. Catheter ablation for paroxysmal atrial fibrillation: Segmental pulmonary vein ostial ablation versus left atrial ablation. Circulation 2003; 108: 2355-2360.
    • (2003) Circulation , vol.108 , pp. 2355-2360
    • Oral, H.1    Christoph, S.2    Chugh, A.3    Hall, B.4    Cheung, P.5    Good, E.6
  • 8
    • 4444376142 scopus 로고    scopus 로고
    • Left atrial tachycardia after circumferential pulmonary vein ablation for atrial fibrillation. Electroanatomic characterization and treatment
    • Mesas CE, Pappone C, Lang CCE, Gugliotta F, Tomita T, Vicedomini G, et al. Left atrial tachycardia after circumferential pulmonary vein ablation for atrial fibrillation. Electroanatomic characterization and treatment. J Am Coll Cardiol 2004; 44: 1071-1079.
    • (2004) J Am Coll Cardiol , vol.44 , pp. 1071-1079
    • Mesas, C.E.1    Pappone, C.2    Lang, C.C.E.3    Gugliotta, F.4    Tomita, T.5    Vicedomini, G.6
  • 9
    • 2942519274 scopus 로고    scopus 로고
    • Atrio-esophageal fistula as a complication of percutaneous transcatheter ablation of atrial fibrillation
    • Pappone C, Oral H, Santinelli V, Vicedomini G, Lang CC, Manguso F, et al. Atrio-esophageal fistula as a complication of percutaneous transcatheter ablation of atrial fibrillation. Circulation 2004; 109: 2724-2726.
    • (2004) Circulation , vol.109 , pp. 2724-2726
    • Pappone, C.1    Oral, H.2    Santinelli, V.3    Vicedomini, G.4    Lang, C.C.5    Manguso, F.6
  • 10
    • 10044263163 scopus 로고    scopus 로고
    • Pulmonary vein antrum isolation: Intracardiac echocardiography-guided technique
    • Verma A, Marrouche NF, Natale A. Pulmonary vein antrum isolation: Intracardiac echocardiography-guided technique. J Cardiovasc Electrophysiol 2004; 15: 1335-1340.
    • (2004) J Cardiovasc Electrophysiol , vol.15 , pp. 1335-1340
    • Verma, A.1    Marrouche, N.F.2    Natale, A.3
  • 11
    • 33645864932 scopus 로고    scopus 로고
    • Electrophysiological pulmonary vein antrum isolation with a multielectrode basket catheter is feasible and effective for curing paroxysmal atrial fibrillation: Efficacy of minimally extensive pulmonary vein isolation
    • Yamada T, Murakami Y, Okada T, Okamoto M, Shimizu T, Toyama J, et al. Electrophysiological pulmonary vein antrum isolation with a multielectrode basket catheter is feasible and effective for curing paroxysmal atrial fibrillation: Efficacy of minimally extensive pulmonary vein isolation. Heart Rhythm 2006; 3: 377-384.
    • (2006) Heart Rhythm , vol.3 , pp. 377-384
    • Yamada, T.1    Murakami, Y.2    Okada, T.3    Okamoto, M.4    Shimizu, T.5    Toyama, J.6
  • 12
    • 0043075797 scopus 로고    scopus 로고
    • Evidence for longitudinal and transverse fiber conduction in human pulmonary veins: Relevance for catheter ablation
    • Sanchez JE, Plumb VJ, Epstein AE, Kay GN. Evidence for longitudinal and transverse fiber conduction in human pulmonary veins: Relevance for catheter ablation. Circulation 2003; 108: 590-597.
    • (2003) Circulation , vol.108 , pp. 590-597
    • Sanchez, J.E.1    Plumb, V.J.2    Epstein, A.E.3    Kay, G.N.4
  • 14
    • 0034680347 scopus 로고    scopus 로고
    • First human experience with pulmonary vein isolation using a through-the-balloon circumferential ultrasound ablation system for recurrent atrial fibrillation
    • Natale A, Pisano E, Shewchik J, Bash D, Fanelli R, Potenza D, et al. First human experience with pulmonary vein isolation using a through-the-balloon circumferential ultrasound ablation system for recurrent atrial fibrillation. Circulation 2000; 102: 1879-1882.
    • (2000) Circulation , vol.102 , pp. 1879-1882
    • Natale, A.1    Pisano, E.2    Shewchik, J.3    Bash, D.4    Fanelli, R.5    Potenza, D.6
  • 15
    • 0038307096 scopus 로고    scopus 로고
    • Usefulness of a new radiofrequency thermal balloon catheter for pulmonary vein isolation: A new device for treatment of atrial fibrillation
    • Satake S, Tanaka K, Saito S, Tanaka S, Sohara H, Hiroe Y, et al. Usefulness of a new radiofrequency thermal balloon catheter for pulmonary vein isolation: A new device for treatment of atrial fibrillation. J Cardiovasc Electrophysiol 2003; 14: 609-615.
    • (2003) J Cardiovasc Electrophysiol , vol.14 , pp. 609-615
    • Satake, S.1    Tanaka, K.2    Saito, S.3    Tanaka, S.4    Sohara, H.5    Hiroe, Y.6
  • 16
    • 0037532650 scopus 로고    scopus 로고
    • Initial experience with a novel focused ultrasound ablation system for ring ablation outside the pulmonary vein
    • Meininger GR, Calkins H, Lickfett L, Lopath P, Fjield T, Pacheco R, et al. Initial experience with a novel focused ultrasound ablation system for ring ablation outside the pulmonary vein. J Interv Card Electrophysiol 2003; 8: 141-148.
    • (2003) J Interv Card Electrophysiol , vol.8 , pp. 141-148
    • Meininger, G.R.1    Calkins, H.2    Lickfett, L.3    Lopath, P.4    Fjield, T.5    Pacheco, R.6
  • 17
    • 9144272549 scopus 로고    scopus 로고
    • Use of a diode laser balloon ablation catheter to generate circumferential pulmonary venous lesions in an open-thoracotomy caprine model
    • Reddy VY, Houghtaling C, Fallon J, Fischer G, Farr N, Clarke J, et al. Use of a diode laser balloon ablation catheter to generate circumferential pulmonary venous lesions in an open-thoracotomy caprine model. Pacing Clin Electrophysiol 2004; 27: 52-57.
    • (2004) Pacing Clin Electrophysiol , vol.27 , pp. 52-57
    • Reddy, V.Y.1    Houghtaling, C.2    Fallon, J.3    Fischer, G.4    Farr, N.5    Clarke, J.6
  • 18
    • 27644568168 scopus 로고    scopus 로고
    • Efficacy and safety of circumferential pulmonary vein isolation using a novel cryothermal balloon ablation system
    • Sarabanda AV, Bunch TJ, Johnson SB, Mahapatra S, Milton MA, Leite LR, et al. Efficacy and safety of circumferential pulmonary vein isolation using a novel cryothermal balloon ablation system. J Am Coll Cardiol 2005; 46: 1902-1912.
    • (2005) J Am Coll Cardiol , vol.46 , pp. 1902-1912
    • Sarabanda, A.V.1    Bunch, T.J.2    Johnson, S.B.3    Mahapatra, S.4    Milton, M.A.5    Leite, L.R.6
  • 19
    • 20444472035 scopus 로고    scopus 로고
    • Freedom from atrial tachyarrhythmias after catheter ablation of atrial fibrillation: A randomized comparison between 2 current ablation strategies
    • Karch MR, Zrenner B, Deisenhofer I, Schreieck J, Ndrepepa G, Dong J, et al. Freedom from atrial tachyarrhythmias after catheter ablation of atrial fibrillation: A randomized comparison between 2 current ablation strategies. Circulation 2005; 111: 2875-2880.
    • (2005) Circulation , vol.111 , pp. 2875-2880
    • Karch, M.R.1    Zrenner, B.2    Deisenhofer, I.3    Schreieck, J.4    Ndrepepa, G.5    Dong, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.