메뉴 건너뛰기




Volumn 30, Issue 4, 2004, Pages 223-233

Finite element analysis of an osseointegrated stepped screw dental implant

Author keywords

Cylindrical screw implant; Dental implant; Finite element analysis; Stepped screw implant; Stress distribution

Indexed keywords

ARTICLE; BIOLOGICAL MODEL; BIOMECHANICS; BONE REGENERATION; COMPARATIVE STUDY; COMPUTER SIMULATION; DENTURE; ELASTICITY; FINITE ELEMENT ANALYSIS; HUMAN; IMAGE PROCESSING; MANDIBLE; MECHANICAL STRESS; PHYSIOLOGY; SURFACE PROPERTY; TOOTH IMPLANTATION; TOOTH PROSTHESIS;

EID: 6944221467     PISSN: 01606972     EISSN: 15481336     Source Type: Journal    
DOI: 10.1563/0654.1     Document Type: Article
Times cited : (48)

References (21)
  • 2
    • 0031986671 scopus 로고    scopus 로고
    • Evaluating parameters of osseointegrated dental implants using finite element analysis-A twodimensional comparative study examining the effects of implant diameter, implant shape, and load direction
    • Holmgren EP, Seckinger RJ, Kilgren LM, Mante F. Evaluating parameters of osseointegrated dental implants using finite element analysis-a twodimensional comparative study examining the effects of implant diameter, implant shape, and load direction. J Oral Implantol. 1998;24:80-88.
    • (1998) J Oral Implantol. , vol.24 , pp. 80-88
    • Holmgren, E.P.1    Seckinger, R.J.2    Kilgren, L.M.3    Mante, F.4
  • 4
    • 0030147360 scopus 로고    scopus 로고
    • Factors affecting crestal bone loss with dental implants partially covered with a porous coating: A finite element analysis
    • Vaillancount H, Pilliar RM, McCammond D. Factors affecting crestal bone loss with dental implants partially covered with a porous coating: a finite element analysis. Int J Oral Maxillofac Implants. 1996;11: 351-359.
    • (1996) Int J Oral Maxillofac Implants. , vol.11 , pp. 351-359
    • Vaillancount, H.1    Pilliar, R.M.2    McCammond, D.3
  • 5
    • 0032198792 scopus 로고    scopus 로고
    • Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog
    • Barbier L, Vander Sloten J, Krzesinski G, Schepers E, Van der Perre G. Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog. J Oral Rehabil. 1998; 25:847-858.
    • (1998) J Oral Rehabil. , vol.25 , pp. 847-858
    • Barbier, L.1    Vander Sloten, J.2    Krzesinski, G.3    Schepers, E.4    Van Der Perre, G.5
  • 6
    • 0027032178 scopus 로고
    • Load transfer from endosteal implants to supporting bone: An analysis using statics. Part one: Horizontal loading
    • Lum LB, Osier JF. Load transfer from endosteal implants to supporting bone: an analysis using statics. Part one: horizontal loading. J Oral Implantol. 1992;18: 343-348.
    • (1992) J Oral Implantol. , vol.18 , pp. 343-348
    • Lum, L.B.1    Osier, J.F.2
  • 7
    • 0026976828 scopus 로고
    • Finite element stress and strain analysis of the bone surrounding a dental implant: Effect of variations in bone modulus
    • Clift SE, Fisher J, Watson CJ. Finite element stress and strain analysis of the bone surrounding a dental implant: effect of variations in bone modulus. Proc Inst Mech Eng [H]. 1992;206: 233-241.
    • (1992) Proc Inst Mech Eng [H]. , vol.206 , pp. 233-241
    • Clift, S.E.1    Fisher, J.2    Watson, C.J.3
  • 8
    • 0031309247 scopus 로고    scopus 로고
    • Influence of bone quality on stress distribution for endosseous implants
    • Holmes DC, Loftus JT. Influence of bone quality on stress distribution for endosseous implants. J Oral Implantol. 1997;23: 104-111.
    • (1997) J Oral Implantol. , vol.23 , pp. 104-111
    • Holmes, D.C.1    Loftus, J.T.2
  • 9
    • 0030338099 scopus 로고    scopus 로고
    • Three-dimensional finite element analysis of stress-distribution around single tooth implants as a function of bony support, prosthesis type, and loading during function
    • Papavasiliou G, Kamposiora P, Bayne SC, Felton DA. Three-dimensional finite element analysis of stress-distribution around single tooth implants as a function of bony support, prosthesis type, and loading during function. J Prosthet Dent. 1996;76: 633-640.
    • (1996) J Prosthet Dent. , vol.76 , pp. 633-640
    • Papavasiliou, G.1    Kamposiora, P.2    Bayne, S.C.3    Felton, D.A.4
  • 10
    • 0035377329 scopus 로고    scopus 로고
    • Applications of finite element analysis in implant dentistry: A review of literatures
    • Geng JP, Tan KBC, Liu GR. Applications of finite element analysis in implant dentistry: a review of literatures. J Prosthet Dent. 2001;85:585-598.
    • (2001) J Prosthet Dent. , vol.85 , pp. 585-598
    • Geng, J.P.1    Kbc, T.2    Liu, G.R.3
  • 11
    • 0032229511 scopus 로고    scopus 로고
    • The influence of bone mechanical properties and implant fixation upon bone loading around oral implants
    • Van Oosterwyck H, Duyck J, Vander S, et al. The influence of bone mechanical properties and implant fixation upon bone loading around oral implants. Clin Oral Implant Res. 1998;9:407-418.
    • (1998) Clin Oral Implant Res. , vol.9 , pp. 407-418
    • Van Oosterwyck, H.1    Duyck, J.2    Vander, S.3
  • 12
    • 0024675462 scopus 로고
    • Bone resorption at the entry of osseointegrated implants-A biomechanical phenomenon. Finite element study
    • Mailath G, Stoiber B, Watzek G, Matejka M. Bone resorption at the entry of osseointegrated implants-a biomechanical phenomenon. Finite element study. Z Stomatol. 1989; 86:207-216.
    • (1989) Z Stomatol. , vol.86 , pp. 207-216
    • Mailath, G.1    Stoiber, B.2    Watzek, G.3    Matejka, M.4
  • 13
    • 0025581284 scopus 로고
    • Two-dimensional FEA analysis of hydroxyapatite implants: Diameter effects on stress distribution
    • Matsushita Y, Kitoh M, Mizuta K, Ikeda H, Suetsugu T. Two-dimensional FEA analysis of hydroxyapatite implants: diameter effects on stress distribution. J Oral Implantol. 1990;16: 6-11.
    • (1990) J Oral Implantol. , vol.16 , pp. 6-11
    • Matsushita, Y.1    Kitoh, M.2    Mizuta, K.3    Ikeda, H.4    Suetsugu, T.5
  • 14
    • 0034076530 scopus 로고    scopus 로고
    • Use of short endosseous implants and an overdenture in the extremely resorbed mandible: A five-year retrospective study
    • Stellingsma C, Meijer HJ, Raghoebar GM. Use of short endosseous implants and an overdenture in the extremely resorbed mandible: a five-year retrospective study. J Oral Maxillofac Surg. 2000;58:382-388.
    • (2000) J Oral Maxillofac Surg. , vol.58 , pp. 382-388
    • Stellingsma, C.1    Meijer, H.J.2    Raghoebar, G.M.3
  • 15
    • 0024782190 scopus 로고
    • Numerical investigations of the influence of implant shape on stress distribution in the jaw bone
    • Siegele D, Soltesz U. Numerical investigations of the influence of implant shape on stress distribution in the jaw bone. Int J Oral Maxillofac Implants. 1989;4:333-340.
    • (1989) Int J Oral Maxillofac Implants. , vol.4 , pp. 333-340
    • Siegele, D.1    Soltesz, U.2
  • 16
    • 0004207761 scopus 로고
    • Boca Raton, Fla: CRC Press;
    • Cowin SC. Bone Mechanics. Boca Raton, Fla: CRC Press; 1989.
    • (1989) Bone Mechanics
    • Cowin, S.C.1
  • 17
    • 0020173242 scopus 로고
    • A model for the implant-bone interface characteristics of porous dental implants
    • Cook SD, Klawitter JJ, Weinstein AM. A model for the implant-bone interface characteristics of porous dental implants. J Dent Res. 1982;61:1006-1009.
    • (1982) J Dent Res. , vol.61 , pp. 1006-1009
    • Cook, S.D.1    Klawitter, J.J.2    Weinstein, A.M.3
  • 18
    • 0020711801 scopus 로고
    • Three-dimensional stress distribution around a dental implant at different stages of interface development
    • Borchers L, Reichart P. Three-dimensional stress distribution around a dental implant at different stages of interface development. J Dent Res. 1983;62: 155-159.
    • (1983) J Dent Res. , vol.62 , pp. 155-159
    • Borchers, L.1    Reichart, P.2
  • 19
    • 0034487634 scopus 로고    scopus 로고
    • Finite element analysis of bone stress and strain around a distal osseointegrated implant for prosthetic limb attachment
    • Xu W, Crocombe AD, Hughes SC. Finite element analysis of bone stress and strain around a distal osseointegrated implant for prosthetic limb attachment. Proc Inst Mech Eng [H]. 2000;214: 595-602.
    • (2000) Proc Inst Mech Eng [H]. , vol.214 , pp. 595-602
    • Xu, W.1    Crocombe, A.D.2    Hughes, S.C.3
  • 21
    • 0029302999 scopus 로고
    • Nonlinear contact analysis of preload in dental implant screws
    • Ronald LS, Svenn EB. Nonlinear contact analysis of preload in dental implant screws. Int J Oral Maxillofac Implants. 1995; 10:295-302.
    • (1995) Int J Oral Maxillofac Implants. , vol.10 , pp. 295-302
    • Ronald, L.S.1    Svenn, E.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.