메뉴 건너뛰기




Volumn 235, Issue 3, 2009, Pages 273-281

A review of high-pressure freezing preparation techniques for correlative light and electron microscopy of the same cells and tissues

Author keywords

Biological EM; Correlative LM EM; Freeze substitution; High pressure freezing

Indexed keywords

ELECTRON MICROSCOPES; FREEZING; REFRIGERATORS; SPECIMEN PREPARATION;

EID: 69249144515     PISSN: 00222720     EISSN: 13652818     Source Type: Journal    
DOI: 10.1111/j.1365-2818.2009.03218.x     Document Type: Article
Times cited : (101)

References (23)
  • 3
    • 0022653966 scopus 로고
    • Advances in ultrarapid freezing for the preservation of cellular ultrastructure
    • Gilkey, J.C. Staehelin, L.A. (1986) Advances in ultrarapid freezing for the preservation of cellular ultrastructure. J. Electron Microsc. Tech. 3, 177 210.
    • (1986) J. Electron Microsc. Tech. , vol.3 , pp. 177-210
    • Gilkey, J.C.1    Staehelin, L.A.2
  • 4
    • 40649100773 scopus 로고    scopus 로고
    • Electron tomography of vitreous sections from cultured mammalian cells
    • Gruska, M., Medalia, O., Baumeister, W. Leis, A. 2008. Electron tomography of vitreous sections from cultured mammalian cells. J. Struct. Biol. 161, 384 392.
    • (2008) J. Struct. Biol. , vol.161 , pp. 384-392
    • Gruska, M.1    Medalia, O.2    Baumeister, W.3    Leis, A.4
  • 6
    • 69249126071 scopus 로고    scopus 로고
    • Freeze substitution
    • ed. by. A. Cavalier. D. Spehner& B. Humbel. pp. CRC Press. Boca Raton, Florida.
    • Humbel, B. (2009) Freeze substitution. Handbook of Cryo-Preparation Methods for Electron Microscopy (ed. by A. Cavalier, D. Spehner & B. Humbel pp. 319 341. CRC Press, Boca Raton, Florida.
    • (2009) Handbook of Cryo-Preparation Methods for Electron Microscopy , pp. 319-341
    • Humbel, B.1
  • 7
    • 69249084367 scopus 로고    scopus 로고
    • BAL-TEC HPM 010 High-pressure freezing machine
    • ed. by. A. Cavalier. D. Spehner& B. Humbel. pp. CRC Press. Boca Raton, Florida.
    • Kaech, A. (2009) BAL-TEC HPM 010 High-pressure freezing machine. Handbook of Cryo-Preparation Methods for Electron Microscopy (ed. by A. Cavalier, D. Spehner & B. Humbel pp. 101 128. CRC Press, Boca Raton, Florida.
    • (2009) Handbook of Cryo-Preparation Methods for Electron Microscopy , pp. 101-128
    • Kaech, A.1
  • 8
    • 0002724650 scopus 로고
    • The response of biological macromolecules and supramolecular structures to the physics of specimen cryopreparation
    • ed. by. R.A. Steinbrecht& K. Zierold. pp. Springer-Verlag. Berlin.
    • Kellenberger, E. (1987) The response of biological macromolecules and supramolecular structures to the physics of specimen cryopreparation. Cryotechniques in Biological Electron Microscopy (ed. by R.A. Steinbrecht & K. Zierold pp. 35 63. Springer-Verlag, Berlin.
    • (1987) Cryotechniques in Biological Electron Microscopy , pp. 35-63
    • Kellenberger, E.1
  • 10
    • 0028695433 scopus 로고
    • Electron microscopy and em immunocytochemistry. Drosophila melanogaster: Practical uses in cell and molecular biology
    • ed. by. L.S.B. Goldstein& E. Fyrberg
    • McDonald, K. (1994). Electron microscopy and EM immunocytochemistry. Drosophila melanogaster: practical uses in cell and molecular biology (ed. by L.S.B. Goldstein & E. Fyrberg Meth. Cell Biol. 44, 411 444.
    • (1994) Meth. Cell Biol. , vol.44 , pp. 411-444
    • McDonald, K.1
  • 11
    • 0032618726 scopus 로고    scopus 로고
    • High pressure freezing for preservation of high resolution fine structure and antigenicity for immunolabeling
    • McDonald, K.L. (1999) High pressure freezing for preservation of high resolution fine structure and antigenicity for immunolabeling. Methods Mol. Biol. 117, 77 97.
    • (1999) Methods Mol. Biol. , vol.117 , pp. 77-97
    • McDonald, K.L.1
  • 13
    • 0142025252 scopus 로고    scopus 로고
    • Cryoimmobilization and three-dimensional visualization of C. elegans ultrastructure
    • Müller-Reichert, T., O'Toole, E.T., Hohenberg, H. McDonald, K.L. (2003) Cryoimmobilization and three-dimensional visualization of C. elegans ultrastructure. J. Microsc. 212, 71 80.
    • (2003) J. Microsc. , vol.212 , pp. 71-80
    • Müller-Reichert, T.1    O'Toole, E.T.2    Hohenberg, H.3    McDonald, K.L.4
  • 14
    • 33847176875 scopus 로고    scopus 로고
    • Correlative light and electron microscopy of early Caenorhabditis elegans embryos in mitosis
    • Müller-Reichert, T., Srayko, M., Hyman, A.A., O'Toole, E. McDonald K. (2007) Correlative light and electron microscopy of early Caenorhabditis elegans embryos in mitosis. Meth. Cell Biol. 79, 101 119.
    • (2007) Meth. Cell Biol. , vol.79 , pp. 101-119
    • Müller-Reichert, T.1    Srayko, M.2    Hyman, A.A.3    O'Toole, E.4    McDonald, K.5
  • 16
    • 34548020973 scopus 로고    scopus 로고
    • Correlative light and electron microscopy using immunolabeled resin sections
    • Meth. Molec. Biol. 369. ed. by. J. Kuo. pp. Humana Press Inc. Totowa, New Jersey.
    • Schwarz, H. Humbel, B 2007) Correlative light and electron microscopy using immunolabeled resin sections. Electron Microscopy: Methods and Protocols, 2nd edn, Meth. Molec. Biol. 369 (ed. by J. Kuo pp. 229 256. Humana Press Inc., Totowa, New Jersey.
    • (2007) Electron Microscopy: Methods and Protocols, 2nd Edn , pp. 229-256
    • Schwarz, H.1    Humbel, B.2
  • 17
    • 69249099205 scopus 로고    scopus 로고
    • Correlative light and electron microscopy
    • ed. by. A. Cavalier. D. Spehner& B. Humbel. pp. CRC Press. Boca Raton, Florida.
    • Schwarz, H. Humbel, B. (2009) Correlative light and electron microscopy. Handbook of Cryo-Preparation Methods for Electron Microscopy (ed. by A. Cavalier, D. Spehner & B. Humbel pp. 537 565. CRC Press, Boca Raton, Florida.
    • (2009) Handbook of Cryo-Preparation Methods for Electron Microscopy , pp. 537-565
    • Schwarz, H.1    Humbel, B.2
  • 18
    • 34548472879 scopus 로고    scopus 로고
    • Cryo-fluorescence microscopy facilitates correlations between light and cryo-electron microscopy and reduces the rate of photobleaching
    • Schwartz, C., Sarbash, V.I., Ataullakhanov, F.I., McIntosh, J.R. Nicastro, D. (2007) Cryo-fluorescence microscopy facilitates correlations between light and cryo-electron microscopy and reduces the rate of photobleaching. J. Microsc. 227, 98 109.
    • (2007) J. Microsc. , vol.227 , pp. 98-109
    • Schwartz, C.1    Sarbash, V.I.2    Ataullakhanov, F.I.3    McIntosh, J.R.4    Nicastro, D.5
  • 19
    • 34548043473 scopus 로고    scopus 로고
    • Fluorescence-integrated transmission electron microscopy images
    • Meth. Molec. Biol. 369. ed. by. J. Kuo. pp. Humana Press Inc. Totowa, New Jersey.
    • Sims, P.A. Hardin, J.D. (2007) Fluorescence-integrated transmission electron microscopy images. Electron Microscopy: Methods and Protocols, 2nd edn, Meth. Molec. Biol. 369 (ed. by J. Kuo pp. 291 308. Humana Press Inc., Totowa, New Jersey.
    • (2007) Electron Microscopy: Methods and Protocols, 2nd Edn , pp. 291-308
    • Sims, P.A.1    Hardin, J.D.2
  • 20
    • 33749239641 scopus 로고    scopus 로고
    • Katanin disrupts the microtubule lattice and increases polymer number in C. elegans meiosis
    • Srayko, M., O'Toole, E.T., Hyman, A.A. Mueller-Reichert, T. (2006) Katanin disrupts the microtubule lattice and increases polymer number in C. elegans meiosis. Curr. Biol. 16, 1944 1949.
    • (2006) Curr. Biol. , vol.16 , pp. 1944-1949
    • Srayko, M.1    O'Toole, E.T.2    Hyman, A.A.3    Mueller-Reichert, T.4
  • 21
    • 0035462162 scopus 로고    scopus 로고
    • A new approach for cryofixation by high-pressure freezing
    • Studer, D., Graber, W., Al-Amoudi, A. Eggli, P. (2001) A new approach for cryofixation by high-pressure freezing. J. Microsc. Oxford 203, 285 294.
    • (2001) J. Microsc. Oxford , vol.203 , pp. 285-294
    • Studer, D.1    Graber, W.2    Al-Amoudi, A.3    Eggli, P.4
  • 22
    • 69249090017 scopus 로고    scopus 로고
    • High-pressure freezing LEICA EMPACT
    • ed. by. A. Cavalier. D. Spehner& B. Humbel. pp. CRC Press. Boca Raton, Florida.
    • Vanhecke, D., & Studer, D. (2009) High-pressure freezing LEICA EMPACT. Handbook of Cryo-Preparation Methods for Electron Microscopy (ed. by A. Cavalier, D. Spehner & B. Humbel pp. 129 156. CRC Press, Boca Raton, Florida.
    • (2009) Handbook of Cryo-Preparation Methods for Electron Microscopy , pp. 129-156
    • Vanhecke, D.1    Studer, D.2
  • 23
    • 42649111676 scopus 로고    scopus 로고
    • Moving EM: The rapid transfer system as a new tool for correlative light and electron microscopy and high throughput for high-pressure freezing
    • Verkade, P. (2008) Moving EM: the rapid transfer system as a new tool for correlative light and electron microscopy and high throughput for high-pressure freezing. J. Microsc. 230, 317 328.
    • (2008) J. Microsc. , vol.230 , pp. 317-328
    • Verkade, P.1