메뉴 건너뛰기




Volumn 95, Issue 17, 2009, Pages 1457-1463

Integrated positron emission tomography/computed tomography (PET/CT) in coronary disease

Author keywords

[No Author keywords available]

Indexed keywords

AMMONIA N 13; WATER O 15;

EID: 69249132562     PISSN: 13556037     EISSN: 1468201X     Source Type: Journal    
DOI: 10.1136/hrt.2008.151944     Document Type: Review
Times cited : (16)

References (16)
  • 1
    • 0141430974 scopus 로고    scopus 로고
    • Klocke FJ, Baird MG, Lorell BH, et al. ACC/AHA/ASNC guidelines for the clinical use of cardiac radionuclide imaging-executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASNC Committee to Revise the 1995 Guidelines for the Clinical Use of Cardiac Radionuclide Imaging). Circulation 2003;108:1404-18. ▶ American clinical guidelines for cardiac radionuclide imaging.
    • Klocke FJ, Baird MG, Lorell BH, et al. ACC/AHA/ASNC guidelines for the clinical use of cardiac radionuclide imaging-executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASNC Committee to Revise the 1995 Guidelines for the Clinical Use of Cardiac Radionuclide Imaging). Circulation 2003;108:1404-18. ▶ American clinical guidelines for cardiac radionuclide imaging.
  • 2
    • 33846240315 scopus 로고    scopus 로고
    • Diagnostic and clinical perspectives of fusion imaging in cardiology: Is the total greater than the sum of its parts?
    • Bax JJ, Beanlands RS, Klocke FJ, et al. Diagnostic and clinical perspectives of fusion imaging in cardiology: is the total greater than the sum of its parts? Heart 2007;93:16-22.
    • (2007) Heart , vol.93 , pp. 16-22
    • Bax, J.J.1    Beanlands, R.S.2    Klocke, F.J.3
  • 3
    • 0032032521 scopus 로고    scopus 로고
    • Assessment of diagnostic performance of quantitative flow measurements in normal subjects and patients with angiographically documented coronary artery disease by means of nitrogen-13 ammonia and positron emission tomography
    • This clinical study emphasises the absolute quantification of myocardial blood flow using 13N-ammonia, ▶
    • Muzik O, Duvernoy C, Beanlands RS, et al. Assessment of diagnostic performance of quantitative flow measurements in normal subjects and patients with angiographically documented coronary artery disease by means of nitrogen-13 ammonia and positron emission tomography. J Am Coll Cardiol 1998;31:534-40. ▶ This clinical study emphasises the absolute quantification of myocardial blood flow using 13N-ammonia.
    • (1998) J Am Coll Cardiol , vol.31 , pp. 534-540
    • Muzik, O.1    Duvernoy, C.2    Beanlands, R.S.3
  • 4
    • 10744221407 scopus 로고    scopus 로고
    • Yoshinaga K, Katoh C, Noriyasu K, et al. Reduction of coronary flow reserve in areas with and without ischemia on stress perfusion imaging in patients with coronary artery disease: a study using oxygen 15-labeled water PET. J Nucl Cardiol 2003;10:275-83. ▶ This clinical study emphasises the absolute quantification of myocardial blood flow using 15O-water.
    • Yoshinaga K, Katoh C, Noriyasu K, et al. Reduction of coronary flow reserve in areas with and without ischemia on stress perfusion imaging in patients with coronary artery disease: a study using oxygen 15-labeled water PET. J Nucl Cardiol 2003;10:275-83. ▶ This clinical study emphasises the absolute quantification of myocardial blood flow using 15O-water.
  • 5
    • 4344684086 scopus 로고    scopus 로고
    • Potential utility of rubidium 82 PET quantification in patients with 3-vessel coronary artery disease
    • This clinical study emphasises the absolute quantification of myocardial blood flow using 82rubidium, ▶
    • Parkash R, deKemp RA, Ruddy TD, et al. Potential utility of rubidium 82 PET quantification in patients with 3-vessel coronary artery disease. J Nucl Cardiol 2004;11:440-9. ▶ This clinical study emphasises the absolute quantification of myocardial blood flow using 82rubidium.
    • (2004) J Nucl Cardiol , vol.11 , pp. 440-449
    • Parkash, R.1    deKemp, R.A.2    Ruddy, T.D.3
  • 6
    • 69249115616 scopus 로고    scopus 로고
    • Kajander S, Ukkonen H, Joutsiniemi E, et al. The clinical value of absolute quantification of myocardial perfusion in the detection of coronary artery disease: a study using positron emission tomography to detect multi-vessel disease. Circulation 2008;118:S-1010-11. ▶ This clinical study also emphasises the absolute quantification of myocardial blood flow using 15O-water.
    • Kajander S, Ukkonen H, Joutsiniemi E, et al. The clinical value of absolute quantification of myocardial perfusion in the detection of coronary artery disease: a study using positron emission tomography to detect multi-vessel disease. Circulation 2008;118:S-1010-11. ▶ This clinical study also emphasises the absolute quantification of myocardial blood flow using 15O-water.
  • 7
    • 38349134611 scopus 로고    scopus 로고
    • Feasibility of low-dose coronary CT angiography: First experience with prospective ECG-gating
    • Husmann L, Valenta I, Gaemperli O, et al. Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating. Eur Heart J 2008;29:191-7.
    • (2008) Eur Heart J , vol.29 , pp. 191-197
    • Husmann, L.1    Valenta, I.2    Gaemperli, O.3
  • 8
    • 58149299514 scopus 로고    scopus 로고
    • Low radiation dose imaging of myocardial perfusion and coronary angiography with a hybrid PET/CT scanner
    • Kajander S, Ukkonen H, Sipilä H, et al. Low radiation dose imaging of myocardial perfusion and coronary angiography with a hybrid PET/CT scanner. Clin Physiol Funct Imaging 2009;29:81-8.
    • (2009) Clin Physiol Funct Imaging , vol.29 , pp. 81-88
    • Kajander, S.1    Ukkonen, H.2    Sipilä, H.3
  • 9
    • 34147101153 scopus 로고    scopus 로고
    • New technology for noninvasive evaluation of coronary artery disease
    • An excellent review about hybrid imaging in clinical cardiology, ▶
    • Di Carli MF, Hachamovitch R. New technology for noninvasive evaluation of coronary artery disease. Circulation 2007;115:1464- 80. ▶ An excellent review about hybrid imaging in clinical cardiology.
    • (2007) Circulation , vol.115 , pp. 1464-1480
    • Di Carli, M.F.1    Hachamovitch, R.2
  • 10
    • 57449115879 scopus 로고    scopus 로고
    • Diagnostic accuracy of 64-slice computed tomography coronary angiography: A prospective, multicenter, multivendor study
    • An important multicentre study on CT angiography, ▶
    • Meijboom WB, Meijs MF, Schuijf JD, et al. Diagnostic accuracy of 64-slice computed tomography coronary angiography: a prospective, multicenter, multivendor study. J Am Coll Cardiol 2008;52:2135-44. ▶ An important multicentre study on CT angiography.
    • (2008) J Am Coll Cardiol , vol.52 , pp. 2135-2144
    • Meijboom, W.B.1    Meijs, M.F.2    Schuijf, J.D.3
  • 11
    • 34447306296 scopus 로고    scopus 로고
    • Frequent diagnostic errors in cardiac PET/CT due to misregistration of CT attenuation and emission PET images: A definitive analysis of causes, consequences, and corrections
    • Gould KL, Pan T, Loghin C, et al. Frequent diagnostic errors in cardiac PET/CT due to misregistration of CT attenuation and emission PET images: a definitive analysis of causes, consequences, and corrections. J Nucl Med 2007;48:1112-21.
    • (2007) J Nucl Med , vol.48 , pp. 1112-1121
    • Gould, K.L.1    Pan, T.2    Loghin, C.3
  • 12
    • 23744498066 scopus 로고    scopus 로고
    • Hesse B, Tagil K, Cuocolo A, et al. EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology. Eur J Nucl Med Mol Imaging 2005;32:855-97. ▶ European procedural guidelines.
    • Hesse B, Tagil K, Cuocolo A, et al. EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology. Eur J Nucl Med Mol Imaging 2005;32:855-97. ▶ European procedural guidelines.
  • 13
    • 0142198899 scopus 로고    scopus 로고
    • Schelbert HR, Beanlands R, Bengel F, et al. PET myocardial perfusion and glucose metabolism imaging: Part 2-Guidelines for interpretation and reporting. J Nucl Cardiol 2003;10:557-71. ▶ American procedural guidelines.
    • Schelbert HR, Beanlands R, Bengel F, et al. PET myocardial perfusion and glucose metabolism imaging: Part 2-Guidelines for interpretation and reporting. J Nucl Cardiol 2003;10:557-71. ▶ American procedural guidelines.
  • 14
    • 23044484009 scopus 로고    scopus 로고
    • Integrated PET/CT for the assessment of coronary artery disease: A feasibility study
    • Namdar M, Hany TF, Koepfli P, et al. Integrated PET/CT for the assessment of coronary artery disease: a feasibility study. J Nucl Med 2005;46:930-5.
    • (2005) J Nucl Med , vol.46 , pp. 930-935
    • Namdar, M.1    Hany, T.F.2    Koepfli, P.3
  • 15
    • 33847410522 scopus 로고    scopus 로고
    • Diagnostic accuracy of rubidium-82 myocardial perfusion imaging with hybrid positron emission tomography/computed tomography in the detection of coronary artery disease
    • Sampson UK, Dorbala S, Limaye A, et al. Diagnostic accuracy of rubidium-82 myocardial perfusion imaging with hybrid positron emission tomography/computed tomography in the detection of coronary artery disease. J Am Coll Cardiol 2007;49:1052-8.
    • (2007) J Am Coll Cardiol , vol.49 , pp. 1052-1058
    • Sampson, U.K.1    Dorbala, S.2    Limaye, A.3
  • 16
    • 34247208691 scopus 로고    scopus 로고
    • Value of left ventricular ejection fraction reserve in evaluating the magnitude of myocardium at risk and the extent of angiographic coronary artery disease: A 82Rb PET/CT study
    • Dorbala S, Vangala D, Sampson U, et al. Value of left ventricular ejection fraction reserve in evaluating the magnitude of myocardium at risk and the extent of angiographic coronary artery disease: a 82Rb PET/CT study. J Nucl Med 2007;48:349-58.
    • (2007) J Nucl Med , vol.48 , pp. 349-358
    • Dorbala, S.1    Vangala, D.2    Sampson, U.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.