메뉴 건너뛰기




Volumn 33, Issue 6, 2009, Pages 1329-1337

Effect of bronchodilation on expiratory flow limitation and resting lung mechanics in COPD

Author keywords

Chronic obstructive pulmonary disease; Forced oscillation technique; Respiratory system reactance; Within breath impedance

Indexed keywords

BRONCHODILATING AGENT; LONG ACTING DRUG; SALBUTAMOL; SHORT ACTING DRUG;

EID: 69249125783     PISSN: 09031936     EISSN: 13993003     Source Type: Journal    
DOI: 10.1183/09031936.00139608     Document Type: Article
Times cited : (85)

References (41)
  • 1
    • 1842552109 scopus 로고    scopus 로고
    • Standards for the diagnosis and treatment of patients with COPD: A summary of the ATS/ERS position paper
    • Celli BR, MacNee W. Standards for the diagnosis and treatment of patients with COPD: a summary of the ATS/ERS position paper. Eur Respir J 2004; 23: 932-946.
    • (2004) Eur Respir J , vol.23 , pp. 932-946
    • Celli, B.R.1    MacNee, W.2
  • 2
    • 33846897778 scopus 로고    scopus 로고
    • Expiratory flow limitation detected by forced oscillation and negative expiratory pressure
    • Dellaca RL, Duffy N, Pompilio PP, et al. Expiratory flow limitation detected by forced oscillation and negative expiratory pressure. Eur Respir J 2007; 29: 363-374.
    • (2007) Eur Respir J , vol.29 , pp. 363-374
    • Dellaca, R.L.1    Duffy, N.2    Pompilio, P.P.3
  • 3
    • 13444269557 scopus 로고    scopus 로고
    • Flow limitation and dynamic hyperinflation: Key concepts in modern respiratory physiology
    • Calverley PM, Koulouris NG. Flow limitation and dynamic hyperinflation: key concepts in modern respiratory physiology. Eur Respir J 2005; 25: 186-199.
    • (2005) Eur Respir J , vol.25 , pp. 186-199
    • Calverley, P.M.1    Koulouris, N.G.2
  • 4
    • 0034890763 scopus 로고    scopus 로고
    • Breathing pattern and gas exchange at peak exercise in COPD patients with and without tidal flow limitation at rest
    • Diaz O, Villafranca C, Ghezzo H, et al. Breathing pattern and gas exchange at peak exercise in COPD patients with and without tidal flow limitation at rest. Eur Respir J 2001; 17: 1120-1127.
    • (2001) Eur Respir J , vol.17 , pp. 1120-1127
    • Diaz, O.1    Villafranca, C.2    Ghezzo, H.3
  • 5
    • 0036206421 scopus 로고    scopus 로고
    • Response of lung volumes to inhaled salbutamol in a large population of patients with severe hyperinflation
    • Newton MF, O'Donnell DE, Forkert L. Response of lung volumes to inhaled salbutamol in a large population of patients with severe hyperinflation. Chest 2002; 121: 1042-1050.
    • (2002) Chest , vol.121 , pp. 1042-1050
    • Newton, M.F.1    O'Donnell, D.E.2    Forkert, L.3
  • 6
    • 0041853629 scopus 로고    scopus 로고
    • Bronchodilator reversibility testing in chronic obstructive pulmonary disease
    • Calverley PM, Burge PS, Spencer S, et al. Bronchodilator reversibility testing in chronic obstructive pulmonary disease. Thorax 2003; 58: 659-664.
    • (2003) Thorax , vol.58 , pp. 659-664
    • Calverley, P.M.1    Burge, P.S.2    Spencer, S.3
  • 7
    • 21744444157 scopus 로고    scopus 로고
    • Bronchodilator response in the lung health study over 11 yrs
    • Anthonisen NR, Lindgren PG, Tashkin DP, et al. Bronchodilator response in the lung health study over 11 yrs. Eur Respir J 2005; 26: 45-51.
    • (2005) Eur Respir J , vol.26 , pp. 45-51
    • Anthonisen, N.R.1    Lindgren, P.G.2    Tashkin, D.P.3
  • 8
    • 33748848116 scopus 로고    scopus 로고
    • Effect of fluticasone propionate/salmeterol on lung hyperinflation and exercise endurance in COPD
    • O'Donnell DE, Sciurba F, Celli B, et al. Effect of fluticasone propionate/salmeterol on lung hyperinflation and exercise endurance in COPD. Chest 2006; 130: 647-656.
    • (2006) Chest , vol.130 , pp. 647-656
    • O'Donnell, D.E.1    Sciurba, F.2    Celli, B.3
  • 9
    • 0032778472 scopus 로고    scopus 로고
    • Spirometric correlates of improvement in exercise performance after anticholinergic therapy in chronic obstructive pulmonary disease
    • O'Donnell DE, Lam M, Webb KA. Spirometric correlates of improvement in exercise performance after anticholinergic therapy in chronic obstructive pulmonary disease. Am J Respir Crit Care Med 1999; 160: 542-549.
    • (1999) Am J Respir Crit Care Med , vol.160 , pp. 542-549
    • O'Donnell, D.E.1    Lam, M.2    Webb, K.A.3
  • 10
    • 0031751790 scopus 로고    scopus 로고
    • Effect of salbutamol on dynamic hyperinflation in chronic obstructive pulmonary disease patients
    • Tantucci C, Duguet A, Similowski T, et al. Effect of salbutamol on dynamic hyperinflation in chronic obstructive pulmonary disease patients. Eur Respir J 1998; 12: 799-804.
    • (1998) Eur Respir J , vol.12 , pp. 799-804
    • Tantucci, C.1    Duguet, A.2    Similowski, T.3
  • 11
    • 0036282830 scopus 로고    scopus 로고
    • Volume effect and exertional dyspnoea after bronchodilator in patients with COPD with and without expiratory flow limitation at rest
    • Boni E, Corda L, Franchini D, et al. Volume effect and exertional dyspnoea after bronchodilator in patients with COPD with and without expiratory flow limitation at rest. Thorax 2002; 57: 528-532.
    • (2002) Thorax , vol.57 , pp. 528-532
    • Boni, E.1    Corda, L.2    Franchini, D.3
  • 12
    • 0028859134 scopus 로고
    • A simple method to detect expiratory flow limitation during spontaneous breathing
    • Koulouris NG, Valta P, Lavoie A, et al. A simple method to detect expiratory flow limitation during spontaneous breathing. Eur Respir J 1995; 8: 306-313.
    • (1995) Eur Respir J , vol.8 , pp. 306-313
    • Koulouris, N.G.1    Valta, P.2    Lavoie, A.3
  • 13
    • 1042304258 scopus 로고    scopus 로고
    • Detection of expiratory flow limitation in COPD using the forced oscillation technique
    • Dellaca RL, Santus P, Aliverti A, et al. Detection of expiratory flow limitation in COPD using the forced oscillation technique. Eur Respir J 2004; 23: 232-240.
    • (2004) Eur Respir J , vol.23 , pp. 232-240
    • Dellaca, R.L.1    Santus, P.2    Aliverti, A.3
  • 14
    • 33845504072 scopus 로고    scopus 로고
    • Noninvasive detection of expiratory flow limitation in COPD patients during nasal CPAP
    • Dellacà RL, Rotger M, Aliverti A, et al. Noninvasive detection of expiratory flow limitation in COPD patients during nasal CPAP. Eur Respir J 2006; 27: 983-991.
    • (2006) Eur Respir J , vol.27 , pp. 983-991
    • Dellacà, R.L.1    Rotger, M.2    Aliverti, A.3
  • 16
    • 0032843723 scopus 로고    scopus 로고
    • Forced oscillation total respiratory resistance and spontaneous breathing lung resistance in COPD patients
    • Farre R, Peslin R, Rotger M, et al. Forced oscillation total respiratory resistance and spontaneous breathing lung resistance in COPD patients. Eur Respir J 1999; 14: 172-178.
    • (1999) Eur Respir J , vol.14 , pp. 172-178
    • Farre, R.1    Peslin, R.2    Rotger, M.3
  • 17
    • 0026787299 scopus 로고
    • Respiratory input impedance from 4 to 256 Hz in normals and chronic airflow obstruction: Comparisons and correlations with spirometry
    • Chalker RB, Celli BR, Habib RH, et al. Respiratory input impedance from 4 to 256 Hz in normals and chronic airflow obstruction: comparisons and correlations with spirometry. Am Rev Respir Dis 1992; 146: 570-576.
    • (1992) Am Rev Respir Dis , vol.146 , pp. 570-576
    • Chalker, R.B.1    Celli, B.R.2    Habib, R.H.3
  • 18
    • 34250192517 scopus 로고    scopus 로고
    • Update in chronic obstructive pulmonary disease 2006
    • Rabe KF, Beghe B, Luppi F, et al. Update in chronic obstructive pulmonary disease 2006. Am J Respir Crit Care Med 2007; 175: 1222-1232.
    • (2007) Am J Respir Crit Care Med , vol.175 , pp. 1222-1232
    • Rabe, K.F.1    Beghe, B.2    Luppi, F.3
  • 20
    • 0027515971 scopus 로고    scopus 로고
    • Quanjer PH, Tammeling GJ, Cotes JE, et al. Lung and forced ventilatory flows. Report Working Party Standardization of Lung Function Tests, European Community for Steel and Coal. Official Statement of the European Respiratory Society. Eur Respir J 1993; 6: Suppl. 16, 5-40.
    • Quanjer PH, Tammeling GJ, Cotes JE, et al. Lung volumes and forced ventilatory flows. Report Working Party Standardization of Lung Function Tests, European Community for Steel and Coal. Official Statement of the European Respiratory Society. Eur Respir J 1993; 6: Suppl. 16, 5-40.
  • 21
    • 0026947174 scopus 로고
    • Pseudorandom signals to estimate apparent transfer and coherence functions of nonlinear systems: Applications to respiratory mechanics
    • Suki B, Lutchen KR. Pseudorandom signals to estimate apparent transfer and coherence functions of nonlinear systems: applications to respiratory mechanics. IEEE Trans Biomed Eng 1992; 39: 1142-1151.
    • (1992) IEEE Trans Biomed Eng , vol.39 , pp. 1142-1151
    • Suki, B.1    Lutchen, K.R.2
  • 22
    • 0014299444 scopus 로고
    • Frequency dependence of flow resistance in patients with obstructive lung disease
    • Grimby G, Takishima T, Graham W, et al. Frequency dependence of flow resistance in patients with obstructive lung disease. J Clin Invest 1968; 47: 1455-1465.
    • (1968) J Clin Invest , vol.47 , pp. 1455-1465
    • Grimby, G.1    Takishima, T.2    Graham, W.3
  • 23
    • 0022337588 scopus 로고
    • Respiratory impedance measured with head generator to minimize upper airway shunt
    • Peslin R, Duvivier C, Didelon J, et al. Respiratory impedance measured with head generator to minimize upper airway shunt. J Appl Physiol 1985; 59: 1790-1795.
    • (1985) J Appl Physiol , vol.59 , pp. 1790-1795
    • Peslin, R.1    Duvivier, C.2    Didelon, J.3
  • 24
    • 0033126470 scopus 로고    scopus 로고
    • Technique to determine inspiratory impedance during mechanical ventilation: Implications for flow limited patients
    • Kaczka DW, Ingenito EP, Lutchen KR. Technique to determine inspiratory impedance during mechanical ventilation: implications for flow limited patients. Ann Biomed Eng 1999; 27: 340-355.
    • (1999) Ann Biomed Eng , vol.27 , pp. 340-355
    • Kaczka, D.W.1    Ingenito, E.P.2    Lutchen, K.R.3
  • 25
    • 0029256693 scopus 로고
    • Assessment of time-domain analyses for estimation of low-frequency respiratory mechanical properties and impedance spectra
    • Kaczka DW, Barnas GM, Suki B, et al. Assessment of time-domain analyses for estimation of low-frequency respiratory mechanical properties and impedance spectra. Ann Biomed Eng 1995; 23: 135-151.
    • (1995) Ann Biomed Eng , vol.23 , pp. 135-151
    • Kaczka, D.W.1    Barnas, G.M.2    Suki, B.3
  • 26
    • 0029961582 scopus 로고    scopus 로고
    • How inhomogeneities and airway walls affect frequency dependence and separation of airway and tissue properties
    • Lutchen KR, Greenstein JL, Suki B. How inhomogeneities and airway walls affect frequency dependence and separation of airway and tissue properties. J Appl Physiol 1996; 80: 1696-1707.
    • (1996) J Appl Physiol , vol.80 , pp. 1696-1707
    • Lutchen, K.R.1    Greenstein, J.L.2    Suki, B.3
  • 27
    • 24644496531 scopus 로고    scopus 로고
    • Interpretative strategies for lung functiontests
    • Pellegrino R, Viegi G, Brusasco V, et al. Interpretative strategies for lung functiontests. Eur Respir J 2005; 26: 948-968.
    • (2005) Eur Respir J , vol.26 , pp. 948-968
    • Pellegrino, R.1    Viegi, G.2    Brusasco, V.3
  • 28
    • 0018079655 scopus 로고
    • Basic principles of ROC analysis
    • Metz CE. Basic principles of ROC analysis. Semin Nucl Med 1978; 8: 283-298.
    • (1978) Semin Nucl Med , vol.8 , pp. 283-298
    • Metz, C.E.1
  • 29
    • 0034039084 scopus 로고    scopus 로고
    • Expiratory flow limitation: Roger S. Mitchell Lecture
    • Milic-Emili J. Expiratory flow limitation: Roger S. Mitchell Lecture. Chest 2000; 117: Suppl. 1, 219S-223S.
    • (2000) Chest , vol.117 , Issue.SUPPL. 1
    • Milic-Emili, J.1
  • 30
    • 77049320081 scopus 로고
    • Mechanical factors in distribution of pulmonary ventilation
    • Otis AB, Mc Kerrow CB, Bartlett RA, et al. Mechanical factors in distribution of pulmonary ventilation. J Appl Physiol 1956; 8: 427-443.
    • (1956) J Appl Physiol , vol.8 , pp. 427-443
    • Otis, A.B.1    Mc Kerrow, C.B.2    Bartlett, R.A.3
  • 31
    • 0034847496 scopus 로고    scopus 로고
    • Alternative methods for assessing bronchodilator reversibility in chronic obstructive pulmonary disease
    • Hadcroft J, Calverley PM. Alternative methods for assessing bronchodilator reversibility in chronic obstructive pulmonary disease. Thorax 2001; 56: 713-720.
    • (2001) Thorax , vol.56 , pp. 713-720
    • Hadcroft, J.1    Calverley, P.M.2
  • 32
    • 42949152368 scopus 로고    scopus 로고
    • Bronchodilator responsiveness in patients with COPD
    • Tashkin DP, Celli B, Decramer M, et al. Bronchodilator responsiveness in patients with COPD. Eur Respir J 2008; 31: 742-750.
    • (2008) Eur Respir J , vol.31 , pp. 742-750
    • Tashkin, D.P.1    Celli, B.2    Decramer, M.3
  • 33
    • 2542603339 scopus 로고    scopus 로고
    • Effects of tiotropium on lung hyperinflation, dyspnoea and exercise tolerance in COPD
    • O'Donnell DE, Fluge T, Gerken F, et al. Effects of tiotropium on lung hyperinflation, dyspnoea and exercise tolerance in COPD. Eur Respir J 2004; 23: 832-840.
    • (2004) Eur Respir J , vol.23 , pp. 832-840
    • O'Donnell, D.E.1    Fluge, T.2    Gerken, F.3
  • 34
    • 34147206088 scopus 로고    scopus 로고
    • Measurement of physiological recovery from exacerbation of chronic obstructive pulmonary disease using within-breath forced oscillometry
    • Johnson MK, Birch M, Carter R, et al. Measurement of physiological recovery from exacerbation of chronic obstructive pulmonary disease using within-breath forced oscillometry. Thorax 2007; 62: 299-306.
    • (2007) Thorax , vol.62 , pp. 299-306
    • Johnson, M.K.1    Birch, M.2    Carter, R.3
  • 35
    • 30444452071 scopus 로고    scopus 로고
    • Lung mechanics and dyspnea during exacerbations of chronic obstructive pulmonary disease
    • Stevenson NJ, Walker PP, Costello RW, et al. Lung mechanics and dyspnea during exacerbations of chronic obstructive pulmonary disease. Am J Respir Crit Care Med 2005; 172: 1510-1516.
    • (2005) Am J Respir Crit Care Med , vol.172 , pp. 1510-1516
    • Stevenson, N.J.1    Walker, P.P.2    Costello, R.W.3
  • 36
    • 3543055330 scopus 로고    scopus 로고
    • Effect of salmeterol on the ventilatory response to exercise in chronic obstructive pulmonary disease
    • O'Donnell DE, Voduc N, Fitzpatrick M, et al. Effect of salmeterol on the ventilatory response to exercise in chronic obstructive pulmonary disease. Eur Respir J 2004; 24: 86-94.
    • (2004) Eur Respir J , vol.24 , pp. 86-94
    • O'Donnell, D.E.1    Voduc, N.2    Fitzpatrick, M.3
  • 37
    • 0028146716 scopus 로고
    • Serial distribution of airway mechanical properties in dogs: Effects of histamine
    • Habib RH, Suki B, Bates JH, Jackson AC. Serial distribution of airway mechanical properties in dogs: effects of histamine. J Appl Physiol 1994; 77: 554-566.
    • (1994) J Appl Physiol , vol.77 , pp. 554-566
    • Habib, R.H.1    Suki, B.2    Bates, J.H.3    Jackson, A.C.4
  • 38
    • 0032622296 scopus 로고    scopus 로고
    • How heterogeneous bronchoconstriction affects ventilation distribution in human lungs: A morphometric model
    • Gillis HL, Lutchen KR. How heterogeneous bronchoconstriction affects ventilation distribution in human lungs: a morphometric model. Ann Biomed Eng 1999; 27: 14-22.
    • (1999) Ann Biomed Eng , vol.27 , pp. 14-22
    • Gillis, H.L.1    Lutchen, K.R.2
  • 39
    • 3042653513 scopus 로고    scopus 로고
    • Tissue heterogeneity in the mouse lung: Effects of elastase treatment
    • Ito S, Ingenito EP, Arold SP, et al. Tissue heterogeneity in the mouse lung: effects of elastase treatment. J Appl Physiol 2004; 97: 204-212.
    • (2004) J Appl Physiol , vol.97 , pp. 204-212
    • Ito, S.1    Ingenito, E.P.2    Arold, S.P.3
  • 40
    • 0027185752 scopus 로고
    • Branching airway network models for analyzing high-frequency lung input impedance
    • Jackson AC, Suki B, Ucar M, et al. Branching airway network models for analyzing high-frequency lung input impedance. J Appl Physiol 1993; 75: 217-227.
    • (1993) J Appl Physiol , vol.75 , pp. 217-227
    • Jackson, A.C.1    Suki, B.2    Ucar, M.3
  • 41
    • 38649113874 scopus 로고    scopus 로고
    • The use of plethysmography and oscillometry to compare long-acting bronchodilators in patients with COPD
    • Borrill ZL, Houghton CM, Tal-Singer R, et al. The use of plethysmography and oscillometry to compare long-acting bronchodilators in patients with COPD. Br J Clin Pharmacol 2008; 65: 244-252.
    • (2008) Br J Clin Pharmacol , vol.65 , pp. 244-252
    • Borrill, Z.L.1    Houghton, C.M.2    Tal-Singer, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.