메뉴 건너뛰기




Volumn 49, Issue 8, 2009, Pages 698-704

Computed tomography of the lungs : AA step into the fourth dimension;Computertomographie der Lunge: Ein Schritt in die Vierte Dimension

Author keywords

4D CT; Lungs; Planning CT; Respiratory gating

Indexed keywords

ALGORITHM; ARTICLE; ARTIFACT REDUCTION; BREATHING MECHANICS; BREATHING PATTERN; CANCER RADIOTHERAPY; COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC VALUE; HUMAN; IMAGE RECONSTRUCTION; LUNG TUMOR; RADIATION EXPOSURE; SPIRAL COMPUTER ASSISTED TOMOGRAPHY; TREATMENT PLANNING;

EID: 69249093869     PISSN: 0033832X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00117-009-1879-y     Document Type: Article
Times cited : (4)

References (22)
  • 1
    • 45849083882 scopus 로고    scopus 로고
    • Intrinsic respiratory gating in small-animal CT
    • Bartling SH, Dinkel J, Stiller W et al (2008) Intrinsic respiratory gating in small-animal CT. Eur Radiol 18:1375-1384
    • (2008) Eur Radiol , vol.18 , pp. 1375-1384
    • Bartling, S.H.1    Dinkel, J.2    Stiller, W.3
  • 2
    • 33845232182 scopus 로고    scopus 로고
    • Comparison of helical, maximum intensity projection (MIP) and averaged intensity (Al) 4D CT imaging for stereotactic body radiation therapy (SBRT) planning in lung cancer
    • Bradley JD, Nofal AN, EI NI et al (2006) Comparison of helical, maximum intensity projection (MIP) and averaged intensity (Al) 4D CT imaging for stereotactic body radiation therapy (SBRT) planning in lung cancer. Radiother Oncol 81:264-268
    • (2006) Radiother Oncol , vol.81 , pp. 264-268
    • Bradley, J.D.1    Nofal, A.N.2    EI, N.I.3
  • 3
    • 36349025791 scopus 로고    scopus 로고
    • Four-dimensional multislice helical CT of the lung: Qualitative comparison of retrospectively gated and static images in an ex-vivo system
    • Dinkel J, Welzel T, Boite H et al (2007) Four-dimensional multislice helical CT of the lung: qualitative comparison of retrospectively gated and static images in an ex-vivo system. Radiother Oncol 85:215-222
    • (2007) Radiother Oncol , vol.85 , pp. 215-222
    • Dinkel, J.1    Welzel, T.2    Boite, H.3
  • 4
    • 33244462026 scopus 로고    scopus 로고
    • Technical note: Gold marker implants and high-frequency jet ventilation for stereotactic, single-dose irradiation of liver tumors
    • Fritz P, Kraus HJ, Dolken W et al (2006) Technical note: gold marker implants and high-frequency jet ventilation for stereotactic, single-dose irradiation of liver tumors. Technol Cancer Res Treat 5:9-14
    • (2006) Technol Cancer Res Treat , vol.5 , pp. 9-14
    • Fritz, P.1    Kraus, H.J.2    Dolken, W.3
  • 5
    • 65749109343 scopus 로고    scopus 로고
    • Potential of image-guidance, gating and real-time tracking to improve accuracy in pulmonary stereotactic body radiotherapy
    • Guckenberger M, Krieger T, Richter A et al (2009) Potential of image-guidance, gating and real-time tracking to improve accuracy in pulmonary stereotactic body radiotherapy. Radiother Oncol 91:288295
    • (2009) Radiother Oncol , vol.91 , pp. 288295
    • Guckenberger, M.1    Krieger, T.2    Richter, A.3
  • 6
    • 0034133265 scopus 로고    scopus 로고
    • Diagnosis of tracheal instability: Spiral CT in inspiratory and expiratory and respiratory cine CT
    • Heussel CP, Hafner B, Lili J et al (2000) Diagnosis of tracheal instability: spiral CT in inspiratory and expiratory and respiratory cine CT. Rofo 172:115-121
    • (2000) Rofo , vol.172 , pp. 115-121
    • Heussel, C.P.1    Hafner, B.2    Lili, J.3
  • 7
    • 0042591561 scopus 로고    scopus 로고
    • The use of the multislice CT for the determination of respiratory lung tumor movement in stereotactic single-dose irradiation
    • Hof H, Herfarth KK, Munter M et al (2003) The use of the multislice CT for the determination of respiratory lung tumor movement in stereotactic single-dose irradiation. Strahlenther Onkol 179:542547
    • (2003) Strahlenther Onkol , vol.179 , pp. 542547
    • Hof, H.1    Herfarth, K.K.2    Munter, M.3
  • 8
    • 17844385102 scopus 로고    scopus 로고
    • Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking
    • Keall PJ, Joshi S, Vedam SS et al (2005) Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking. Med Phys 32:942-951
    • (2005) Med Phys , vol.32 , pp. 942-951
    • Keall, P.J.1    Joshi, S.2    Vedam, S.S.3
  • 9
    • 33749422038 scopus 로고    scopus 로고
    • The management of respiratory motion in radiation oncology report of AAPM Task Group 76
    • Keall PJ, Mageras GS, Balter JM et al (2006) The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Med Phys 33:3874-3900
    • (2006) Med Phys , vol.33 , pp. 3874-3900
    • Keall, P.J.1    Mageras, G.S.2    Balter, J.M.3
  • 10
    • 2942545968 scopus 로고    scopus 로고
    • Acquiring 4D thoracic CT scans using a multislice helical method
    • Keall PJ, Starkschall G, Shukla H et al (2004) Acquiring 4D thoracic CT scans using a multislice helical method. Phys Med Biol 49:2053-2067
    • (2004) Phys Med Biol , vol.49 , pp. 2053-2067
    • Keall, P.J.1    Starkschall, G.2    Shukla, H.3
  • 11
    • 44449084234 scopus 로고    scopus 로고
    • Quantification of lung volume at different tidal volumes and positive end-expiratory pressures in a porcine model by using retrospective respiratory gated 4D-computed tomography
    • Ley-Zaporozhan J, Ley S, Unterhinninghofen R et al (2008) Quantification of lung volume at different tidal volumes and positive end-expiratory pressures in a porcine model by using retrospective respiratory gated 4D-computed tomography. Invest Radiol 43:461-469
    • (2008) Invest Radiol , vol.43 , pp. 461-469
    • Ley-Zaporozhan, J.1    Ley, S.2    Unterhinninghofen, R.3
  • 12
    • 33847321630 scopus 로고    scopus 로고
    • Optimizing 4D cone-beam CT acquisition protocol for external beam radiotherapy
    • Li T, Xing L (2007) Optimizing 4D cone-beam CT acquisition protocol for external beam radiotherapy. Int J Radiat Oncol Biol Phys 67:1211-1219
    • (2007) Int J Radiat Oncol Biol Phys , vol.67 , pp. 1211-1219
    • Li, T.1    Xing, L.2
  • 13
    • 10744222972 scopus 로고    scopus 로고
    • A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing
    • Low DA, Nystrom M, Kalinin E et al (2003) A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing. Med Phys 30:1254-1263
    • (2003) Med Phys , vol.30 , pp. 1254-1263
    • Low, D.A.1    Nystrom, M.2    Kalinin, E.3
  • 14
    • 17844379268 scopus 로고    scopus 로고
    • Quantitation of the reconstruction quality of a four-dimensional computed tomography process for lung cancer patients
    • Lu W, Parikh PJ, EI NI et al (2005) Quantitation of the reconstruction quality of a four-dimensional computed tomography process for lung cancer patients. Med Phys 32:890-901
    • (2005) Med Phys , vol.32 , pp. 890-901
    • Lu, W.1    Parikh, P.J.2    EI, N.I.3
  • 15
    • 33746625978 scopus 로고    scopus 로고
    • A comparison between amplitude sorting and phase-angle sorting using external respiratory measurement for 4D CT
    • Lu W, Parikh PJ, Hubenschmidt JP et al (2006) A comparison between amplitude sorting and phase-angle sorting using external respiratory measurement for 4D CT. Med Phys 33:2964-2974
    • (2006) Med Phys , vol.33 , pp. 2964-2974
    • Lu, W.1    Parikh, P.J.2    Hubenschmidt, J.P.3
  • 16
    • 33847662456 scopus 로고    scopus 로고
    • Four-dimensional measurement of lung tumor displacement using 256-multi-slice CT-scanner
    • Mori S, Endo M, Komatsu S et al (2007) Four-dimensional measurement of lung tumor displacement using 256-multi-slice CT-scanner. Lung Cancer 56:59-67
    • (2007) Lung Cancer , vol.56 , pp. 59-67
    • Mori, S.1    Endo, M.2    Komatsu, S.3
  • 17
    • 33644947940 scopus 로고    scopus 로고
    • Linac-integrated kV-cone beam CT: Technical features and first applications
    • Oelfke U, Tucking T, Nill S et al (2006) Linac-integrated kV-cone beam CT: technical features and first applications. Med Dosim 31:62-70
    • (2006) Med Dosim , vol.31 , pp. 62-70
    • Oelfke, U.1    Tucking, T.2    Nill, S.3
  • 18
    • 0034105961 scopus 로고    scopus 로고
    • Cardiac imaging with rapid, retrospective ECG synchronized multilevel spiral CT
    • Ohnesorge B, Flohr T, Becker C et al (2000) Cardiac imaging with rapid, retrospective ECG synchronized multilevel spiral CT. Radiologe 40:111-117
    • (2000) Radiologe , vol.40 , pp. 111-117
    • Ohnesorge, B.1    Flohr, T.2    Becker, C.3
  • 19
    • 14644439819 scopus 로고    scopus 로고
    • Comparison of helical and cine acquisitions for 4D-CT imaging with multislice CT
    • Pan T (2005) Comparison of helical and cine acquisitions for 4D-CT imaging with multislice CT. Med Phys 32:627-634
    • (2005) Med Phys , vol.32 , pp. 627-634
    • Pan, T.1
  • 20
    • 21444445882 scopus 로고    scopus 로고
    • Moving targets: Detection and tracking of internal organ motion for treatment planning and patient set-up
    • Rietzel E, Rosenthal SJ, Gierga DP et al (2004) Moving targets: detection and tracking of internal organ motion for treatment planning and patient set-up. Radiother Oncol 73 [suppl 2]:S68-S72
    • (2004) Radiother Oncol , vol.73 , Issue.SUPPL. 2
    • Rietzel, E.1    Rosenthal, S.J.2    Gierga, D.P.3
  • 21
    • 0344406054 scopus 로고    scopus 로고
    • Are multiple CT scans required for planning curative radiotherapy in lung tumors of the lower lobe?
    • Van Sörnsen de Koste JR, Lagerwaard FJ, de Boer HC et al (2003) Are multiple CT scans required for planning curative radiotherapy in lung tumors of the lower lobe? Int J Radiat Oncol Biol Phys 55:1394-1399
    • (2003) Int J Radiat Oncol Biol Phys , vol.55 , pp. 1394-1399
    • Van Sörnsen de Koste, J.R.1    Lagerwaard, F.J.2    de Boer, H.C.3
  • 22
    • 50449101752 scopus 로고    scopus 로고
    • Reconstruction of a time-averaged midposition CT scan for radiotherapy planning of lung cancer patients using deformable registration
    • Wolthaus JW, Sonke JJ, Van HM et al (2008) Reconstruction of a time-averaged midposition CT scan for radiotherapy planning of lung cancer patients using deformable registration. Med Phys 35:3998-4011
    • (2008) Med Phys , vol.35 , pp. 3998-4011
    • Wolthaus, J.W.1    Sonke, J.J.2    Van, H.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.