-
1
-
-
0037112135
-
Quantitative and spatial relation of baseline atherosclerotic plaque burden and subsequent in-stent neointimal proliferation as determined by intravascular ultrasound
-
DOI 10.1016/S0002-9149(02)02791-1, PII S0002914902027911
-
Hibi K, Suzuki T, Honda Y, Hayase M, Bonneau HN, Yock PG, et al. Quantitative and spatial relation of baseline atherosclerotic plaque burden and subsequent in-stent neointimal proliferation as determined by intravascular ultrasound. Am J Cardiol 2002; 90: 1164-1167. (Pubitemid 35335614)
-
(2002)
American Journal of Cardiology
, vol.90
, Issue.10
, pp. 1164-1167
-
-
Hibi, K.1
Suzuki, T.2
Honda, Y.3
Hayase, M.4
Bonneau, H.N.5
Yock, P.G.6
Yeung, A.C.7
Fitzgerald, P.J.8
-
2
-
-
0035422744
-
Extent and distribution of in-stent intimal hyperplasia and edge effect in a non-radiation stent population
-
DOI 10.1016/S0002-9149(01)01635-6, PII S0002914901016356
-
Weissman NJ, Wilensky RL, Tanguay JF, Bartorelli AL, Moses J, Williams DO, et al. Extent and distribution of in-stent intimai hyperplasia and edge effect in a non-radiation stent population. Am J Cardiol 2001; 88: 248-252. (Pubitemid 32721950)
-
(2001)
American Journal of Cardiology
, vol.88
, Issue.3
, pp. 248-252
-
-
Weissman, N.J.1
Wilensky, R.L.2
Tanguay, J.-F.3
Bartorelli, A.L.4
Moses, J.5
Williams, D.O.6
Bailey, S.7
Martin, J.L.8
Canos, M.R.9
Rudra, H.10
Popma, J.J.11
Leon, M.B.12
Kaplan, A.V.13
Mintz, G.S.14
-
3
-
-
33751189132
-
Comparison of the Efficacy of Direct Coronary Stenting with Sirolimus-Eluting Stents Versus Stenting with Predilation by Intravascular Ultrasound Imaging (from the DIRECT Trial)
-
DOI 10.1016/j.amjcard.2006.06.046, PII S0002914906016213
-
Hirohata A, Morino Y, Ako J, Sakurai R, Buchbinder M, Caputo RP, et al. Comparison of the efficacy of direct coronary stenting with sirolimus-eluting stents versus stenting with predilation by intravascular ultrasound imaging (from the DIRECT trial). Am J Cardiol 2006; 98: 1464-1467. (Pubitemid 44779474)
-
(2006)
American Journal of Cardiology
, vol.98
, Issue.11
, pp. 1464-1467
-
-
Hirohata, A.1
Morino, Y.2
Ako, J.3
Sakurai, R.4
Buchbinder, M.5
Caputo, R.P.6
Karas, S.P.7
Mishkel, G.J.8
Mooney, M.R.9
O'Shaughnessy, C.D.10
Raizner, A.E.11
Wilensky, R.L.12
Williams, D.O.13
Wong, S.-C.14
Yock, P.G.15
Honda, Y.16
Moses, J.W.17
Fitzgerald, P.J.18
-
4
-
-
35348921846
-
Intravascular Ultrasound Findings in ENDEAVOR II and ENDEAVOR III
-
DOI 10.1016/j.amjcard.2007.08.025, PII S0002914907016669
-
Sakurai R, Bonneau HN, Honda Y, Fitzgerald PJ. Intravascular ultrasound findings in ENDEAVOR II and ENDEAVOR III. Am J Cardiol 2007; 100: 71M-76M. (Pubitemid 47576039)
-
(2007)
American Journal of Cardiology
, vol.100
, Issue.8 SUPPL. 2
-
-
Sakurai, R.1
Bonneau, H.N.2
Honda, Y.3
Fitzgerald, P.J.4
-
5
-
-
0037418032
-
Pachtaxel coating reduces in-stent intimal hyperplasia in human coronary arteries: A serial volumetric intravascular ultrasound analysis from the Asian Paclitaxel-Eluting Stent Clinical Trial (ASPECT)
-
Hong MK, Mintz GS, Lee CW, Song JM, Han KH, Kang DH, et al. Pachtaxel coating reduces in-stent intimal hyperplasia in human coronary arteries: A serial volumetric intravascular ultrasound analysis from the Asian Paclitaxel-Eluting Stent Clinical Trial (ASPECT). Circulation 2003; 107: 517-520.
-
(2003)
Circulation
, vol.107
, pp. 517-520
-
-
Hong, M.K.1
Mintz, G.S.2
Lee, C.W.3
Song, J.M.4
Han, K.H.5
Kang, D.H.6
-
6
-
-
20244376169
-
Polymer-based paclitaxel-eluting stents reduce in-stent neointimal tissue proliferation: A serial volumetric intravascular ultrasound analysis from the TAXUS-IV trial
-
DOI 10.1016/j.jacc.2004.10.078
-
Weissman NJ, Koglin J, Cox DA, Hermiller J, O'Shaughnessy C, Mann JT, et al. Polymer-based paclitaxel-eluting stents reduce in-stent neointimal tissue proliferation: A serial volumetric intravascular ultrasound analysis from the TAXUS-IV trial. J Am Coll Cardiol 2005; 45: 1201-1205. (Pubitemid 40523137)
-
(2005)
Journal of the American College of Cardiology
, vol.45
, Issue.8
, pp. 1201-1205
-
-
Weissman, N.J.1
Koglin, J.2
Cox, D.A.3
Hermiller, J.4
O'Shaughnessy, C.5
Mann, J.T.6
Turco, M.7
Caputo, R.8
Bergin, P.9
Greenberg, J.10
Kutcher, M.11
Wong, S.C.12
Strickland, W.13
Mooney, M.14
Russell, M.E.15
Ellis, S.G.16
Stone, G.W.17
-
7
-
-
34547936323
-
Detailed intravascular ultrasound analysis of Zotarolimus-eluting phosphorylcholine-coated cobalt-chromium alloy stent in de novo coronary lesions (results from the ENDEAVOR II trial)
-
Sakurai R, Hongo Y, Yamasaki M, Honda Y, Bonneau HN, Yock PG, et al. Detailed intravascular ultrasound analysis of Zotarolimus-eluting phosphorylcholine-coated cobalt-chromium alloy stent in de novo coronary lesions (results from the ENDEAVOR II trial). Am J Cardiol 2007; 100: 818-823.
-
(2007)
Am J Cardiol
, vol.100
, pp. 818-823
-
-
Sakurai, R.1
Hongo, Y.2
Yamasaki, M.3
Honda, Y.4
Bonneau, H.N.5
Yock, P.G.6
-
8
-
-
33644877576
-
Peristent remodeling and neointimal suppression 2 years after polymer-based, paclitaxel-eluting stent implantation: Insights from serial intravascular ultrasound analysis in the TAXUS II study
-
DOI 10.1161/CIRCULATIONAHA.105.558601, PII 0000301720051220000011
-
Aoki J, Colombo A, Dudek D, Banning AP, Drzewiecki J, Zmudka K, et al. Peristent remodeling and neointimal suppression 2 years after polymer-based, paclitaxel-eluting stent implantation: Insights from serial intravascular ultrasound analysis in the TAXUS II study. Circulation 2005; 112: 3876-3883. (Pubitemid 43739485)
-
(2005)
Circulation
, vol.112
, Issue.25
, pp. 3876-3883
-
-
Aoki, J.1
Colombo, A.2
Dudek, D.3
Banning, A.P.4
Drzewiecki, J.5
Zmudka, K.6
Schiele, F.7
Russell, M.E.8
Koglin, J.9
Serruys, P.W.10
-
9
-
-
0036532530
-
Intimal hyperplasia regression from 6 to 12 months after stenting
-
DOI 10.1016/S0002-9149(02)02205-1, PII S0002914902022051
-
Kuroda N, Kobayashi Y, Nameki M, Kuriyama N, Kinoshita T, Okuno T, et al. Intimai hyperplasia regression from 6 to 12 months after stenting. Am J Cardiol 2002; 89: 869-872. (Pubitemid 34241471)
-
(2002)
American Journal of Cardiology
, vol.89
, Issue.7
, pp. 869-872
-
-
Kuroda, N.1
Kobayashi, Y.2
Nameki, M.3
Kuriyama, N.4
Kinoshita, T.5
Okuno, T.6
Yamamoto, Y.7
Komiyama, N.8
Masuda, Y.9
-
10
-
-
48749090450
-
Two-year intravascular ultrasound observations in diabetic patients treated with single and double dose sirolimus-eluting stents: Results of the double dose diabetes (3D) study
-
Hur SH, Ako J, Shimada Y, Tsujino I, Hassan AH, Abizaid A, et al. Two-year intravascular ultrasound observations in diabetic patients treated with single and double dose sirolimus-eluting stents: Results of the double dose diabetes (3D) study. J Invasive Cardiol 2008; 20: 411-416.
-
(2008)
J Invasive Cardiol
, vol.20
, pp. 411-416
-
-
Hur, S.H.1
Ako, J.2
Shimada, Y.3
Tsujino, I.4
Hassan, A.H.5
Abizaid, A.6
-
11
-
-
27444446163
-
Evaluation of four-year coronary artery response after sirolimus-eluting stent implantation using serial quantitative intravascular ultrasound and computer-assisted grayscale value analysis for plaque composition in event-free patients
-
DOI 10.1016/j.jacc.2005.06.076, PII S0735109705018462
-
Aoki J, Abizaid AC, Serruys PW, Ong AT, Boersma E, Sousa JE, et al. Evaluation of four-year coronary artery response after sirolimus-eluting stent implantation using serial quantitative intravascular ultrasound and computer-assisted grayscale value analysis for plaque composition in event-free patients. J Am Coll Cardiol 2005; 46: 1670-1676. (Pubitemid 41531621)
-
(2005)
Journal of the American College of Cardiology
, vol.46
, Issue.9
, pp. 1670-1676
-
-
Aoki, J.1
Abizaid, A.C.2
Serruys, P.W.3
Ong, A.T.L.4
Boersma, E.5
Sousa, J.E.6
Bruining, N.7
-
12
-
-
0033578471
-
In vivo assessment of stent expansion and recoil in normal porcine coronary arteries: Differential outcome by stent design
-
Carrozza JP Jr, Hosley SE, Cohen DJ, Baim DS. In vivo assessment of stent expansion and recoil in normal porcine coronary arteries: Differential outcome by stent design. Circulation 1999; 100: 756-760.
-
(1999)
Circulation
, vol.100
, pp. 756-760
-
-
Carrozza Jr., J.P.1
Hosley, S.E.2
Cohen, D.J.3
Baim, D.S.4
-
13
-
-
29644444799
-
Images in cardiology: Acute recoil in sirolimus eluting stent: Real time, in vivo assessment with optical coherence tomography
-
DOI 10.1136/hrt.2005.065151
-
Regar E, Schaar J, Serruys PW. Images in cardiology: Acute recoil in sirolimus eluting stent: Real time, in vivo assessment with optical coherence tomography. Heart 2006; 92: 123. (Pubitemid 43021879)
-
(2006)
Heart
, vol.92
, Issue.1
, pp. 123
-
-
Regar, E.1
Schaar, J.2
Serruys, P.W.3
-
14
-
-
33846256643
-
Intravascular ultrasound assessment of drug-eluting stent expansion
-
DOI 10.1016/j.ahj.2006.08.026, PII S0002870306010398
-
de Ribamar Costa J Jr, Mintz GS, Carlier SG, Fujii K, Sano K, Kimura M, et al. Intravascular ultrasound assessment of drug-eluting stent expansion. Am Heart J 2007; 153: 297-303. (Pubitemid 46096874)
-
(2007)
American Heart Journal
, vol.153
, Issue.2
, pp. 297-303
-
-
De Ribamar Costa Jr., J.1
Mintz, G.S.2
Carlier, S.G.3
Fujii, K.4
Sano, K.5
Kimura, M.6
Tanaka, K.7
Costa, R.A.8
Lui, J.9
Na, Y.10
Castellanos, C.11
Biro, S.12
Moussa, I.13
Stone, G.W.14
Moses, J.W.15
Leon, M.B.16
-
15
-
-
77957875590
-
Incidence of diffuse and focal chronic stent recoil after implantation of current generation bare-metal and drug-eluting stents
-
Epub ahead of print
-
Koo BK, Waseda K, Ako J, Hasegawa T, Shimohama T, Nakatani D, et al. Incidence of diffuse and focal chronic stent recoil after implantation of current generation bare-metal and drug-eluting stents. Int J Cardiol 2009 [Epub ahead of print].
-
(2009)
Int J Cardiol
-
-
Koo, B.K.1
Waseda, K.2
Ako, J.3
Hasegawa, T.4
Shimohama, T.5
Nakatani, D.6
-
16
-
-
57449118269
-
Intravascular ultrasound analysis of small-vessel lesions treated with novel ultra-low profile, guidewire-based self-expanding stent system
-
Koo BK, Yamasaki M, Ako J, Waseda K, Honda Y, Fitzgerald PJ, et al. Intravascular ultrasound analysis of small-vessel lesions treated with novel ultra-low profile, guidewire-based self-expanding stent system. J Invasive Cardiol 2008; 20: 647-650.
-
(2008)
J Invasive Cardiol
, vol.20
, pp. 647-650
-
-
Koo, B.K.1
Yamasaki, M.2
Ako, J.3
Waseda, K.4
Honda, Y.5
Fitzgerald, P.J.6
-
17
-
-
38049004386
-
Analysis of bifurcation lesions treated with novel drug-eluting dedicated bifurcation stent system: Intravascular ultrasound results of the AXXESS PLUS trial
-
Miyazawa A, Ako J, Hassan A, Hasegawa T, Abizaid A, Verheye S, et al. Analysis of bifurcation lesions treated with novel drug-eluting dedicated bifurcation stent system: Intravascular ultrasound results of the AXXESS PLUS trial. Catheter Cardiovasc Interv 2007; 70: 952-957.
-
(2007)
Catheter Cardiovasc Interv
, vol.70
, pp. 952-957
-
-
Miyazawa, A.1
Ako, J.2
Hassan, A.3
Hasegawa, T.4
Abizaid, A.5
Verheye, S.6
-
18
-
-
60649110480
-
Analysis of left main coronary artery bifurcation lesions treated wim biolimus-eluting DEVAX AXXESS plus nitinol self-expanding stent: Intravascular ultrasound results of the AXXENT trial
-
Hasegawa T, Ako J, Koo BK, Miyazawa A, Sakurai R, Chang H, et al. Analysis of left main coronary artery bifurcation lesions treated wim biolimus-eluting DEVAX AXXESS plus nitinol self-expanding stent: Intravascular ultrasound results of the AXXENT trial. Catheter Cardiovasc Interv 2009; 73: 34-41.
-
Catheter Cardiovasc Interv 2009
, vol.73
, pp. 34-41
-
-
Hasegawa, T.1
Ako, J.2
Koo, B.K.3
Miyazawa, A.4
Sakurai, R.5
Chang, H.6
-
19
-
-
62149112196
-
9-month clinical, angiographic, and intravascular ultrasound results of a prospective evaluation of the Axxess self-expanding biolimus A9-eluting stent in coronary bifurcation lesions: The DIVERGE (Drug-Eluting Stent Intervention for Treating Side Branches Effectively) study
-
Verheye S, Agostoni P, Dubois CL, Dens J, Ormiston J, Worthley S, et al. 9-month clinical, angiographic, and intravascular ultrasound results of a prospective evaluation of the Axxess self-expanding biolimus A9-eluting stent in coronary bifurcation lesions: The DIVERGE (Drug-Eluting Stent Intervention for Treating Side Branches Effectively) study. J Am Coll Cardiol 2009; 53: 1031-1039.
-
(2009)
J Am Coll Cardiol
, vol.53
, pp. 1031-1039
-
-
Verheye, S.1
Agostoni, P.2
Dubois, C.L.3
Dens, J.4
Ormiston, J.5
Worthley, S.6
-
20
-
-
20844451557
-
Nonuniform strut distribution correlates with more neointimal hyperplasia after sirolimus-eluting stent implantation
-
DOI 10.1161/01.CIR.0000148371.53174.05
-
Takebayashi H, Mintz GS, Carlier SG, Kobayashi Y, Fujn K, Yasuda T, et al. Nonuniform strut distribution correlates with more neointimal hyperplasia after sirolimus-eluting stent implantation. Circulation 2004; 110: 3430-3434. (Pubitemid 39602221)
-
(2004)
Circulation
, vol.110
, Issue.22
, pp. 3430-3434
-
-
Takebayashi, H.1
Mintz, G.S.2
Carlier, S.G.3
Kobayashi, Y.4
Fujii, K.5
Yasuda, T.6
Costa, R.A.7
Moussa, I.8
Dangas, G.D.9
Mehran, R.10
Lansky, A.J.11
Kreps, E.12
Collins, M.B.13
Colombo, A.14
Stone, G.W.15
Leon, M.B.16
Moses, J.W.17
-
21
-
-
34347360228
-
Volumetric intravascular ultrasound assessment of neointimal hyperplasia and nonuniform stent strut distribution in sirolimus-eluting stent restenosis
-
Sano K, Mintz GS, Carlier SG, Fujii K, Takebayashi H, Kimura M, et al. Volumetric intravascular ultrasound assessment of neointimal hyperplasia and nonuniform stent strut distribution in sirolimus-eluting stent restenosis. Am J Cardiol 2006; 98: 1559-1562.
-
(2006)
Am J Cardiol
, vol.98
, pp. 1559-1562
-
-
Sano, K.1
Mintz, G.S.2
Carlier, S.G.3
Fujii, K.4
Takebayashi, H.5
Kimura, M.6
-
22
-
-
35348908304
-
Nonuniform strut distribution is associated with more neointimal hyperplasia after ABT-578 eluting stent implantation: A 3-D IVUS analysis from the ENDEAVOR 2 trial
-
Hasegawa T, Waseda K, Ako J, Sakurai R, Hongo Y, Wijns W, et al. Nonuniform strut distribution is associated with more neointimal hyperplasia after ABT-578 eluting stent implantation: A 3-D IVUS analysis from the ENDEAVOR 2 trial. J Am Coll Cardiol 2006; 47: 2B.
-
(2006)
J Am Coll Cardiol
, vol.47
-
-
Hasegawa, T.1
Waseda, K.2
Ako, J.3
Sakurai, R.4
Hongo, Y.5
Wijns, W.6
-
23
-
-
36849065425
-
Comparison of vascular response to zotarolimus-eluting stent versus sirolimus-eluting stent: Intravascular ultrasound results from ENDEAVOR III
-
DOI 10.1016/j.ahj.2007.08.008, PII S0002870307006734
-
Miyazawa A, Ako J, Hongo Y, Hur SH, Tsujino I, Courtney BK, et al. Comparison of vascular response to zotarolimus-eluting stent versus sirolimus-eluting stent: Intravascular ultrasound results from ENDEAVOR III. Am Heart J 2008; 155: 108-113. (Pubitemid 350234763)
-
(2008)
American Heart Journal
, vol.155
, Issue.1
, pp. 108-113
-
-
Miyazawa, A.1
Ako, J.2
Hongo, Y.3
Hur, S.-H.4
Tsujino, I.5
Courtney, B.K.6
Hassan, A.H.M.7
Kandzari, D.E.8
Honda, Y.9
Fitzgerald, P.J.10
-
24
-
-
69049113975
-
Neointimal hyperplasia patterns among 3 drug-eluting stents: A comparative intravascular ultrasound analysis of everolimus-, sirolimus-, and paclitaxel-eluting stents
-
Sakurai R, Courtney BK, Yamasaki M, Tsujino I, Waseda K, Hasegawa T, et al. Neointimal hyperplasia patterns among 3 drug-eluting stents: A comparative intravascular ultrasound analysis of everolimus-, sirolimus-, and paclitaxel-eluting stents. Circulation 2007; 116: 615.
-
(2007)
Circulation
, vol.116
, pp. 615
-
-
Sakurai, R.1
Courtney, B.K.2
Yamasaki, M.3
Tsujino, I.4
Waseda, K.5
Hasegawa, T.6
-
25
-
-
47349083034
-
Endothelial Cell Recovery between Comparator Polymer-Based Drug-Eluting Stents
-
DOI 10.1016/j.jacc.2008.04.030, PII S0735109708017038
-
Joner M, Nakazawa G, Finn AV, Quee SC, Coleman L, Acampado E, et al. Endothelial cell recovery between comparator polymer-based drug-eluting stents. J Am Coll Cardiol 2008; 52: 333-342. (Pubitemid 352001347)
-
(2008)
Journal of the American College of Cardiology
, vol.52
, Issue.5
, pp. 333-342
-
-
Joner, M.1
Nakazawa, G.2
Finn, A.V.3
Quee, S.C.4
Coleman, L.5
Acampado, E.6
Wilson, P.S.7
Skorija, K.8
Cheng, Q.9
Xu, X.10
Gold, H.K.11
Kolodgie, F.D.12
Virmani, R.13
-
26
-
-
34548329438
-
Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: Evaluated by optical coherence tomography
-
DOI 10.1093/eurheartj/ehl413
-
Matsumoto D, Shite J, Shinke T, Otake H, Tanino Y, Ogasawara D, et al. Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: Evaluated by optical coherence tomography. Eur Heart J 2007; 28: 961-967. (Pubitemid 47343895)
-
(2007)
European Heart Journal
, vol.28
, Issue.8
, pp. 961-967
-
-
Matsumoto, D.1
Shite, J.2
Shinke, T.3
Otake, H.4
Tanino, Y.5
Ogasawara, D.6
Sawada, T.7
Paredes, O.L.8
Hirata, K.-I.9
Yokoyama, M.10
-
27
-
-
34147135208
-
Evaluation by Optical Coherence Tomography of Neointimal Coverage of Sirolimus-Eluting Stent Three Months after Implantation
-
DOI 10.1016/j.amjcard.2006.11.068, PII S0002914907000781
-
Takano M, Inami S, Jang JK, Yamamoto M, Murakami D, Seimiya K, et al. Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation. Am J Cardiol 2007; 99: 1033-1038. (Pubitemid 46560470)
-
(2007)
American Journal of Cardiology
, vol.99
, Issue.8
, pp. 1033-1038
-
-
Takano, M.1
Inami, S.2
Jang, I.-K.3
Yamamoto, M.4
Murakami, D.5
Seimiya, K.6
Ohba, T.7
Mizuno, K.8
-
28
-
-
41649089025
-
Neointimal coverage of sirolimus-eluting stents 6 months and 12 months after implantation: Evaluation by optical coherence tomography
-
Yao ZH, Matsubara T, Inada T, Suzuki Y, Suzuki T. Neointimal coverage of sirolimus-eluting stents 6 months and 12 months after implantation: Evaluation by optical coherence tomography. Chin Med J 2008; 121: 503-507.
-
(2008)
Chin Med J
, vol.121
, pp. 503-507
-
-
Yao, Z.H.1
Matsubara, T.2
Inada, T.3
Suzuki, Y.4
Suzuki, T.5
-
29
-
-
67649867101
-
Delayed neointimalization on sirolimus-eluting stents: 6-month and 12-month follow up by optical coherence tomography
-
Katoh H, Shite J, Shinke T, Matsumoto D, Tanino Y, Ogasawara D, et al. Delayed neointimalization on sirolimus-eluting stents: 6-month and 12-month follow up by optical coherence tomography. Circ J 2009; 73: 1033-1037.
-
(2009)
Circ J
, vol.73
, pp. 1033-1037
-
-
Katoh, H.1
Shite, J.2
Shinke, T.3
Matsumoto, D.4
Tanino, Y.5
Ogasawara, D.6
-
30
-
-
47349102744
-
Comparison of Vascular Response after Sirolimus-Eluting Stent Implantation between Patients with Unstable and Stable Angina Pectoris. a Serial Optical Coherence Tomography Study
-
DOI 10.1016/j.jcmg.2008.03.012, PII S1936878X08001721
-
Kubo T, Imanishi T, Kitabata H, Kuroi A, Ueno S, Yamano T, et al. Comparison of vascular response after sirolimus-eluting stent implantation between patients with unstable and stable angina pectoris: A serial optical coherence tomography study. J Am Coll Cardiol Img 2008; 1: 475-484. (Pubitemid 351998679)
-
(2008)
JACC: Cardiovascular Imaging
, vol.1
, Issue.4
, pp. 475-484
-
-
Kubo, T.1
Imanishi, T.2
Kitabata, H.3
Kuroi, A.4
Ueno, S.5
Yamano, T.6
Tanimoto, T.7
Matsuo, Y.8
Masho, T.9
Takarada, S.10
Tanaka, A.11
Nakamura, N.12
Mizukoshi, M.13
Tomobuchi, Y.14
Akasaka, T.15
-
31
-
-
65549099770
-
A randomized optical coherence tomography study of coronary stent strut coverage and luminal protrusion with rapamycin-eluting stents
-
Moore P, Barlis P, Spiro J, Ghimire G, Roughton M, Mario CD, et al. A randomized optical coherence tomography study of coronary stent strut coverage and luminal protrusion with rapamycin-eluting stents. J Am Coll Cardiol Intv 2009; 2: 437-444.
-
(2009)
J Am Coll Cardiol Intv
, vol.2
, pp. 437-444
-
-
Moore, P.1
Barlis, P.2
Spiro, J.3
Ghimire, G.4
Roughton, M.5
Mario, C.D.6
-
32
-
-
33646252464
-
Incomplete neointimal coverage of sirolimus-eluting stents: Angioscopic findings
-
Kotani J, Awata M, Nanto S, Uematsu M, Oshima F, Minamiguchi H, et al. Incomplete neointimal coverage of sirolimus-eluting stents: Angioscopic findings. J Am Coll Cardiol 2006; 47: 2108-2111.
-
(2006)
J Am Coll Cardiol
, vol.47
, pp. 2108-2111
-
-
Kotani, J.1
Awata, M.2
Nanto, S.3
Uematsu, M.4
Oshima, F.5
Minamiguchi, H.6
-
33
-
-
33845232012
-
Angioscopic evaluation of neointima coverage: Sirolimus drug-eluting stent versus bare metal stent
-
DOI 10.1016/j.ahj.2006.07.025, PII S0002870306007411
-
Oyabu J, Ueda Y, Ogasawara N, Okada K, Hirayama A, Kodama K. Angioscopic evaluation of neointima coverage: Sirolimus drug-eluting stent versus bare metal stent. Am Heart J 2006; 152: 1168-1174. (Pubitemid 44854799)
-
(2006)
American Heart Journal
, vol.152
, Issue.6
, pp. 1168-1174
-
-
Oyabu, J.1
Ueda, Y.2
Ogasawara, N.3
Okada, K.4
Hirayama, A.5
Kodama, K.6
-
34
-
-
33748773896
-
Angioscopic differences in neointimal coverage and in persistence of thrombus between sirolimus-eluting stents and bare metal stents after a 6-month implantation
-
DOI 10.1093/eurheartj/ehl181
-
Takano M, Ohba T, Inami S, Seimiya K, Sakai S, Mizuno K. Angioscopic differences in neointimal coverage and in persistence of thrombus between sirolimus-eluting stents and bare metal stents after a 6-month implantation. Eur Heart J 2006; 27: 2189-2195. (Pubitemid 44412833)
-
(2006)
European Heart Journal
, vol.27
, Issue.18
, pp. 2189-2195
-
-
Takano, M.1
Ohba, T.2
Inami, S.3
Seimiya, K.4
Sakai, S.5
Mizuno, K.6
-
35
-
-
34548119861
-
Serial angioscopic evidence of incomplete neointimal coverage after sirolimus-eluting stent implantation: Comparison with bare-metal stents
-
DOI 10.1161/CIRCULATIONAHA.105.609057, PII 0000301720070821000008
-
Awata M, Kotani J, Uematsu M, Morozumi T, Watanabe T, Onishi T, et al. Serial angioscopic evidence of incomplete neointimal coverage after sirolimus-eluting stent implantation: comparison with bare-metal stents. Circulation 2007; 116: 910-916. (Pubitemid 47300915)
-
(2007)
Circulation
, vol.116
, Issue.8
, pp. 910-916
-
-
Awata, M.1
Kotani, J.-I.2
Uematsu, M.3
Morozumi, T.4
Watanabe, T.5
Onishi, T.6
Iida, O.7
Sera, F.8
Nanto, S.9
Hori, M.10
Nagata, S.11
-
36
-
-
36749073978
-
Serial long-term evaluation of neointimal stent coverage and thrombus after sirolimus-eluting stent implantation by use of coronary angioscopy
-
DOI 10.1136/hrt.2007.131714
-
Takano M, Yamamoto M, Xie Y, Murakami D, Inami S, Okamatsu K, et al. Serial long-term evaluation of neointimal stent coverage and thrombus after sirolimus-eluting stent implantation by use of coronary angioscopy. Heart 2007; 93: 1533-1536. (Pubitemid 350205543)
-
(2007)
Heart
, vol.93
, Issue.12
, pp. 1533-1536
-
-
Takano, M.1
Yamamoto, M.2
Xie, Y.3
Murakami, D.4
Inami, S.5
Okamatsu, K.6
Seimiya, K.7
Ohba, T.8
Seino, Y.9
Mizuno, K.10
-
37
-
-
65549117911
-
Atherosclerotic and thrombogenic neointima formed over sirolimus drug-eluting stent: An angioscopic study
-
Higo T, Ueda Y, Oyabu J, Okada K, Nishio M, Hirata A, et al. Atherosclerotic and thrombogenic neointima formed over sirolimus drug-eluting stent: An angioscopic study. J Am Coll Cardiol Img 2009; 2: 616-624.
-
(2009)
J Am Coll Cardiol Img
, vol.2
, pp. 616-624
-
-
Higo, T.1
Ueda, Y.2
Oyabu, J.3
Okada, K.4
Nishio, M.5
Hirata, A.6
-
38
-
-
65549161443
-
One step forward and two steps back with drug-eluting-stents: From preventing restenosis to causing late thrombosis and nouveau atherosclerosis
-
Nakazawa G, Vorpahl M, Finn AV, Narula J, Virmani R. One step forward and two steps back with drug-eluting-stents: From preventing restenosis to causing late thrombosis and nouveau atherosclerosis. J Am Coll Cardiol Img 2009; 2: 625-628.
-
(2009)
J Am Coll Cardiol Img
, vol.2
, pp. 625-628
-
-
Nakazawa, G.1
Vorpahl, M.2
Finn, A.V.3
Narula, J.4
Virmani, R.5
-
39
-
-
33846641777
-
Impaired endothelial vasomotor function after sirolimus-eluting stent implantation
-
DOI 10.1253/circj.71.220
-
Fuke S, Maekawa K, Kawamoto K, Saito H, Sato T, Hioka T, et al. Impaired endothelial vasomotor function after sirolimus-eluting stent implantation. Circ J 2007; 71: 220-225. (Pubitemid 46182696)
-
(2007)
Circulation Journal
, vol.71
, Issue.2
, pp. 220-225
-
-
Fuke, S.1
Maekawa, K.2
Kawamoto, K.3
Saito, H.4
Sato, T.5
Hioka, T.6
Ohe, T.7
-
40
-
-
22044436516
-
Sirolimus-eluting stents associated with paradoxic coronary vasoconstriction
-
DOI 10.1016/j.jacc.2005.01.062, PII S073510970500906X
-
Togni M, Windecker S, Cocchia R, Wenaweser P, Cook S, Billinger M, et al. Sirolimus-eluting stents associated with paradoxic coronary vasoconstriction. J Am Coll Cardiol 2005; 46: 231-236. (Pubitemid 40966848)
-
(2005)
Journal of the American College of Cardiology
, vol.46
, Issue.2
, pp. 231-236
-
-
Togni, M.1
Windecker, S.2
Cocchia, R.3
Wenaweser, P.4
Cook, S.5
Billinger, M.6
Meier, B.7
Hess, O.M.8
-
41
-
-
44049101889
-
Differential Effects of Drug-Eluting Stents on Local Endothelium- Dependent Coronary Vasomotion
-
DOI 10.1016/j.jacc.2007.12.059, PII S0735109708009662
-
Hamilos MI, Ostojic M, Beleslin B, Sagic D, Mangovski L, Stojkovic S, et al. Differential effects of drug-eluting stents on local endothelium-dependent coronary vasomotion. J Am Coll Cardiol 2008; 51: 2123-2129. (Pubitemid 351721001)
-
(2008)
Journal of the American College of Cardiology
, vol.51
, Issue.22
, pp. 2123-2129
-
-
Hamilos, M.I.1
Ostojic, M.2
Beleslin, B.3
Sagic, D.4
Mangovski, L.5
Stojkovic, S.6
Nedeljkovic, M.7
Orlic, D.8
Milosavljevic, B.9
Topic, D.10
Karanovic, N.11
Wijns, W.12
-
42
-
-
41249089935
-
Six-month comparison of coronary endothelial dysfunction associated with sirolimus-eluting stent versus Paclitaxel-eluting stent
-
Kim JW, Suh SY, Choi CU, Na JO, Kim EJ, Rha SW, et al. Six-month comparison of coronary endothelial dysfunction associated with sirolimus-eluting stent versus Paclitaxel-eluting stent. J Am Coll Cardiol Intv 2008; 1: 65-71.
-
(2008)
J Am Coll Cardiol Intv
, vol.1
, pp. 65-71
-
-
Kim, J.W.1
Suh, S.Y.2
Choi, C.U.3
Na, J.O.4
Kim, E.J.5
Rha, S.W.6
-
43
-
-
65249101325
-
A prospective, randomized, 6-month comparison of the coronary vasomotor response associated with a zotarolimus- Versus a sirolimus-eluting stent: Differential recovery of coronary endothelial dysfunction
-
Kim JW, Seo HS, Park JH, Na JO, Choi CU, Lim HE, et al. A prospective, randomized, 6-month comparison of the coronary vasomotor response associated with a zotarolimus- versus a sirolimus-eluting stent: Differential recovery of coronary endothelial dysfunction. J Am Coll Cardiol 2009; 53: 1653-1659.
-
(2009)
J Am Coll Cardiol
, vol.53
, pp. 1653-1659
-
-
Kim, J.W.1
Seo, H.S.2
Park, J.H.3
Na, J.O.4
Choi, C.U.5
Lim, H.E.6
-
44
-
-
34548819010
-
Sirolimus-Eluting Stent Implantation Aggravates Endothelial Vasomotor Dysfunction in the Infarct-Related Coronary Artery in Patients with Acute Myocardial Infarction
-
DOI 10.1016/j.jacc.2007.06.031, PII S0735109707022085
-
Obata JE, Kitta Y, Takano H, Kodama Y, Nakamura T, Mende A, et al. Sirolimus-eluting stent implantation aggravates endothelial vasomotor dysfunction in the infarct-related coronary artery in patients with acute myocardial infarction. J Am Coll Cardiol 2007; 50: 1305-1309. (Pubitemid 47446093)
-
(2007)
Journal of the American College of Cardiology
, vol.50
, Issue.14
, pp. 1305-1309
-
-
Obata, J.-E.1
Kitta, Y.2
Takano, H.3
Kodama, Y.4
Nakamura, T.5
Mende, A.6
Kawabata, K.-I.7
Saitoh, Y.8
Fujioka, D.9
Kobayashi, T.10
Yano, T.11
Kugiyama, K.12
-
45
-
-
10744233974
-
Vascular Responses at Proximal and Distal Edges of Paclitaxel-Eluting Stents: Serial Intravascular Ultrasound Analysis from the TAXUS II Trial
-
DOI 10.1161/01.CIR.0000112566.87022.32
-
Serruys PW, Degertekin M, Tanabe K, Russell ME, Guagliumi G, Webb J, et al. Vascular responses at proximal and distal edges of paclitaxel-eluting stents: Serial intravascular ultrasound analysis from the TAXUS II trial. Circulation 2004; 109: 627-633. (Pubitemid 38198870)
-
(2004)
Circulation
, vol.109
, Issue.5
, pp. 627-633
-
-
Serruys, P.W.1
Degertekin, M.2
Tanabe, K.3
Russell, M.E.4
Guagliumi, G.5
Webb, J.6
Hamburger, J.7
Rutsch, W.8
Kaiser, C.9
Whitboum, R.10
Camenzind, E.11
Meredith, I.12
Reeves, F.13
Nienaber, C.14
Benit, E.15
Disco, C.16
Koglin, J.17
Colombo, A.18
-
46
-
-
43549098749
-
Effect of lumen narrowing within sirolimus-eluting stents on proximal and distal vessel segments
-
Waseda K, Ako J, Kaneda H, Miyazawa A, Shimada Y, Morino Y, et al. Effect of lumen narrowing within sirolimus-eluting stents on proximal and distal vessel segments. Circ J 2008; 72: 534-537.
-
(2008)
Circ J
, vol.72
, pp. 534-537
-
-
Waseda, K.1
Ako, J.2
Kaneda, H.3
Miyazawa, A.4
Shimada, Y.5
Morino, Y.6
-
47
-
-
23044450877
-
Effect of lumen narrowing within coronary stents on proximal and distal vessel segments following bare metal stent implantation
-
DOI 10.1016/j.amjcard.2005.03.079, PII S0002914905007356
-
Kaneda H, Ako J, Kataoka T, Miyazawa A, Terashima M, Ikeno F, et al. Effect of lumen narrowing within coronary stents on proximal and distal vessel segments following bare metal stent implantation. Am J Cardiol 2005; 96: 376-378. (Pubitemid 41058862)
-
(2005)
American Journal of Cardiology
, vol.96
, Issue.3
, pp. 376-378
-
-
Kaneda, H.1
Ako, J.2
Kataoka, T.3
Miyazawa, A.4
Terashima, M.5
Ikeno, F.6
Sonoda, S.7
Shimada, Y.8
Morino, Y.9
Honda, Y.10
Yock, P.G.11
Fitzgerald, P.J.12
-
48
-
-
9144238090
-
Chronic Arterial Responses to Polymer-Controlled Paclitaxel-Eluting Stents: Comparison with Bare Metal Stents by Serial Intravascular Ultrasound Analyses: Data from the Randomized TAXUS-II Trial
-
DOI 10.1161/01.CIR.0000109137.51122.49
-
Tanabe K, Serruys PW, Degertekin M, Guagliumi G, Grube E, Chan C, et al. Chronic arterial responses to polymer-controlled paclitaxel-eluting stents: Comparison with bare metal stents by serial intravascular ultrasound analyses: Data from the randomized TAXUS-II trial. Circulation 2004; 109: 196-200. (Pubitemid 38114139)
-
(2004)
Circulation
, vol.109
, Issue.2
, pp. 196-200
-
-
Tanabe, K.1
Serruys, P.W.2
Degertekin, M.3
Guagliumi, G.4
Grube, E.5
Chan, C.6
Munzel, T.7
Belardi, J.8
Ruzyllo, W.9
Bilodeau, L.10
Kelbaek, H.11
Ormiston, J.12
Dawkins, K.13
Roy, L.14
Strauss, B.H.15
Disco, C.16
Koglin, J.17
Russell, M.E.18
Colombo, A.19
-
49
-
-
68749089815
-
Comparison of vascular response between zotarolimus-eluting stent and paclitaxel-eluting stent implantation: IVUS results from the ENDEAVOR IV trial
-
in press
-
Waseda K, Miyazawa A, Ako J, Hasegawa T, Tsujino I, Sakurai R, et al. Comparison of vascular response between zotarolimus-eluting stent and paclitaxel-eluting stent implantation: IVUS results from the ENDEAVOR IV trial. JAm Coll Cardiol Intv 2009 (in press).
-
(2009)
JAm Coll Cardiol Intv
-
-
Waseda, K.1
Miyazawa, A.2
Ako, J.3
Hasegawa, T.4
Tsujino, I.5
Sakurai, R.6
-
50
-
-
35348913254
-
The Significance of Preclinical Evaluation of Sirolimus-, Paclitaxel-, and Zotarolimus-Eluting Stents
-
DOI 10.1016/j.amjcard.2007.08.020, PII S000291490701658X
-
Nakazawa G, Finn AV, John MC, Kolodgie FD, Virmani R. The significance of preclinical evaluation of sirolimus-, paclitaxel-, and zotarolimus-eluting stents. Am J Cardiol 2007; 100: 36M-44M. (Pubitemid 47576035)
-
(2007)
American Journal of Cardiology
, vol.100
, Issue.8 SUPPL. 2
-
-
Nakazawa, G.1
Finn, A.V.2
John, M.C.3
Kolodgie, F.D.4
Virmani, R.5
-
52
-
-
64849091370
-
The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography
-
Tanigawa J, Barlis P, Dimopoulos K, Dalby M, Moore P, Di Mario C. The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography. Int J Cardiol 2009; 134: 180-188.
-
(2009)
Int J Cardiol
, vol.134
, pp. 180-188
-
-
Tanigawa, J.1
Barlis, P.2
Dimopoulos, K.3
Dalby, M.4
Moore, P.5
Di Mario, C.6
-
53
-
-
77952378647
-
Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis
-
Epub ahead of print
-
Hassan AK, Bergheanu SC, Stijnen T, van der Hoeven BL, Snoep JD, Plevier JW, et al. Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis. Eur Heart J 2009 [Epub ahead of print].
-
(2009)
Eur Heart J
-
-
Hassan, A.K.1
Bergheanu, S.C.2
Stijnen, T.3
Van Der Hoeven, B.L.4
Snoep, J.D.5
Plevier, J.W.6
-
54
-
-
24944585578
-
Late incomplete stent apposition after sirolimus-eluting stent implantation: A serial intravascular ultrasound analysis
-
DOI 10.1016/j.jacc.2005.05.068, PII S0735109705013975
-
Ako J, Morino Y, Honda Y, Hassan A, Sonoda S, Yock PG, et al. Late incomplete stent apposition after sirolimus-eluting stent implantation: A serial intravascular ultrasound analysis. J Am Coll Cardiol 2005; 46: 1002-1005. (Pubitemid 41316506)
-
(2005)
Journal of the American College of Cardiology
, vol.46
, Issue.6
, pp. 1002-1005
-
-
Ako, J.1
Morino, Y.2
Honda, Y.3
Hassan, A.4
Sonoda, S.5
Yock, P.G.6
Leon, M.B.7
Moses, J.W.8
Bonneau, H.N.9
Fitzgerald, P.J.10
-
55
-
-
61349095368
-
Classification and potential mechanisms of intravascular ultrasound patterns of stent fracture
-
Doi H, Maehara A, Mintz GS, Tsujita K, Kubo T, Castellanos C, et al. Classification and potential mechanisms of intravascular ultrasound patterns of stent fracture. Am J Cardiol 2009; 103: 818-823.
-
(2009)
Am J Cardiol
, vol.103
, pp. 818-823
-
-
Doi, H.1
Maehara, A.2
Mintz, G.S.3
Tsujita, K.4
Kubo, T.5
Castellanos, C.6
-
56
-
-
33745697915
-
Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation
-
Hong MK, Mintz GS, Lee CW, Park DW, Choi BR, Park KH, et al. Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation. Eur Heart J 2006; 27: 1305-1310.
-
(2006)
Eur Heart J
, vol.27
, pp. 1305-1310
-
-
Hong, M.K.1
Mintz, G.S.2
Lee, C.W.3
Park, D.W.4
Choi, B.R.5
Park, K.H.6
-
57
-
-
12144286893
-
Contribution of Stent Underexpansion to Recurrence after Sirolimus-Eluting Stent Implantation for In-Stent Restenosis
-
DOI 10.1161/01.CIR.0000121327.67756.19
-
Fujii K, Mintz GS, Kobayashi Y, Carlier SG, Takebayashi H, Yasuda T, et al. Contribution of stent underexpansion to recurrence after sirolimus-eluting stent implantation for in-stent restenosis. Circulation 2004; 109: 1085-1088. (Pubitemid 38332610)
-
(2004)
Circulation
, vol.109
, Issue.9
, pp. 1085-1088
-
-
Fujii, K.1
Mintz, G.S.2
Kobayashi, Y.3
Carlier, S.G.4
Takebayashi, H.5
Yasuda, T.6
Moussa, I.7
Dangas, G.8
Mehran, R.9
Lansky, A.J.10
Reyes, A.11
Kreps, E.12
Collins, M.13
Colombo, A.14
Stone, G.W.15
Teirstein, P.S.16
Leon, M.B.17
Moses, J.W.18
-
58
-
-
2542445152
-
Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: Serial intravascular ultrasound analysis from the SIRIUS trial
-
DOI 10.1016/j.jacc.2004.01.044, PII S0735109704005807
-
Sonoda S, Morino Y, Ako J, Terashima M, Hassan AH, Bonneau HN, et al. Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: Serial intravascular ultrasound analysis from the sirius trial. J Am Coll Cardiol 2004; 43: 1959-1963. (Pubitemid 38686788)
-
(2004)
Journal of the American College of Cardiology
, vol.43
, Issue.11
, pp. 1959-1963
-
-
Sonoda, S.1
Morino, Y.2
Ako, J.3
Terashima, M.4
Hassan, A.H.M.5
Bonneau, H.N.6
Leon, M.B.7
Moses, J.W.8
Yock, P.G.9
Honda, Y.10
Kuntz, R.E.11
Fitzgerald, P.J.12
-
59
-
-
36048962064
-
Intravascular Ultrasound Findings during Episodes of Drug-Eluting Stent Thrombosis
-
DOI 10.1016/j.jacc.2007.08.015, PII S0735109707027131
-
Alfonso F, Suarez A, Perez-Vizcayno MJ, Moreno R, Escaned J, Banuelos C, et al. Intravascular ultrasound findings during episodes of drug-eluting stent thrombosis. J Am Coll Cardiol 2007; 50: 2095-2097. (Pubitemid 350087569)
-
(2007)
Journal of the American College of Cardiology
, vol.50
, Issue.21
, pp. 2095-2097
-
-
Alfonso, F.1
Suarez, A.2
Perez-Vizcayno, M.J.3
Moreno, R.4
Escaned, J.5
Banuelos, C.6
Jimenez, P.7
Bernardo, E.8
Angiolillo, D.J.9
Hernandez, R.10
Macaya, C.11
-
60
-
-
20144388922
-
Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: An intravascular ultrasound study
-
DOI 10.1016/j.jacc.2004.12.066
-
Fujii K, Carlier SG, Mintz GS, Yang YM, Moussa I, Weisz G, et al. Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: An intravascular ultrasound study. J Am Coll Cardiol 2005; 45: 995-998. (Pubitemid 40432428)
-
(2005)
Journal of the American College of Cardiology
, vol.45
, Issue.7
, pp. 995-998
-
-
Fujii, K.1
Carlier, S.G.2
Mintz, G.S.3
Yang, Y.-M.4
Moussa, I.5
Weisz, G.6
Dangas, G.7
Mehran, R.8
Lansky, A.J.9
Kreps, E.M.10
Collins, M.11
Stone, G.W.12
Moses, J.W.13
Leon, M.B.14
-
61
-
-
34547657959
-
Intravascular Ultrasound Parameters Associated with Stent Thrombosis after Drug-Eluting Stent Deployment
-
DOI 10.1016/j.amjcard.2007.03.072, PII S0002914907009058
-
Okabe T, Mintz GS, Buch AN, Roy P, Hong YJ, Smith KA, et al. Intravascular ultrasound parameters associated with stent thrombosis after drug-eluting stent deployment. Am J Cardiol 2007; 100: 615-620. (Pubitemid 47223136)
-
(2007)
American Journal of Cardiology
, vol.100
, Issue.4
, pp. 615-620
-
-
Okabe, T.1
Mintz, G.S.2
Buch, A.N.3
Roy, P.4
Hong, Y.J.5
Smith, K.A.6
Torguson, R.7
Gevorkian, N.8
Xue, Z.9
Satler, L.F.10
Kent, K.M.11
Pichard, A.D.12
Weissman, N.J.13
Waksman, R.14
-
62
-
-
27144521420
-
Predictors of edge stenosis following sirolimus-eluting stent deployment (A quantitative intravascular ultrasound analysis from the SIRIUS trial)
-
DOI 10.1016/j.amjcard.2005.06.066, PII S0002914905012658
-
Sakurai R, Ako J, Morino Y, Sonoda S, Kaneda H, Terashima M, et al. Predictors of edge stenosis following sirolimus-eluting stent deployment (a quantitative intravascular ultrasound analysis from the SIRIUS trial). Am J Cardiol 2005; 96: 1251-1253. (Pubitemid 41505403)
-
(2005)
American Journal of Cardiology
, vol.96
, Issue.9
, pp. 1251-1253
-
-
Sakurai, R.1
Ako, J.2
Morino, Y.3
Sonoda, S.4
Kaneda, H.5
Terashima, M.6
Hassan, A.H.M.7
Leon, M.B.8
Moses, J.W.9
Popma, J.J.10
Bonneau, H.N.11
Yock, P.G.12
Fitzgerald, P.J.13
Honda, Y.14
-
63
-
-
44749083836
-
Impact of stent deployment procedural factors on long-term effectiveness and safety of sirolimus-eluting stents (final results of the multicenter prospective STLLR trial)
-
Costa MA, Angiolillo DJ, Tannenbaum M, Driesman M, Chu A, Patterson J, et al. Impact of stent deployment procedural factors on long-term effectiveness and safety of sirolimus-eluting stents (final results of the multicenter prospective STLLR trial). Am J Cardiol 2008; 101: 1704-1711.
-
(2008)
Am J Cardiol
, vol.101
, pp. 1704-1711
-
-
Costa, M.A.1
Angiolillo, D.J.2
Tannenbaum, M.3
Driesman, M.4
Chu, A.5
Patterson, J.6
-
64
-
-
0037417844
-
TAXUS III trial: In-stent restenosis treated with stent-based delivery of paclitaxel incorporated in a slow-release polymer formulation
-
DOI 10.1161/01.CIR.0000048184.96491.8A
-
Tanabe K, Serruys PW, Grube E, Smits PC, Selbach G, van der Giessen WJ, et al. TAXUS III Trial: In-stent restenosis treated with stent-based delivery of paclitaxel incorporated in a slow-release polymer formulation. Circulation 2003; 107: 559-564. (Pubitemid 36176804)
-
(2003)
Circulation
, vol.107
, Issue.4
, pp. 559-564
-
-
Tanabe, K.1
Serruys, P.W.2
Grube, E.3
Smits, P.C.4
Selbach, G.5
Van Der Giessen, W.J.6
Staberock, M.7
De Feyter, P.8
Muller, R.9
Regar, E.10
Degertekin, M.11
Ligthart, J.M.R.12
Disco, C.13
Backx, B.14
Russell, M.E.15
-
65
-
-
34447574772
-
Neointimal progression and luminal narrowing in sirolimus-eluting stent treatment for bare metal in-stent restenosis: A quantitative intravascular ultrasound analysis
-
DOI 10.1016/j.ahj.2007.04.023, PII S0002870307003444
-
Sakurai R, Ako J, Hassan AH, Bonneau HN, Neumann FJ, Desmet W, et al. Neointimal progression and luminal narrowing in sirolimus-eluting stent treatment for bare metal in-stent restenosis: A quantitative intravascular ultrasound analysis. Am Heart J 2007; 154: 361-365. (Pubitemid 47069132)
-
(2007)
American Heart Journal
, vol.154
, Issue.2
, pp. 361-365
-
-
Sakurai, R.1
Ako, J.2
Hassan, A.H.M.3
Bonneau, H.N.4
Neumann, F.-J.5
Desmet, W.6
Holmes Jr., D.R.7
Yock, P.G.8
Fitzgerald, P.J.9
Honda, Y.10
-
66
-
-
48749095178
-
The potential clinical utility of intravascular ultrasound guidance in patients undergoing percutaneous coronary intervention with drug-eluting stents
-
Roy P, Steinberg DH, Sushinsky SJ, Okabe T, Pinto Slottow TL, Kaneshige K, et al. The potential clinical utility of intravascular ultrasound guidance in patients undergoing percutaneous coronary intervention with drug-eluting stents. Eur Heart J 2008; 29: 1851-1857.
-
(2008)
Eur Heart J
, vol.29
, pp. 1851-1857
-
-
Roy, P.1
Steinberg, D.H.2
Sushinsky, S.J.3
Okabe, T.4
Pinto Slottow, T.L.5
Kaneshige, K.6
-
67
-
-
69049095006
-
Impact of intravascular ultrasound guidance on long-term mortality in stenting for unprotected left main coronary artery stenosis
-
E-pub ahead of print
-
Park SJ, Kim YH, Park DW, Lee SW, Kim WJ, Suh J, et al. Impact of intravascular ultrasound guidance on long-term mortality in stenting for unprotected left main coronary artery stenosis. Circ Cardiovasc Intervent 2009 [E-pub ahead of print].
-
(2009)
Circ Cardiovasc Intervent
-
-
Park, S.J.1
Kim, Y.H.2
Park, D.W.3
Lee, S.W.4
Kim, W.J.5
Suh, J.6
|