-
1
-
-
0343698399
-
Hydrogel intervertebral disc nucleus
-
US Patent 5,047,055
-
Bao, Q., Higham, P., 1991. Hydrogel intervertebral disc nucleus. US Patent 5,047,055
-
(1991)
-
-
Bao, Q.1
Higham, P.2
-
3
-
-
0035869825
-
The effects of scaffold thickness on tissue engineered cartilage in photocrosslinked poly(ethylene oxide) hydrogels
-
Bryant S., and Anseth K. The effects of scaffold thickness on tissue engineered cartilage in photocrosslinked poly(ethylene oxide) hydrogels. Biomaterials 22 (2001) 619-626
-
(2001)
Biomaterials
, vol.22
, pp. 619-626
-
-
Bryant, S.1
Anseth, K.2
-
5
-
-
0006109857
-
Formation of hydrogel of polyacrylamide in solution by gamma irradiation
-
Burillo G., and Ogawa T. Formation of hydrogel of polyacrylamide in solution by gamma irradiation. Makromol. Chem., Rapid Commun. 1 (1980) 545-550
-
(1980)
Makromol. Chem., Rapid Commun.
, vol.1
, pp. 545-550
-
-
Burillo, G.1
Ogawa, T.2
-
6
-
-
0020888598
-
Surface tension of animal cartilage as it relates to friction in joints
-
Chappuis J., Sherman I.A., and Neumann A.W. Surface tension of animal cartilage as it relates to friction in joints. Ann. Biomed. Eng. II (1983) 435-449
-
(1983)
Ann. Biomed. Eng.
, vol.II
, pp. 435-449
-
-
Chappuis, J.1
Sherman, I.A.2
Neumann, A.W.3
-
7
-
-
0032605335
-
The influence of continuous sliding and subsequent surface wear on the friction of articular cartilage
-
Forster H., and Fisher J. The influence of continuous sliding and subsequent surface wear on the friction of articular cartilage. Proc. Inst. Mech. Eng. H4 (1999) 329-345
-
(1999)
Proc. Inst. Mech. Eng.
, Issue.H4
, pp. 329-345
-
-
Forster, H.1
Fisher, J.2
-
8
-
-
0033497937
-
The mechanical-chemical attachment between the artificial cartilage (PVA-hydrogel) and metal substrate (or underlying bone)
-
Gu Z., Xio J., and Lou S. The mechanical-chemical attachment between the artificial cartilage (PVA-hydrogel) and metal substrate (or underlying bone). Biomed. Mater. Eng. 9 (1999) 347-351
-
(1999)
Biomed. Mater. Eng.
, vol.9
, pp. 347-351
-
-
Gu, Z.1
Xio, J.2
Lou, S.3
-
9
-
-
0033854001
-
Articular cartilage biomechanics: Theoretical models, material properties, and biosynthetic response
-
Hasler E.M., Herzog W., and Wu J.Z. Articular cartilage biomechanics: Theoretical models, material properties, and biosynthetic response. Crit. Rev. Biomed. Eng. 27 6 (1999) 415-488
-
(1999)
Crit. Rev. Biomed. Eng.
, vol.27
, Issue.6
, pp. 415-488
-
-
Hasler, E.M.1
Herzog, W.2
Wu, J.Z.3
-
10
-
-
0034448636
-
-
Springer, Berlin, Heidelberg
-
Hassan C.M., and Peppas N.A. Structure and Applications of Poly(vinyl alcohol) Hydrogels Produced by Conventional Crosslinking or by Freezing/Thawing Methods. Adv. in Poly. Sci. vol. 153 (2000), Springer, Berlin, Heidelberg 37-65
-
(2000)
Adv. in Poly. Sci.
, vol.153
, pp. 37-65
-
-
Hassan, C.M.1
Peppas, N.A.2
-
11
-
-
0031901185
-
Deficiency of lubricating surfactant lining the articular surfaces of replaced hips and knees
-
Hills B.A., and Monds M.K. Deficiency of lubricating surfactant lining the articular surfaces of replaced hips and knees. Br. J. Rheumatol. 37 (1998) 143-147
-
(1998)
Br. J. Rheumatol.
, vol.37
, pp. 143-147
-
-
Hills, B.A.1
Monds, M.K.2
-
12
-
-
84971761901
-
Environmentally sensitive polymers and hydrogels: 'Smart' biomaterials
-
Hoffman A. Environmentally sensitive polymers and hydrogels: 'Smart' biomaterials. MRS Bull. September (1991) 42-46
-
(1991)
MRS Bull.
, Issue.September
, pp. 42-46
-
-
Hoffman, A.1
-
13
-
-
33747620101
-
Polymers for tissue engineering, medical devices, and regenerative medicine. Concise general review of recent studies
-
Jagur-Grodzinski J. Polymers for tissue engineering, medical devices, and regenerative medicine. Concise general review of recent studies. Polym. Adv. Technol. 23 (2006) 395-418
-
(2006)
Polym. Adv. Technol.
, vol.23
, pp. 395-418
-
-
Jagur-Grodzinski, J.1
-
14
-
-
34250623695
-
Effect of load variation on the friction properties of articular cartilage
-
May
-
Katta J., Pawaskar S.S., and Jin Z.M. Effect of load variation on the friction properties of articular cartilage. Proc. Inst. Mech. Eng. 221 J3 (2007) 175-181 May
-
(2007)
Proc. Inst. Mech. Eng.
, vol.221
, Issue.J3
, pp. 175-181
-
-
Katta, J.1
Pawaskar, S.S.2
Jin, Z.M.3
-
15
-
-
0037340849
-
Development of an artificial meniscus using polyvinyl alcohol-hydrogel for early return to, and continuance of, athletic life in sportspersons with severe meniscus injury II
-
Kobayashi M., Toguchida J., and Oka M. Development of an artificial meniscus using polyvinyl alcohol-hydrogel for early return to, and continuance of, athletic life in sportspersons with severe meniscus injury II. Animal experiments. Knee. 10 (2003) 53
-
(2003)
Animal experiments. Knee.
, vol.10
, pp. 53
-
-
Kobayashi, M.1
Toguchida, J.2
Oka, M.3
-
16
-
-
0037290220
-
Preliminary study of polyvinyl alcohol-hydrogel (PVA-H) artificial meniscus
-
Kobayashi M., Toguchida J., and Oka M. Preliminary study of polyvinyl alcohol-hydrogel (PVA-H) artificial meniscus. Biomaterials 24 (2003) 639-647
-
(2003)
Biomaterials
, vol.24
, pp. 639-647
-
-
Kobayashi, M.1
Toguchida, J.2
Oka, M.3
-
17
-
-
0036276704
-
Comparison of the equilibrium response of articular cartilage in unconfined compression, confined compression and indentation
-
July
-
Korhonen R.K., Laasanen M.S., and Toyras J. Comparison of the equilibrium response of articular cartilage in unconfined compression, confined compression and indentation. J. Biomech. 35 7 (2002) 903-909 July
-
(2002)
J. Biomech.
, vol.35
, Issue.7
, pp. 903-909
-
-
Korhonen, R.K.1
Laasanen, M.S.2
Toyras, J.3
-
18
-
-
0042423474
-
Physical properties of hydrogels synthesized from lyotropic liquid crystalline templates
-
Lester C., Smith S., and Colson C. Physical properties of hydrogels synthesized from lyotropic liquid crystalline templates. Chem. Mater. 15 (2003) 3376-3384
-
(2003)
Chem. Mater.
, vol.15
, pp. 3376-3384
-
-
Lester, C.1
Smith, S.2
Colson, C.3
-
19
-
-
40949122428
-
Preparation and mechanical characterization of a PNIPA hydrogel composite
-
Liu K., Ovaert T.C., and Mason J.J. Preparation and mechanical characterization of a PNIPA hydrogel composite. J. Mat. Sci.: Mat. in Med. 19 4 (2008) 1815-1821
-
(2008)
J. Mat. Sci.: Mat. in Med.
, vol.19
, Issue.4
, pp. 1815-1821
-
-
Liu, K.1
Ovaert, T.C.2
Mason, J.J.3
-
20
-
-
40949125977
-
Meniscus-type implant with hydrogel surface reinforced by three-dimensional mesh
-
US Patent 6,629,997
-
Mansmann, K.A., 2003. Meniscus-type implant with hydrogel surface reinforced by three-dimensional mesh. US Patent 6,629,997
-
(2003)
-
-
Mansmann, K.A.1
-
21
-
-
0027688078
-
Biomechanics of diathroidal joints - A review of 20 years of progress
-
Part B
-
Mow V.C., Ateshian G.A., and Spilker R.L. Biomechanics of diathroidal joints - A review of 20 years of progress. J. Biomech. Eng. Trans. ASME 115 4 (1993) 460-467 Part B
-
(1993)
J. Biomech. Eng. Trans. ASME
, vol.115
, Issue.4
, pp. 460-467
-
-
Mow, V.C.1
Ateshian, G.A.2
Spilker, R.L.3
-
23
-
-
0033631534
-
Development of artificial articular cartilage
-
Oka M., Ushio K., Kumar P., Ikeuchi K., Hyon S.H., Nakamura T., and Fujita H. Development of artificial articular cartilage. Proc. Inst. Mech. Eng. 214 (2000) 59-68
-
(2000)
Proc. Inst. Mech. Eng.
, vol.214
, pp. 59-68
-
-
Oka, M.1
Ushio, K.2
Kumar, P.3
Ikeuchi, K.4
Hyon, S.H.5
Nakamura, T.6
Fujita, H.7
-
24
-
-
0345863385
-
Animal models for cartilage reconstruction
-
Reinholz G., Lu L., Saris D., Yaszemski M., and O'Driscoll S. Animal models for cartilage reconstruction. Biomaterials 25 (2004) 1511-1521
-
(2004)
Biomaterials
, vol.25
, pp. 1511-1521
-
-
Reinholz, G.1
Lu, L.2
Saris, D.3
Yaszemski, M.4
O'Driscoll, S.5
-
25
-
-
68949220417
-
Blend hydrogels and methods of making
-
US Patent Application 20060188487, August 24
-
Thomas, B., Yakimicki, D., Hudgins, R., 2006. Blend hydrogels and methods of making. US Patent Application 20060188487, August 24
-
(2006)
-
-
Thomas, B.1
Yakimicki, D.2
Hudgins, R.3
-
26
-
-
68949215893
-
Prosthetic replacement of the medial meniscus in cadaver knees
-
Tienen T.G., Verdonschot N., Heijkants R., Buma P., Scholten J., Van Kampen A., and Verth R. Prosthetic replacement of the medial meniscus in cadaver knees. ASJM Preview 18 May (2004)
-
(2004)
ASJM Preview
, vol.18
, Issue.May
-
-
Tienen, T.G.1
Verdonschot, N.2
Heijkants, R.3
Buma, P.4
Scholten, J.5
Van Kampen, A.6
Verth, R.7
-
27
-
-
0347986706
-
Attachment of artificial cartilage to underlying bone
-
Ushio K., Oka M., Hyon S., Hayami T., Yura S., Matsumura K., Toguchida J., and Nakamura T. Attachment of artificial cartilage to underlying bone. J. Biomed. Mat. Res. Part B: Appl. Biomat. 68B 1 (2003) 59-68
-
(2003)
J. Biomed. Mat. Res. Part B: Appl. Biomat.
, vol.68 B
, Issue.1
, pp. 59-68
-
-
Ushio, K.1
Oka, M.2
Hyon, S.3
Hayami, T.4
Yura, S.5
Matsumura, K.6
Toguchida, J.7
Nakamura, T.8
-
28
-
-
0042028257
-
Partial hemiarthroplasty for the treatment of osteonecrosis of the femoral head
-
Ushio K., Oka M., Hyon S.H., Yura S., Toguchida J., and Nakamura T. Partial hemiarthroplasty for the treatment of osteonecrosis of the femoral head. J. Bone Joint Surg. 85-B 6 (2003) 922-930
-
(2003)
J. Bone Joint Surg.
, vol.85 -B
, Issue.6
, pp. 922-930
-
-
Ushio, K.1
Oka, M.2
Hyon, S.H.3
Yura, S.4
Toguchida, J.5
Nakamura, T.6
-
29
-
-
0031214403
-
The normal stress effect and equilibrium friction coefficient of articular cartilage under steady frictional shear
-
Aug
-
Wang H.Q., and Ateshian G.A. The normal stress effect and equilibrium friction coefficient of articular cartilage under steady frictional shear. J. BioMech. 30 8 (1997) 771-776 Aug
-
(1997)
J. BioMech.
, vol.30
, Issue.8
, pp. 771-776
-
-
Wang, H.Q.1
Ateshian, G.A.2
-
30
-
-
2342435756
-
Synthesis and characterization of partially biodegradable, Temperature and pH sensitive Dex-MA/PNIPAAm hydrogels
-
Zhang X., Wu D., and Chu C. Synthesis and characterization of partially biodegradable, Temperature and pH sensitive Dex-MA/PNIPAAm hydrogels. Biomaterials 25 (2004) 4719-4730
-
(2004)
Biomaterials
, vol.25
, pp. 4719-4730
-
-
Zhang, X.1
Wu, D.2
Chu, C.3
|