메뉴 건너뛰기




Volumn 68, Issue 1, 2004, Pages 59-68

Attachment of Artificial Cartilage to Underlying Bone

Author keywords

Artificial cartilage; Composite osteochondral device; Injection molding; Polyvinyl alcohol hydrogel; Titanium fiber mesh

Indexed keywords

BONE; CARTILAGE; HIP PROSTHESES; IMPLANTS (SURGICAL); INJECTION MOLDING; JOINTS (ANATOMY); POLYVINYL ALCOHOLS;

EID: 0347986706     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/jbm.b.10076     Document Type: Article
Times cited : (41)

References (22)
  • 1
    • 0018970317 scopus 로고
    • The optimum pore size for the fixation of porous surfaced metal implants by the ingrowth of bone
    • Bobyn JD, Pilliar RM, Cameron HU, Weatherly GC. The optimum pore size for the fixation of porous surfaced metal implants by the ingrowth of bone. Clin Orthop 1980;150:263-270.
    • (1980) Clin Orthop , vol.150 , pp. 263-270
    • Bobyn, J.D.1    Pilliar, R.M.2    Cameron, H.U.3    Weatherly, G.C.4
  • 3
    • 0028969471 scopus 로고
    • Current concepts review: Non-traumatic avascular necrosis of the femoral head
    • Mont MA, Hungerford DS. Current concepts review: Non-traumatic avascular necrosis of the femoral head. J Bone Joint Surg 1995;77A:459-474.
    • (1995) J Bone Joint Surg , vol.77 A , pp. 459-474
    • Mont, M.A.1    Hungerford, D.S.2
  • 4
    • 0025614954 scopus 로고
    • Development of an artificial articular cartilage
    • Oka M, Noguchi T, Kumar P, et al. Development of an artificial articular cartilage. Clin Mater 1990;6:361-381.
    • (1990) Clin Mater , vol.6 , pp. 361-381
    • Oka, M.1    Noguchi, T.2    Kumar, P.3
  • 5
    • 0002672782 scopus 로고
    • Load-bearing mechanisms of natural and artificial joints
    • Imura S, Akamatsu N, Azuma H, editors. New York: Springer
    • Oka M. Load-bearing mechanisms of natural and artificial joints. In: Imura S, Akamatsu N, Azuma H, editors. Hip biomechanics. New York: Springer; 1993. pp 255-263.
    • (1993) Hip Biomechanics , pp. 255-263
    • Oka, M.1
  • 6
    • 0002485279 scopus 로고
    • Biomechanics of natural and artificial joints
    • Niwa S, Perren SM, editors. Berlin: Springer
    • Oka M, Ikeuchi K, Tstsumi S. Biomechanics of natural and artificial joints. In: Niwa S, Perren SM, editors. Biomechanics in orthopedics. Berlin: Springer; 1992. p 282-298.
    • (1992) Biomechanics in Orthopedics , pp. 282-298
    • Oka, M.1    Ikeuchi, K.2    Tstsumi, S.3
  • 7
    • 0024714994 scopus 로고
    • Preparation of transparent poly (vinyl alcohol) hydrogel
    • Hyon SH, Cha W, Ikada Y. Preparation of transparent poly (vinyl alcohol) hydrogel. Polym Bull 1989;22:119-122.
    • (1989) Polym Bull , vol.22 , pp. 119-122
    • Hyon, S.H.1    Cha, W.2    Ikada, Y.3
  • 8
    • 0030534423 scopus 로고    scopus 로고
    • Mechanical and wear properties of poly (vinyl alcohol) hydrogels
    • Cha Wi, Hyon SH, Oka M, et al. Mechanical and wear properties of poly (vinyl alcohol) hydrogels. Macromol Symp 1996;109:115-126.
    • (1996) Macromol Symp , vol.109 , pp. 115-126
    • Cha, W.1    Hyon, S.H.2    Oka, M.3
  • 9
    • 0033631534 scopus 로고    scopus 로고
    • Development of artificial articular cartilage
    • Oka M, Ushio K, Kumar P, et al. Development of artificial articular cartilage. Proc Inst Mech Eng [H] 2000;214(1):59-68.
    • (2000) Proc Inst Mech Eng [H] , vol.214 , Issue.1 , pp. 59-68
    • Oka, M.1    Ushio, K.2    Kumar, P.3
  • 11
    • 0026168125 scopus 로고
    • Poly (vinyl alcohol) hydrogel as an artificial articular cartilage: Evaluation of biocompatibility
    • Noguchi T, Yamamuro T, Oka M, et al. Poly (vinyl alcohol) hydrogel as an artificial articular cartilage: Evaluation of biocompatibility. J Appl Biomater 1991;2:101-107.
    • (1991) J Appl Biomater , vol.2 , pp. 101-107
    • Noguchi, T.1    Yamamuro, T.2    Oka, M.3
  • 12
    • 0001084660 scopus 로고
    • Joint reactions against polymer particles: PVA-H versus UHMWPE
    • Delecrin J, Oka M, Kumar P. Joint reactions against polymer particles: PVA-H versus UHMWPE. J Jpn Orthop Assoc 1990;64:S1395.
    • (1990) J Jpn Orthop Assoc , vol.64
    • Delecrin, J.1    Oka, M.2    Kumar, P.3
  • 13
    • 0030664969 scopus 로고    scopus 로고
    • Synthetic osteochondral replacement of the femoral articular surface
    • Oka M, Chang YS, Nakamura T, et al. Synthetic osteochondral replacement of the femoral articular surface. J Bone Joint Surg Br 1997;79:1003-1007.
    • (1997) J Bone Joint Surg Br , vol.79 , pp. 1003-1007
    • Oka, M.1    Chang, Y.S.2    Nakamura, T.3
  • 14
    • 0028675291 scopus 로고
    • Bone formation and remodeling around implanted materials under load bearing conditions
    • Chang YS, Oka M, Nakamura T. Bone formation and remodeling around implanted materials under load bearing conditions. Clin Mater 1995;17:181-187.
    • (1995) Clin Mater , vol.17 , pp. 181-187
    • Chang, Y.S.1    Oka, M.2    Nakamura, T.3
  • 15
    • 0030175965 scopus 로고    scopus 로고
    • Significance of interstitial bone ingrowth under load-bearing conditions. A comparison between solid and porous implant materials
    • Chang YS, Oka M, Kobayashi M, et al. Significance of interstitial bone ingrowth under load-bearing conditions. A comparison between solid and porous implant materials. Biomaterials 1996;17:1141-1148.
    • (1996) Biomaterials , vol.17 , pp. 1141-1148
    • Chang, Y.S.1    Oka, M.2    Kobayashi, M.3
  • 16
    • 0002578067 scopus 로고    scopus 로고
    • Development of artificial intervertebral disc using polyvinyl alcohol hydrogels
    • Stein H, Suk SI, Leung PC, et al., editors. London: Freund Publishing House Ltd
    • Yura S, Oka M, Ushio K, et al. Development of artificial intervertebral disc using polyvinyl alcohol hydrogels. In: Stein H, Suk SI, Leung PC, et al., editors. SIROT99. London: Freund Publishing House Ltd; 1999. p 371-376.
    • (1999) SIROT99 , pp. 371-376
    • Yura, S.1    Oka, M.2    Ushio, K.3
  • 18
    • 0034749064 scopus 로고    scopus 로고
    • Biomechanics and repair of articular cartilage
    • Oka M. Biomechanics and repair of articular cartilage. J Orthop Sci 2001;6:448-456.
    • (2001) J Orthop Sci , vol.6 , pp. 448-456
    • Oka, M.1
  • 19
    • 0346840369 scopus 로고    scopus 로고
    • Artificial bone connection prosthesis. May 1994; U.S. Patent No. 5,314,478
    • Oka M, Hyon SH, Ikada Y, Okiatsu K. Artificial bone connection prosthesis. May 1994; U.S. Patent No. 5,314,478.
    • Oka, M.1    Hyon, S.H.2    Ikada, Y.3    Okiatsu, K.4
  • 20
    • 0029311022 scopus 로고
    • Design concepts for an intervertebral disc spacer: Multi-durometer composite design
    • Hawkins MV, Laugrana NA, Parsons J. Design concepts for an intervertebral disc spacer: Multi-durometer composite design. J Appl Biomater 1995;6:117-123.
    • (1995) J Appl Biomater , vol.6 , pp. 117-123
    • Hawkins, M.V.1    Laugrana, N.A.2    Parsons, J.3
  • 21
    • 0017487435 scopus 로고
    • Development of semicrystalline poly(vinyl alcohol) hydrogels for biomedical applications
    • Peppas N, Merrill EW. Development of semicrystalline poly(vinyl alcohol) hydrogels for biomedical applications. J Biomed Mater Res 1977;11:423-434.
    • (1977) J Biomed Mater Res , vol.11 , pp. 423-434
    • Peppas, N.1    Merrill, E.W.2
  • 22
    • 0018286915 scopus 로고
    • Characterisation of homogeneous and pseudocomposite homopolymers and copolymers for articular cartilage replacement
    • Peppas N. Characterisation of homogeneous and pseudocomposite homopolymers and copolymers for articular cartilage replacement. Biomat Med Dev Art Org 1979;7:421-433.
    • (1979) Biomat Med Dev Art Org , vol.7 , pp. 421-433
    • Peppas, N.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.