메뉴 건너뛰기




Volumn 15, Issue 5, 2009, Pages 425-429

Computerized tomographic pulmonary angiography versus ventilation perfusion lung scanning for the diagnosis of pulmonary embolism

Author keywords

Computed tomographic pulmonary angiography; Deep vein thrombosis; Pulmonary embolism; Ventilation perfusion lung scanning

Indexed keywords

D DIMER;

EID: 68949173698     PISSN: 10705287     EISSN: 15316971     Source Type: Journal    
DOI: 10.1097/MCP.0b013e32832d6b98     Document Type: Review
Times cited : (34)

References (37)
  • 1
    • 0025891903 scopus 로고
    • A population-based perspective of the hospital incidence and case-fatality rates of deep vein thrombosis and pulmonary embolism
    • Anderson FA, Wheeler HB, Goldberg RJ, etal. A population-based perspective of the hospital incidence and case-fatality rates of deep vein thrombosis and pulmonary embolism. Arch Intern Med 1991; 151:933-938.
    • (1991) Arch Intern Med , vol.151 , pp. 933-938
    • Anderson, F.A.1    Wheeler, H.B.2    Goldberg, R.J.3
  • 2
    • 0025354523 scopus 로고
    • Value of the ventilation/perfusion scan in acute pulmonary embolism: Results of the Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED)
    • The PIOPED Investigators.
    • The PIOPED Investigators. Value of the ventilation/perfusion scan in acute pulmonary embolism: results of the Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED). JAMA 1990; 263:2753-2759.
    • (1990) JAMA , vol.263 , pp. 2753-2759
  • 3
    • 33744503127 scopus 로고    scopus 로고
    • Multidetector computed tomography for acute pulmonary embolism.
    • For the PIOPED II Investigators
    • Stein PD, Fowler SE, Goodman LR, et al., for the PIOPED II Investigators. Multidetector computed tomography for acute pulmonary embolism. N Engl J Med 2006; 354:2317-2327.
    • (2006) N Engl J Med , vol.354 , pp. 2317-2327
    • Stein, P.D.1    Fowler, S.E.2    Goodman, L.R.3
  • 4
    • 37649023943 scopus 로고    scopus 로고
    • Don't bury the V/Q scan: It's as good as multidetector CT angiograms with a lot less radiation exposure.
    • Freeman LM. Don't bury the V/Q scan: it's as good as multidetector CT angiograms with a lot less radiation exposure. J Nucl Med 2008; 49:5-8.
    • (2008) J Nucl Med , vol.49 , pp. 5-8
    • Freeman, L.M.1
  • 5
    • 33947694585 scopus 로고    scopus 로고
    • Diagnostic pathways in acute pulmonary embolism: Recommendations of the PIOPED II investigators.
    • Stein PD, Woodard PK, Weg JG, et al. Diagnostic pathways in acute pulmonary embolism: recommendations of the PIOPED II investigators. Am J Med 2006; 119:1048-1055.
    • (2006) Am J Med , vol.119 , pp. 1048-1055
    • Stein, P.D.1    Woodard, P.K.2    Weg, J.G.3
  • 6
    • 4143121708 scopus 로고    scopus 로고
    • D-dimer for the exclusion of deep vein thrombosis and pulmonary embolism: A systematic review.
    • Stein PD, Hull RD, Patel KC, et al. D-dimer for the exclusion of deep vein thrombosis and pulmonary embolism: a systematic review. Ann Intern Med 2004; 140:589-602.
    • (2004) Ann Intern Med , vol.140 , pp. 589-602
    • Stein, P.D.1    Hull, R.D.2    Patel, K.C.3
  • 7
    • 27144440472 scopus 로고    scopus 로고
    • Use of spiral computerized tomography contrast angiography to exclude the diagnosis of pulmonary embolism in the emergency department.
    • Anderson DR, Kovacs MJ, Dennie C, et al. Use of spiral computerized tomography contrast angiography to exclude the diagnosis of pulmonary embolism in the emergency department. J Emerg Med 2005; 29:399-404.
    • (2005) J Emerg Med , vol.29 , pp. 399-404
    • Anderson, D.R.1    Kovacs, M.J.2    Dennie, C.3
  • 8
    • 68949166814 scopus 로고    scopus 로고
    • Incidence and predictors of repeated computed tomographic pulmonary angiography in emergency department patients
    • [Epub ahead of print]
    • Kline JA, Courtney DM, Beam DM, etal. Incidence and predictors of repeated computed tomographic pulmonary angiography in emergency department patients. Ann Emerg Med 2008 [Epub ahead of print].
    • (2008) Ann Emerg Med
    • Kline, J.A.1    Courtney, D.M.2    Beam, D.M.3
  • 9
    • 34548479754 scopus 로고    scopus 로고
    • Examination of hospital referral practices for CT pulmonary angiography.
    • Kiley CA, Lowry KJ, Mysliwiec V. Examination of hospital referral practices for CT pulmonary angiography. J Hosp Med; 2:253-257.
    • J Hosp Med , vol.2 , pp. 253-257
    • Kiley, C.A.1    Lowry, K.J.2    Mysliwiec, V.3
  • 10
    • 49149094139 scopus 로고    scopus 로고
    • CT angiography in the evaluation of acute pulmonary embolus
    • Costantino MM, Randall G, Gosselin M, etal. CT angiography in the evaluation of acute pulmonary embolus. AJR Am J Roentgenol 2008; 191:471-474.
    • (2008) AJR Am J Roentgenol , vol.191 , pp. 471-474
    • Costantino, M.M.1    Randall, G.2    Gosselin, M.3
  • 11
    • 34548057085 scopus 로고    scopus 로고
    • Discordance between CT and angiography in the PIOPED II study.
    • Wittram C, Waltman AC, Shepard J-AO, et al. Discordance between CT and angiography in the PIOPED II study. Radiol 2007; 244:883-889.
    • (2007) Radiol , vol.244 , pp. 883-889
    • Wittram, C.1    Waltman, A.C.2    J-Ao, S.3
  • 12
    • 34247597201 scopus 로고    scopus 로고
    • How i do it: CT pulmonary angiography.
    • Wittram C. How I do it: CT pulmonary angiography. AJR Am J Roentgenol 2007; 188:1255-1261.
    • (2007) AJR Am J Roentgenol , vol.188 , pp. 1255-1261
    • Wittram, C.1
  • 13
    • 52049119038 scopus 로고    scopus 로고
    • Multidetector CT pulmonary angiography features of pulmonary embolus.
    • Hoang JK, Lee WK, Hennessy OF. Multidetector CT pulmonary angiography features of pulmonary embolus. J Med Imaging Radiat Oncol 2008; 52:307-317.
    • (2008) J Med Imaging Radiat Oncol , vol.52 , pp. 307-317
    • Hoang, J.K.1    Lee, W.K.2    Hennessy, O.F.3
  • 14
    • 51349147651 scopus 로고    scopus 로고
    • Venous thromboembolism and occult malignancy: Simultaneous detection during pulmonary CT angiography with CT venography.
    • Bierry G, Holl N, Kellner F, et al. Venous thromboembolism and occult malignancy: simultaneous detection during pulmonary CT angiography with CT venography. AJR Am J Roentgenol 2008; 191:885-889.
    • (2008) AJR Am J Roentgenol , vol.191 , pp. 885-889
    • Bierry, G.1    Holl, N.2    Kellner, F.3
  • 15
    • 53249127374 scopus 로고    scopus 로고
    • CT angiography findings of the left atrium and right ventricle in patients with massive pulmonary embolism.
    • Ocak I, Fuhrman C. CT angiography findings of the left atrium and right ventricle in patients with massive pulmonary embolism. AJR Am J Roentgenol 2008; 191:1072-1076.
    • (2008) AJR Am J Roentgenol , vol.191 , pp. 1072-1076
    • Ocak, I.1    Fuhrman, C.2
  • 16
    • 56649083640 scopus 로고    scopus 로고
    • Massive pulmonary emboli and CT pulmonary angiography.
    • Findik S, Erkan L, Light RW, et al. Massive pulmonary emboli and CT pulmonary angiography. Respiration 2008; 76:412-503.
    • (2008) Respiration , vol.76 , pp. 412-503
    • Findik, S.1    Erkan, L.2    Light, R.W.3
  • 17
    • 37349096405 scopus 로고    scopus 로고
    • Computed tomographic pulmonary angiography vs ventilation-perfusion lung scanning in patients with suspected pulmonary embolism: A randomized controlled trial
    • Anderson DR, Kahn SR, Rodger MA, etal. Computed tomographic pulmonary angiography vs ventilation-perfusion lung scanning in patients with suspected pulmonary embolism: a randomized controlled trial. JAMA 2007; 298:2743-2753.
    • (2007) JAMA , vol.298 , pp. 2743-2753
    • Anderson, D.R.1    Kahn, S.R.2    Rodger, M.A.3
  • 18
    • 40949140104 scopus 로고    scopus 로고
    • Acute pulmonary embolism: Sensitivity and specificity of ventilation-perfusion scintigraphy in PIOPED II study.
    • Sostman HD, Stein PD, Gottschalk A, et al. Acute pulmonary embolism: sensitivity and specificity of ventilation-perfusion scintigraphy in PIOPED II study. Radiology 2008; 246:941-946.
    • (2008) Radiology , vol.246 , pp. 941-946
    • Sostman, H.D.1    Stein, P.D.2    Gottschalk, A.3
  • 19
    • 34548587073 scopus 로고    scopus 로고
    • Very low probability interpretation of V/Q lung scans in combination with low probability objective clinical assessment reliably excludes pulmonary embolism: Data from PIOPED II
    • Gottschalk A, Stein PD, Sostman HD, etal. Very low probability interpretation of V/Q lung scans in combination with low probability objective clinical assessment reliably excludes pulmonary embolism: data from PIOPED II. J Nucl Med 2007; 48:1411-1415.
    • (2007) J Nucl Med , vol.48 , pp. 1411-1415
    • Gottschalk, A.1    Stein, P.D.2    Sostman, H.D.3
  • 20
    • 33750633303 scopus 로고    scopus 로고
    • Improving the diagnostic performance of lung scintigraphy in suspected pulmonary embolic disease.
    • Gleeson FV, Turner S, Scarsbrook AF. Improving the diagnostic performance of lung scintigraphy in suspected pulmonary embolic disease. Clin Radiol 2006; 51:1010-1015.
    • (2006) Clin Radiol , vol.51 , pp. 1010-1015
    • Gleeson, F.V.1    Turner, S.2    Scarsbrook, A.F.3
  • 21
    • 34250673663 scopus 로고    scopus 로고
    • Ventilation-perfusion scintigraphy is more sensitive than multidetector CTPA in detecting chronic thromboembolic pulmonary disease as a treatable cause of pulmonary hypertension.
    • Tunariu N, Gibbs SJR, Win Z, et al. Ventilation-perfusion scintigraphy is more sensitive than multidetector CTPA in detecting chronic thromboembolic pulmonary disease as a treatable cause of pulmonary hypertension. J Nucl Med 2007; 48:680-684.
    • (2007) J Nucl Med , vol.48 , pp. 680-684
    • Tunariu, N.1    Gibbs, S.J.R.2    Win, Z.3
  • 22
    • 42049095662 scopus 로고    scopus 로고
    • Diagnosis of pulmonary embolism by multidetector CT alone or combined with venous ultrasonography of the leg: A randomized noninferiority trial.
    • Righini M, Le Gal G, Aukesky D, et al. Diagnosis of pulmonary embolism by multidetector CT alone or combined with venous ultrasonography of the leg: a randomized noninferiority trial. Lancet 2008; 371:1343-1352.
    • (2008) Lancet , vol.371 , pp. 1343-1352
    • Righini, M.1    Le Gal, G.2    Aukesky, D.3
  • 23
    • 59849095088 scopus 로고    scopus 로고
    • Complete venous ultrasound in outpatients with suspected pulmonary embolism
    • Righini M, LeGal G, Aujesky D, etal. Complete venous ultrasound in outpatients with suspected pulmonary embolism. J Thromb Haemost 2008; 7:406-412.
    • (2008) J Thromb Haemost , vol.7 , pp. 406-412
    • Righini, M.1    Legal, G.2    Aujesky, D.3
  • 24
    • 36048951084 scopus 로고    scopus 로고
    • CT venography vs ultrasound in the diagnosis of thromboembolic disease in patients with clinical suspicion of pulmonary embolism.
    • Garcia-Bolado A, Del Cura JL. CT venography vs ultrasound in the diagnosis of thromboembolic disease in patients with clinical suspicion of pulmonary embolism. Emerg Radiol 2007; 14:403-409.
    • (2007) Emerg Radiol , vol.14 , pp. 403-409
    • Garcia-Bolado, A.1    Del Cura, J.L.2
  • 25
    • 35649003088 scopus 로고    scopus 로고
    • CT venography and compression sonography are diagnostically equivalent: Data from PIOPED II.
    • Goodman LR, Stein PD, Matta F, et al. CT venography and compression sonography are diagnostically equivalent: data from PIOPED II. AJR Am J Roentgenol 2007; 189:1071-1076.
    • (2007) AJR Am J Roentgenol , vol.189 , pp. 1071-1076
    • Goodman, L.R.1    Stein, P.D.2    Matta, F.3
  • 26
    • 34247624184 scopus 로고    scopus 로고
    • American College of Radiology white paper on radiation dose in medicine.
    • Amis ES, Butler PF, Applegate KE, et al. American College of Radiology white paper on radiation dose in medicine. J Am Coll Radiol 2007; 4:272-284.
    • (2007) J Am Coll Radiol , vol.4 , pp. 272-284
    • Amis, E.S.1    Butler, P.F.2    Applegate, K.E.3
  • 27
    • 36249002355 scopus 로고    scopus 로고
    • Radiation dose from contemporary cardiothoracic multidetector CT protocols with anthropomorphic female phantom: Implications for cancer induction.
    • Hurwitz LM, Reiman RE, Yoshizumi TT, et al. Radiation dose from contemporary cardiothoracic multidetector CT protocols with anthropomorphic female phantom: implications for cancer induction. Radiology 2007; 245:742-750.
    • (2007) Radiology , vol.245 , pp. 742-750
    • Hurwitz, L.M.1    Reiman, R.E.2    Yoshizumi, T.T.3
  • 28
    • 58149271097 scopus 로고    scopus 로고
    • Radiation dose savings for adult pulmonary embolus 64-MDCT using Bismuth breast shields, lower peak kilo voltage and automatic tube current modulation.
    • Hurwitz LM, Yoshizumi TT, Goodman PH, et al. Radiation dose savings for adult pulmonary embolus 64-MDCT using Bismuth breast shields, lower peak kilo voltage and automatic tube current modulation. AJR Am J Roentgenol 2009; 192:244-253.
    • (2009) AJR Am J Roentgenol , vol.192 , pp. 244-253
    • Hurwitz, L.M.1    Yoshizumi, T.T.2    Goodman, P.H.3
  • 29
    • 35348977748 scopus 로고    scopus 로고
    • Image quality and radiation exposure at pulmonary CT angiography with 100- or 120-kVp protocol: Prospective randomized study.
    • Heyer CM, Mohr PS, Lemburg SP, et al. Image quality and radiation exposure at pulmonary CT angiography with 100- or 120-kVp protocol: prospective randomized study. Radiology 2007; 245:577-583.
    • (2007) Radiology , vol.245 , pp. 577-583
    • Heyer, C.M.1    Mohr, P.S.2    Lemburg, S.P.3
  • 30
    • 59649088090 scopus 로고    scopus 로고
    • Patient exposure and image quality of low-dose pulmonary computed tomography angiography: Comparison of 100- and 80-kVp protocols.
    • Szucs-Farkas Z, Kurmann L, Strautz T, et al. Patient exposure and image quality of low-dose pulmonary computed tomography angiography: comparison of 100- and 80-kVp protocols. Invest Radiol 2008; 43:871-876.
    • (2008) Invest Radiol , vol.43 , pp. 871-876
    • Szucs-Farkas, Z.1    Kurmann, L.2    Strautz, T.3
  • 31
    • 6944227532 scopus 로고    scopus 로고
    • Tomographic imaging in the diagnosis of pulmonary embolism: A comparison between V/Q lung scintigraphy in SPECT technique and multislice spiral CT.
    • Reinartz P, Wildberger JE, Schaefer W, et al. Tomographic imaging in the diagnosis of pulmonary embolism: a comparison between V/Q lung scintigraphy in SPECT technique and multislice spiral CT. J Nucl Med 2004; 45:1501-1508.
    • (2004) J Nucl Med , vol.45 , pp. 1501-1508
    • Reinartz, P.1    Wildberger, J.E.2    Schaefer, W.3
  • 32
    • 34447555816 scopus 로고    scopus 로고
    • Prospective evaluation of the negative predictive value of V/Q SPECT using 99mTc-Technegas.
    • Leblanc M, Leveillee F, Turcotte E. Prospective evaluation of the negative predictive value of V/Q SPECT using 99mTc-Technegas. Nucl Med Comm 2007; 28:667-672.
    • (2007) Nucl Med Comm , vol.28 , pp. 667-672
    • Leblanc, M.1    Leveillee, F.2    Turcotte, E.3
  • 33
    • 51749124034 scopus 로고    scopus 로고
    • Ventilation/perfusion SPECT for diagnostics of pulmonary embolism in clinical practice.
    • Bajc M, Olsson B, Palmer, Jonson B. Ventilation/perfusion SPECT for diagnostics of pulmonary embolism in clinical practice. J Intern Med 2008; 264:379-387.
    • (2008) J Intern Med , vol.264 , pp. 379-387
    • Bajc, M.1    Olsson, B.2    Palmer Jonson, B.3
  • 34
    • 45749101644 scopus 로고    scopus 로고
    • Pulmonary embolism incidence is increasing with use of spiral computed tomography.
    • DeMonaco NA, Dang Q, Kapoor WN, Ragni MV. Pulmonary embolism incidence is increasing with use of spiral computed tomography. Am J Med 2008; 21:611-617.
    • (2008) Am J Med , vol.21 , pp. 611-617
    • Demonaco, N.A.1    Dang, Q.2    Kapoor, W.N.3    Ragni, M.V.4
  • 35
    • 39849091192 scopus 로고    scopus 로고
    • Increased diagnosis of pulmonary embolism without a corresponding decline in mortality during the CT era.
    • Burge AJ, Freeman KD, Klapper PJ, Haramati LB. Increased diagnosis of pulmonary embolism without a corresponding decline in mortality during the CT era. Clin Radiol 2009; 63:381-386.
    • (2009) Clin Radiol , vol.63 , pp. 381-386
    • Burge, A.J.1    Freeman, K.D.2    Klapper, P.J.3    Haramati, L.B.4
  • 36
    • 45849153477 scopus 로고    scopus 로고
    • Utilization patterns and diagnostic yield of 3421 consecutive multidetector row computed tomography pulmonary angiograms in a busy emergency department.
    • Donohoo JH, Mayo-Smith WW, Pezzullo JA, Egglin TK. Utilization patterns and diagnostic yield of 3421 consecutive multidetector row computed tomography pulmonary angiograms in a busy emergency department. J Comput Assist Tomogr 2008; 32:421-425.
    • (2008) J Comput Assist Tomogr , vol.32 , pp. 421-425
    • Donohoo, J.H.1    Mayo-Smith, W.W.2    Pezzullo, J.A.3    Egglin, T.K.4
  • 37
    • 35348885708 scopus 로고    scopus 로고
    • The rise of incidence of pulmonary embolus after joint arthroplasty: Is modern imaging to blame?
    • Parvizi J, Smith EB, Pulido L, etal. The rise of incidence of pulmonary embolus after joint arthroplasty: is modern imaging to blame? Clin Orthop Relat Res 2007; 463:107-113.
    • (2007) Clin Orthop Relat Res , vol.463 , pp. 107-113
    • Parvizi, J.1    Smith, E.B.2    Pulido, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.