메뉴 건너뛰기




Volumn 59, Issue 6, 2009, Pages 683-694

Real-time airflow rate measurements from mechanically ventilated animal buildings

Author keywords

[No Author keywords available]

Indexed keywords

ANIMALS; ATMOSPHERIC PRESSURE; HOUSING;

EID: 68849114809     PISSN: 10962247     EISSN: 21622906     Source Type: Journal    
DOI: 10.3155/1047-3289.59.6.683     Document Type: Article
Times cited : (36)

References (11)
  • 2
    • 0002550578 scopus 로고    scopus 로고
    • Assessment of Techniques for Measuring the Ventilation Rate Using an Experimental Building Section
    • Demmers, T.G.M., Burgess, L.R.; Phillips, V.R.; Clark, J.A.; Wathes, C.M. Assessment of Techniques for Measuring the Ventilation Rate Using an Experimental Building Section; J. Agric. Eng. Res. 2000, 76, 71-81.
    • (2000) J. Agric. Eng. Res , vol.76 , pp. 71-81
    • Demmers, T.G.M.1    Burgess, L.R.2    Phillips, V.R.3    Clark, J.A.4    Wathes, C.M.5
  • 3
    • 0032078644 scopus 로고    scopus 로고
    • Evaluation of a Freely Rotating Impeller to Measure Fan Airflow Rates in Livestock Buildings
    • Maghirang, R.G.; Liu, Y.; Chung, D.S. Evaluation of a Freely Rotating Impeller to Measure Fan Airflow Rates in Livestock Buildings; Trans. ASAE 1998, 41, 819-824.
    • (1998) Trans. ASAE , vol.41 , pp. 819-824
    • Maghirang, R.G.1    Liu, Y.2    Chung, D.S.3
  • 4
    • 85016442595 scopus 로고
    • Sensor for Continuous Measurement of the Ventilation Rate in Livestock Buildings
    • Berckmans, D.; Vandenbroeck, P.; Goedseels, V. Sensor for Continuous Measurement of the Ventilation Rate in Livestock Buildings; Indoor Air 1991, 3, 323-336.
    • (1991) Indoor Air , vol.3 , pp. 323-336
    • Berckmans, D.1    Vandenbroeck, P.2    Goedseels, V.3
  • 7
    • 11144296280 scopus 로고    scopus 로고
    • Fan Assessment Numeration System (FANS) Design and Calibration Specifications
    • Gates, R.S.; Casey, K.D.; Xin, H.; Wheeler, E.F.; Simmons, J.D. Fan Assessment Numeration System (FANS) Design and Calibration Specifications; Trans. ASAE 2004, 47, 1709-1715.
    • (2004) Trans. ASAE , vol.47 , pp. 1709-1715
    • Gates, R.S.1    Casey, K.D.2    Xin, H.3    Wheeler, E.F.4    Simmons, J.D.5
  • 9
    • 0037393542 scopus 로고    scopus 로고
    • Air Emission Measurements at Livestock Houses: A Hideand-Seek Challenge to Find the Numbers
    • Heber, A.J. Air Emission Measurements at Livestock Houses: a Hideand-Seek Challenge to Find the Numbers; Resource 2003, 10, 7-8.
    • (2003) Resource , vol.10 , pp. 7-8
    • Heber, A.J.1
  • 10
    • 0042020576 scopus 로고    scopus 로고
    • Standard 210-99; American National Standards Institute/Air Movement and Control Association: Arlington Heights, IL
    • Laboratory Methods of Testing Fans for Aerodynamic Performance Rating; Standard 210-99; American National Standards Institute/Air Movement and Control Association: Arlington Heights, IL, 1999.
    • (1999) Laboratory Methods of Testing Fans for Aerodynamic Performance Rating


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.