Volumn 50, Issue 11, 2009, Pages 2818-2825

Experimental investigation for total equivalent temperature difference (TETD) values of building walls and flat roofs

Author keywords

Cooling load; Decrement factor; Heat gain; Time lag; Total equivalent temperature difference

Indexed keywords

COOLING LOAD; DECREMENT FACTOR; HEAT GAIN; TIME LAG; TOTAL EQUIVALENT TEMPERATURE DIFFERENCE;

EID: 68849113924     PISSN: 01968904     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enconman.2009.06.027     Document Type: Article
Times cited : (39)

References (26)
  • 1
    • 33847009542 scopus 로고    scopus 로고
    • Cooling load calculations in subtropical climate
    • Mui K.W., and Wong L.T. Cooling load calculations in subtropical climate. Build Environ 42 (2007) 2498-2504
    • (2007) Build Environ , vol.42 , pp. 2498-2504
    • Mui, K.W.1    Wong, L.T.2
  • 2
    • 40749135892 scopus 로고    scopus 로고
    • Development of CLTD values for buildings located in Kolkata, India
    • Bansal K., Chowdhury S., and Gopal M.R. Development of CLTD values for buildings located in Kolkata, India. Appl Therm Eng 28 (2008) 1127-1137
    • (2008) Appl Therm Eng , vol.28 , pp. 1127-1137
    • Bansal, K.1    Chowdhury, S.2    Gopal, M.R.3
  • 3
    • 16844371630 scopus 로고    scopus 로고
    • Periodic solution of transient heat flow through multilayer walls and flat roofs by complex finite Fourier transform technique
    • Yumrutaş R., Unsal M., and Kanoǧlu M. Periodic solution of transient heat flow through multilayer walls and flat roofs by complex finite Fourier transform technique. Build Environ 40 (2005) 1117-1125
    • (2005) Build Environ , vol.40 , pp. 1117-1125
    • Yumrutaş, R.1    Unsal, M.2    Kanoǧlu, M.3
  • 4
    • 33845587902 scopus 로고    scopus 로고
    • Estimation of total equivalent temperature difference values for multilayer walls and flat roofs by using periodic solution
    • Yumrutaş R., Önder K., and Yi{dotless}ldi{dotless}ri{dotless}m E. Estimation of total equivalent temperature difference values for multilayer walls and flat roofs by using periodic solution. Build Environ 42 5 (2007) 1878-1885
    • (2007) Build Environ , vol.42 , Issue.5 , pp. 1878-1885
    • Yumrutaş, R.1    Önder, K.2    Yildirim, E.3
  • 5
    • 68849132308 scopus 로고    scopus 로고
    • ASHRAE handbook - fundamentals. Atlanta: ASHRAE; 1993.
    • ASHRAE handbook - fundamentals. Atlanta: ASHRAE; 1993.
  • 7
    • 0027242938 scopus 로고
    • The CLTD/SCL/CLF cooling load calculation method
    • Spitler J.D., McQuiston F.C., and Lindsey K.L. The CLTD/SCL/CLF cooling load calculation method. ASHRAE Trans 10 10 (1993) 183-192
    • (1993) ASHRAE Trans , vol.10 , Issue.10 , pp. 183-192
    • Spitler, J.D.1    McQuiston, F.C.2    Lindsey, K.L.3
  • 8
    • 0346509534 scopus 로고    scopus 로고
    • Utilizing transfer function method for hourly cooling load calculations
    • AL-Rabghi O.M.A., and Al-Johani K.M. Utilizing transfer function method for hourly cooling load calculations. Energy Convers Manage 38 4 (1997) 319-332
    • (1997) Energy Convers Manage , vol.38 , Issue.4 , pp. 319-332
    • AL-Rabghi, O.M.A.1    Al-Johani, K.M.2
  • 10
    • 0001437599 scopus 로고
    • A study to categorize walls and roofs on the basis of thermal response
    • Harris S.M., and McQuiston F.C. A study to categorize walls and roofs on the basis of thermal response. ASHRAE Trans 3187 RP-472 (1988)
    • (1988) ASHRAE Trans , vol.3187 , Issue.RP-472
    • Harris, S.M.1    McQuiston, F.C.2
  • 11
    • 0009402557 scopus 로고
    • Classification of 200, 640 parametric zones for cooling load calculation method
    • Sowell E.F. Classification of 200, 640 parametric zones for cooling load calculation method. ASHRAE Trans 94 2 (1988)
    • (1988) ASHRAE Trans , vol.94 , Issue.2
    • Sowell, E.F.1
  • 12
    • 34347273724 scopus 로고    scopus 로고
    • The effect of south wall's outdoor absorption coefficient on time lag, decrement factor and temperature variations
    • Kontoleon K.J., and Bikas D.K. The effect of south wall's outdoor absorption coefficient on time lag, decrement factor and temperature variations. Energy Build 39 (2007) 1011-1018
    • (2007) Energy Build , vol.39 , pp. 1011-1018
    • Kontoleon, K.J.1    Bikas, D.K.2
  • 13
    • 40949148641 scopus 로고    scopus 로고
    • The influence of wall orientation and exterior surface solar absorptivity on time lag and decrement factor in the Greek region
    • Kontoleon K.J., and Eumorfopoulou E.A. The influence of wall orientation and exterior surface solar absorptivity on time lag and decrement factor in the Greek region. Renew Energy 33 (2008) 1652-1664
    • (2008) Renew Energy , vol.33 , pp. 1652-1664
    • Kontoleon, K.J.1    Eumorfopoulou, E.A.2
  • 14
    • 0032188268 scopus 로고    scopus 로고
    • Effects of wall's thermophysical properties on time lag and decrement factor
    • Asan H., and Sancaktar Y.S. Effects of wall's thermophysical properties on time lag and decrement factor. Energy Build 28 (1998) 159-166
    • (1998) Energy Build , vol.28 , pp. 159-166
    • Asan, H.1    Sancaktar, Y.S.2
  • 15
    • 0032210313 scopus 로고    scopus 로고
    • Effects of wall's insulation thickness and position on time lag and decrement factor
    • Asan H. Effects of wall's insulation thickness and position on time lag and decrement factor. Energy Build 28 (1998) 299-305
    • (1998) Energy Build , vol.28 , pp. 299-305
    • Asan, H.1
  • 16
    • 0033735016 scopus 로고    scopus 로고
    • Investigation of wall's optimum insulation position from maximum time lag and minimum decrement factor point of view
    • Asan H. Investigation of wall's optimum insulation position from maximum time lag and minimum decrement factor point of view. Energy Build 32 (2000) 197-203
    • (2000) Energy Build , vol.32 , pp. 197-203
    • Asan, H.1
  • 17
    • 30444450706 scopus 로고    scopus 로고
    • Numerical computation of time lags and decrement factors for different building materials
    • Asan H. Numerical computation of time lags and decrement factors for different building materials. Build Environ 41 (2006) 615-620
    • (2006) Build Environ , vol.41 , pp. 615-620
    • Asan, H.1
  • 18
    • 0036497461 scopus 로고    scopus 로고
    • Experimental and theoretical investigation of effects of wall's thermophysical properties on time lag and decrement factor
    • Ulgen K. Experimental and theoretical investigation of effects of wall's thermophysical properties on time lag and decrement factor. Energy Build 34 (2002) 273-278
    • (2002) Energy Build , vol.34 , pp. 273-278
    • Ulgen, K.1
  • 19
    • 23744445596 scopus 로고    scopus 로고
    • The dynamic thermal characteristics of lightweight building elements with a forced ventilated cavity and radiation barriers
    • Cerne B., and Medved S. The dynamic thermal characteristics of lightweight building elements with a forced ventilated cavity and radiation barriers. Energy Build 37 (2005) 972-981
    • (2005) Energy Build , vol.37 , pp. 972-981
    • Cerne, B.1    Medved, S.2
  • 23
    • 1142306054 scopus 로고    scopus 로고
    • Experimental investigation of thermal performance of a solar assisted heat pump system with an energy storage
    • Yumrutaş R., and Kaşka O. Experimental investigation of thermal performance of a solar assisted heat pump system with an energy storage. Int J Energy Res 28 (2004) 163-175
    • (2004) Int J Energy Res , vol.28 , pp. 163-175
    • Yumrutaş, R.1    Kaşka, O.2
  • 24
    • 0037697088 scopus 로고    scopus 로고
    • Generation of hourly solar radiation for inclined surfaces using monthly mean sunshine duration in Algeria
    • Mefti A., Bouroubi M.Y., and Adane A. Generation of hourly solar radiation for inclined surfaces using monthly mean sunshine duration in Algeria. Energy Convers Manage 44 (2003) 3125-3141
    • (2003) Energy Convers Manage , vol.44 , pp. 3125-3141
    • Mefti, A.1    Bouroubi, M.Y.2    Adane, A.3
  • 25
    • 58949083694 scopus 로고    scopus 로고
    • Theoretical and experimental investigation of total equivalent temperature difference (TETD) values for building walls and flat roofs in Turkey
    • Kaşka O., Yumrutaş R., and Arpa O. Theoretical and experimental investigation of total equivalent temperature difference (TETD) values for building walls and flat roofs in Turkey. Appl Energy 86 (2009) 737-747
    • (2009) Appl Energy , vol.86 , pp. 737-747
    • Kaşka, O.1    Yumrutaş, R.2    Arpa, O.3
  • 26
    • 2142780676 scopus 로고
    • Periodic heat flow-composite walls or roofs
    • Mackey C.O., and Wright L.T. Periodic heat flow-composite walls or roofs. ASHVE Trans 52 (1946) 283
    • (1946) ASHVE Trans , vol.52 , pp. 283
    • Mackey, C.O.1    Wright, L.T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.