메뉴 건너뛰기




Volumn 37, Issue 9, 2005, Pages 972-981

The dynamic thermal characteristics of lightweight building elements with a forced ventilated cavity and radiation barriers

Author keywords

Dynamic thermal characteristics; Lightweight building element; Two dimensional heat transfer; Ventilated cavity

Indexed keywords

HEAT FLUX; HEAT TRANSFER; RADIATION EFFECTS; TEMPERATURE DISTRIBUTION; THERMAL INSULATION; THERMOANALYSIS; VENTILATION;

EID: 23744445596     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2004.12.006     Document Type: Article
Times cited : (16)

References (14)
  • 3
    • 0342646947 scopus 로고    scopus 로고
    • Effects of shingle absorptivity, radiant barrier emissivity, attic ventilation flow rate and roof slope on the performance of radiant barriers
    • M.A. Medina Effects of shingle absorptivity, radiant barrier emissivity, attic ventilation flow rate and roof slope on the performance of radiant barriers International Journal of Energy Research 24 2000 665 678
    • (2000) International Journal of Energy Research , vol.24 , pp. 665-678
    • Medina, M.A.1
  • 4
    • 0034324940 scopus 로고    scopus 로고
    • On the performance of radiant barrier in combination with different attic insulation levels
    • M.A. Medina On the performance of radiant barrier in combination with different attic insulation levels Energy and Buildings 33 1 2000 31 40
    • (2000) Energy and Buildings , vol.33 , Issue.1 , pp. 31-40
    • Medina, M.A.1
  • 5
    • 0030260326 scopus 로고    scopus 로고
    • A quasi-steady-state model of attic heat transfer with radiant barriers
    • D.W. Winiarski, and D.L. O'Neal A quasi-steady-state model of attic heat transfer with radiant barriers Energy and Buildings 24 3 1996 183 194
    • (1996) Energy and Buildings , vol.24 , Issue.3 , pp. 183-194
    • Winiarski, D.W.1    O'Neal, D.L.2
  • 7
    • 0026406925 scopus 로고
    • A multicomponent PCM wall optimized for passive solar heating
    • K. Peippo, P. Kauranen, and P.D. Lund A multicomponent PCM wall optimized for passive solar heating Energy and Buildings 17 4 1991 259 270
    • (1991) Energy and Buildings , vol.17 , Issue.4 , pp. 259-270
    • Peippo, K.1    Kauranen, P.2    Lund, P.D.3
  • 8
    • 0031236578 scopus 로고    scopus 로고
    • Investigation of the thermal performance of a passive solar test-room with wall latent heat storage
    • A.K. Athienitis, C. Liu, D. Hawes, D. Banu, and D. Feldman Investigation of the thermal performance of a passive solar test-room with wall latent heat storage Building and Environment 32 5 1997 405 410
    • (1997) Building and Environment , vol.32 , Issue.5 , pp. 405-410
    • Athienitis, A.K.1    Liu, C.2    Hawes, D.3    Banu, D.4    Feldman, D.5
  • 13
    • 0242406164 scopus 로고    scopus 로고
    • A large-panel unglazed roof-integrated liquid solar collector - Energy and economic evaluation
    • S. Medved, C. Arkar, and B. Černe A large-panel unglazed roof-integrated liquid solar collector - energy and economic evaluation Solar Energy 75 6 2003 455 467
    • (2003) Solar Energy , vol.75 , Issue.6 , pp. 455-467
    • Medved, S.1    Arkar, C.2    Černe, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.