메뉴 건너뛰기




Volumn 102, Issue 8, 2009, Pages 867-869

Isopropyl alcohol ingestion presenting as pseudorenal failure due to acetone interference

Author keywords

Acetone interference; Acute renal failure; Colorimetric assay; Isopropyl alcohol

Indexed keywords

2 PROPANOL; 4 METHYLPYRAZOLE; ACETONE; CREATININE; OPIATE; SOLVENT;

EID: 68849094212     PISSN: 00384348     EISSN: None     Source Type: Journal    
DOI: 10.1097/SMJ.0b013e3181ac12f1     Document Type: Article
Times cited : (11)

References (11)
  • 1
    • 19044372385 scopus 로고    scopus 로고
    • Isopropyl alcohol intoxication: A diagnostic challenge
    • Zaman F, Pervez A, Abreo K. Isopropyl alcohol intoxication: a diagnostic challenge. Am J Kidney Dis 2002;40:E12.
    • (2002) Am J Kidney Dis , vol.40
    • Zaman, F.1    Pervez, A.2    Abreo, K.3
  • 2
    • 0033693494 scopus 로고    scopus 로고
    • Treatment of the alcohol intoxications: Ethylene glycol, methanol and isopropanol
    • DOI 10.1097/00041552-200011000-00017
    • Abramson S, Singh AK. Treatment of the alcohol intoxications: ethylene glycol, methanol and isopropanol. Curr Opin Nephrol Hypertens 2000; 9:695-701. (Pubitemid 30954347)
    • (2000) Current Opinion in Nephrology and Hypertension , vol.9 , Issue.6 , pp. 695-701
    • Abramson, S.1    Singh, A.K.2
  • 3
    • 33746393586 scopus 로고    scopus 로고
    • The poisoned patient with metabolic acidosis (a medical toxicologist's perspective)
    • White S. The poisoned patient with metabolic acidosis (a medical toxicologist's perspective). Midwest Assoc Toxicol Ther Drug Monit Newsl 2002;8:1.
    • (2002) Midwest Assoc Toxicol Ther Drug Monit Newsl , vol.8 , pp. 1
    • White, S.1
  • 5
    • 0019961969 scopus 로고
    • 'Pseudo' renal failure after isopropyl alcohol intoxication
    • Hawley PC, Falko JM. "Pseudo" renal failure after isopropyl alcohol intoxication. South Med J 1982;75:630-631. (Pubitemid 12060325)
    • (1982) Southern Medical Journal , vol.75 , Issue.5 , pp. 630-631
    • Hawley, P.C.1    Falko, J.M.2
  • 6
    • 33746415768 scopus 로고    scopus 로고
    • Isopropyl Alcohol-induced Pseudo-azotemia: Taking Advantage of a Laboratory Error
    • DOI 10.1016/j.amjmed.2005.12.024, PII S0002934306000313
    • Peng LW, Janga R, Lien YH. Isopropyl alcohol-induced pseudo-azotemia: taking advantage of a laboratory error. Am J Med 2006;119:e9. (Pubitemid 44128442)
    • (2006) American Journal of Medicine , vol.119 , Issue.8
    • Peng, L.W.1    Janga, R.2    Lien, Y.-H.H.3
  • 7
    • 0014150584 scopus 로고
    • The effect of ketone bodies on the determination of creatinine
    • Wakins PJ. The effect of ketone bodies on the determination of creatinine. Clin Chim Acta 1967;18:191-196.
    • (1967) Clin Chim Acta , vol.18 , pp. 191-196
    • Wakins, P.J.1
  • 8
    • 69549152860 scopus 로고
    • Glucose and acetone as sources of error in plasma creatinine determinations
    • Haugen HN. Glucose and acetone as sources of error in plasma creatinine determinations. Scand J Clin Lab Invest 1954;6:17-21.
    • (1954) Scand J Clin Lab Invest , vol.6 , pp. 17-21
    • Haugen, H.N.1
  • 9
    • 0031925339 scopus 로고    scopus 로고
    • False elevation of serum creatinine following skin absorption of nitromethane complicates the clinical diagnosis of rhabdomyolysis
    • Gabrielli A, Hammett-Stabler C. False elevation of serum creatinine following skin absorption of nitromethane complicates the clinical diagnosis of rhabdomyolysis. Chest 1998;113:1419-1422. (Pubitemid 28223841)
    • (1998) Chest , vol.113 , Issue.5 , pp. 1419-1422
    • Gabrielli, A.1    Hammett-Stabler, C.2
  • 10
    • 36349006181 scopus 로고    scopus 로고
    • Measurement of serum creatinine - Current status and future goals
    • Peake M, Whiting M. Measurement of serum creatinine - current status and future goals. Clin Biochem Rev 2006;27:173-184.
    • (2006) Clin Biochem Rev , vol.27 , pp. 173-184
    • Peake, M.1    Whiting, M.2
  • 11
    • 33745197542 scopus 로고    scopus 로고
    • Comparability of point-of-care whole-blood electrolyte and substrate testing using a Stat Profile Critical Care Xpress analyzer and standard laboratory methods
    • DOI 10.1515/CCLM.2006.148
    • Flegar-Mestrić Z, Perkov S. Comparibilty of point-of-care whole-blood electrolyte and substrate testing using a Stat Profile Critical Xpress analyzer and standard laboratory methods. Clin Chem Lab Med 2006; 44:898-903. (Pubitemid 43911568)
    • (2006) Clinical Chemistry and Laboratory Medicine , vol.44 , Issue.7 , pp. 898-903
    • Flegar-Mestric, Z.1    Perkov, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.