Volumn 44, Issue 7, 2006, Pages 898-903

Comparability of point-of-care whole-blood electrolyte and substrate testing using a Stat Profile Critical Care Xpress analyzer and standard laboratory methods

Author keywords

Analytical quality specification; Biosensor based analysis; Point of care testing

Indexed keywords

CHLORIDE; CREATININE; GLUCOSE; POTASSIUM; SODIUM; UREA;

EID: 33745197542     PISSN: 14346621     EISSN: 14346621     Source Type: Journal    
DOI: 10.1515/CCLM.2006.148     Document Type: Article
Times cited : (22)

References (24)
  • 1
    • 0027256177 scopus 로고
    • New whole blood analyzers and their impact on cardiac and critical care
    • Kost GJ. New whole blood analyzers and their impact on cardiac and critical care. Crit Rev Clin Lab Sci 1993;30:153-202.
    • (1993) Crit Rev Clin Lab Sci , vol.30 , pp. 153-202
    • Kost, G.J.1
  • 2
    • 0033852492 scopus 로고    scopus 로고
    • Multicenter study of whole-blood creatinine, total carbon dioxide content, and chemistry profiling for laboratory and point-of-care testing in critical care in the United States
    • Kost GJ, Vu H-T, Inn M, DuPlantier R, Fleisher M, Kroll MH, et al. Multicenter study of whole-blood creatinine, total carbon dioxide content, and chemistry profiling for laboratory and point-of-care testing in critical care in the United States. Crit Care Med 2000;28,7:2379-89.
    • (2000) Crit Care Med , vol.28 , Issue.7 , pp. 2379-2389
    • Kost, G.J.1    Vu, H.-T.2    Inn, M.3    Duplantier, R.4    Fleisher, M.5    Kroll, M.H.6
  • 3
    • 0035026066 scopus 로고    scopus 로고
    • Optimum analytical performance for point-of-care testing
    • Fraser CG. Optimum analytical performance for point-of-care testing. Clin Chim Acta 2001;307:37-43.
    • (2001) Clin Chim Acta , vol.307 , pp. 37-43
    • Fraser, C.G.1
  • 4
    • 33745194240 scopus 로고    scopus 로고
    • Quality control and quality assurance in point-of-care testing
    • Price CP, St John A, Hicks JM, editors. Washington, DC: AACC Press
    • Bullock DG. Quality control and quality assurance in point-of-care testing. In: Price CP, St John A, Hicks JM, editors. Point-of-care testing, 2nd ed. Washington, DC: AACC Press, 2004:137-45.
    • (2004) Point-of-care Testing, 2nd Ed. , pp. 137-145
    • Bullock, D.G.1
  • 5
  • 7
    • 0003491258 scopus 로고    scopus 로고
    • ISO 9001:2000. Geneva: International Organization for Standardization
    • ISO 9001:2000. Quality management system - requirements. Geneva: International Organization for Standardization, 2000.
    • (2000) Quality Management System - Requirements
  • 8
    • 0021045350 scopus 로고
    • A new biometrical procedure for testing the quality of measurement from two different analytical methods. Part I
    • Passing H, Bablok W. A new biometrical procedure for testing the quality of measurement from two different analytical methods. Part I. J Clin Chem Clin Biochem 1983;21:709-20.
    • (1983) J Clin Chem Clin Biochem , vol.21 , pp. 709-720
    • Passing, H.1    Bablok, W.2
  • 10
    • 0032695891 scopus 로고    scopus 로고
    • Recommendations of the German Working Group Medical Laboratory Testing (AML) on the introduction and quality assurance of procedures for point-of-care testing (POCT) in hospitals
    • Briedigkeit L, Müller-Plathe O, Schlebusch H, Ziems J. Recommendations of the German Working Group Medical Laboratory Testing (AML) on the introduction and quality assurance of procedures for point-of-care testing (POCT) in hospitals. Clin Chem Lab Med 1999;37:919-25.
    • (1999) Clin Chem Lab Med , vol.37 , pp. 919-925
    • Briedigkeit, L.1    Müller-Plathe, O.2    Schlebusch, H.3    Ziems, J.4
  • 11
    • 0031949146 scopus 로고    scopus 로고
    • The use of a whole-blood benchtop analyzer (Nova 16) in a cardiac stat intensive care unit
    • Kampa IS, Keffer P. The use of a whole-blood benchtop analyzer (Nova 16) in a cardiac stat intensive care unit. Clin Chem 1998;44:884-5.
    • (1998) Clin Chem , vol.44 , pp. 884-885
    • Kampa, I.S.1    Keffer, P.2
  • 13
    • 0033646159 scopus 로고    scopus 로고
    • Recommendations for measurement of and conventions for reporting sodium and potassium by ion-selective electrodes in undiluted serum, plasma or whole blood
    • Burnett RW, Covington AK, Fogh-Andersen N, Külpmann WR, Levenstam A, Maas AH, et al. Recommendations for measurement of and conventions for reporting sodium and potassium by ion-selective electrodes in undiluted serum, plasma or whole blood. Clin Chem Lab Med 2000;38:1065-71.
    • (2000) Clin Chem Lab Med , vol.38 , pp. 1065-1071
    • Burnett, R.W.1    Covington, A.K.2    Fogh-Andersen, N.3    Külpmann, W.R.4    Levenstam, A.5    Maas, A.H.6
  • 14
    • 0033920738 scopus 로고    scopus 로고
    • Use of ion-selective electrodes for blood-electrolyte analysis. Recommendation for nomenclature, definitions and conventions
    • Burnett RW, Covington AK, Fogh-Andersen N, Külpmann WR, Levenstam A, Maas AH, et al. Use of ion-selective electrodes for blood-electrolyte analysis. Recommendation for nomenclature, definitions and conventions. Clin Chem Lab Med 2000;38:363-70.
    • (2000) Clin Chem Lab Med , vol.38 , pp. 363-370
    • Burnett, R.W.1    Covington, A.K.2    Fogh-Andersen, N.3    Külpmann, W.R.4    Levenstam, A.5    Maas, A.H.6
  • 15
    • 0035038419 scopus 로고    scopus 로고
    • Reference ranges of electrolyte and anion gap on the Beckman E4A, Beckman Synchron CX5, Nova CRT, and Nova Stat Profile Ultra
    • Lolekha PH, Vanavanan S, Teerakarnjana N, Chaichanajarernkul U. Reference ranges of electrolyte and anion gap on the Beckman E4A, Beckman Synchron CX5, Nova CRT, and Nova Stat Profile Ultra. Clin Chim Acta 2001;307:87-93.
    • (2001) Clin Chim Acta , vol.307 , pp. 87-93
    • Lolekha, P.H.1    Vanavanan, S.2    Teerakarnjana, N.3    Chaichanajarernkul, U.4
  • 17
    • 33745197651 scopus 로고
    • Chemistry reference intervals for serum and plasma for the Beckman Synchron CX7 system utilizing the NCCLS C28-P guideline
    • Sasse E, Bartell C, Durl M, Patsches M. Chemistry reference intervals for serum and plasma for the Beckman Synchron CX7 system utilizing the NCCLS C28-P guideline. Clin Chem 1995;41:S199.
    • (1995) Clin Chem , vol.41
    • Sasse, E.1    Bartell, C.2    Durl, M.3    Patsches, M.4
  • 18
    • 33745186572 scopus 로고    scopus 로고
    • Brønshøj: Radiometer Medical A/S
    • Radiometer Medical. The blood gas handbook. Brønshøj: Radiometer Medical A/S, 2000.
    • (2000) The Blood Gas Handbook
  • 19
    • 24144476274 scopus 로고    scopus 로고
    • Measurement of circulating glucose concentrations: The time is now for consistency among methods and types of samples
    • Steffes MW. Measurement of circulating glucose concentrations: the time is now for consistency among methods and types of samples. Clin Chem 2005;51:1569-70.
    • (2005) Clin Chem , vol.51 , pp. 1569-1570
    • Steffes, M.W.1
  • 20
    • 0031937316 scopus 로고    scopus 로고
    • Proposal for standardizing direct-reading biosensors for blood glucose
    • Fogh-Anderson N, D'Orazio P. Proposal for standardizing direct-reading biosensors for blood glucose. Clin Chem 1998;44:655-9.
    • (1998) Clin Chem , vol.44 , pp. 655-659
    • Fogh-Anderson, N.1    D'Orazio, P.2
  • 22
    • 0036177713 scopus 로고    scopus 로고
    • Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus
    • Sacks DB, Bruns DE, Goldstein DE, Maclaren NK, McDonald JM, Parrott M. Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Clin Chem 2002;48:436-72.
    • (2002) Clin Chem , vol.48 , pp. 436-472
    • Sacks, D.B.1    Bruns, D.E.2    Goldstein, D.E.3    Maclaren, N.K.4    McDonald, J.M.5    Parrott, M.6
  • 23
    • 0024585018 scopus 로고
    • Differences between values for plasma and serum in tests performed in the Ektachem 700 XR analyzer, and evaluation of "plasma separator tube (PTS)"
    • Doumas BT, Hause LL, Simuncak DM, Breitenfeld D. Differences between values for plasma and serum in tests performed in the Ektachem 700 XR analyzer, and evaluation of "plasma separator tube (PTS)". Clin Chem 1989;35:151-3.
    • (1989) Clin Chem , vol.35 , pp. 151-153
    • Doumas, B.T.1    Hause, L.L.2    Simuncak, D.M.3    Breitenfeld, D.4
  • 24
    • 0024694007 scopus 로고
    • Serum and plasma compared for use in 19 common chemical tests performed in the Hitachi 737 analyzer
    • Ciuti R, Rinaldi G. Serum and plasma compared for use in 19 common chemical tests performed in the Hitachi 737 analyzer [letter]. Clin Chem 1989;35:1562-3.
    • (1989) Clin Chem , vol.35 , pp. 1562-1563
    • Ciuti, R.1    Rinaldi, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.