메뉴 건너뛰기




Volumn 37, Issue 9, 2009, Pages 1877-1885

Motion compensation in hand-held laser scanning for surface modeling in plastic and reconstructive surgery

Author keywords

Anatomical surface modeling; Breast surface analysis; Breathing artifact compensation; Plastic and reconstructive surgery

Indexed keywords

ACTIVE COMPENSATION; ANATOMICAL SURFACE MODELING; BIOMEDICAL IMAGING APPLICATIONS; BREAST SURFACE ANALYSIS; BREATHING ARTIFACT COMPENSATION; BREATHING MOTIONS; CLINICAL EVALUATION; INTEGRATED METHODOLOGY; INVOLUNTARY MOVEMENTS; LASER SCANNING; RECONSTRUCTIVE SURGERY; RESPIRATORY GATINGS; SURFACE DESCRIPTION; SURFACE MODELING; SURFACE MOTIONS;

EID: 68749094986     PISSN: 00906964     EISSN: 15739686     Source Type: Journal    
DOI: 10.1007/s10439-009-9752-8     Document Type: Article
Times cited : (18)

References (23)
  • 1
    • 44449121918 scopus 로고    scopus 로고
    • Prospective analysis of long-term psychosocial outcomes in breast reconstruction: Two-year postoperative results from the Michigan Breast Reconstruction Outcomes Study
    • D Atisha AK Alderman JC Lowery LE Kuhn J Davis EG Wilkins 2008 Prospective analysis of long-term psychosocial outcomes in breast reconstruction: two-year postoperative results from the Michigan Breast Reconstruction Outcomes Study Ann. Surg. 247 1019 1028
    • (2008) Ann. Surg. , vol.247 , pp. 1019-1028
    • Atisha, D.1    Alderman, A.K.2    Lowery, J.C.3    Kuhn, L.E.4    Davis, J.5    Wilkins, E.G.6
  • 2
    • 0029866986 scopus 로고    scopus 로고
    • Optoelectronic techniques for patient repositioning in radiotherapy
    • G Baroni G Ferrigno A Pedotti 1996 Optoelectronic techniques for patient repositioning in radiotherapy Technol. Health Care 3 251 262
    • (1996) Technol. Health Care , vol.3 , pp. 251-262
    • Baroni, G.1    Ferrigno, G.2    Pedotti, A.3
  • 3
    • 0033752825 scopus 로고    scopus 로고
    • Real-time opto-electronic verification of patient position in breast cancer radiotherapy
    • G Baroni G Ferrigno R Orecchia A Pedotti 2000 Real-time opto-electronic verification of patient position in breast cancer radiotherapy Comput. Aided Surg. 5 296 306
    • (2000) Comput. Aided Surg. , vol.5 , pp. 296-306
    • Baroni, G.1    Ferrigno, G.2    Orecchia, R.3    Pedotti, A.4
  • 4
    • 0033955778 scopus 로고    scopus 로고
    • Real-time three-dimensional motion analysis for patient positioning verification
    • G Baroni G Ferrigno R Orecchia A Pedotti 2000 Real-time three-dimensional motion analysis for patient positioning verification Radiother. Oncol. 54 21 27
    • (2000) Radiother. Oncol. , vol.54 , pp. 21-27
    • Baroni, G.1    Ferrigno, G.2    Orecchia, R.3    Pedotti, A.4
  • 13
  • 14
    • 33646113188 scopus 로고    scopus 로고
    • Quantitative analysis of the reconstructed breast using a 3-dimensional laser light scanner
    • N Isogai K Sai H Kamiishi M Watatani H Inui H Shiozaki 2006 Quantitative analysis of the reconstructed breast using a 3-dimensional laser light scanner Ann. Plast. Surg. 56 237 242
    • (2006) Ann. Plast. Surg. , vol.56 , pp. 237-242
    • Isogai, N.1    Sai, K.2    Kamiishi, H.3    Watatani, M.4    Inui, H.5    Shiozaki, H.6
  • 16
    • 0033227777 scopus 로고    scopus 로고
    • Breast reconstruction with TRAM flaps: Normal and abnormal appearances at CT
    • MA LePage EA Kazerooni MA Helvie EG Wilkins 1999 Breast reconstruction with TRAM flaps: normal and abnormal appearances at CT Radiographics 19 1593 1603
    • (1999) Radiographics , vol.19 , pp. 1593-1603
    • Lepage, M.A.1    Kazerooni, E.A.2    Helvie, M.A.3    Wilkins, E.G.4
  • 17
    • 29244455310 scopus 로고    scopus 로고
    • An objective evaluation of breast symmetry and shape differences using 3-dimensional images
    • A Losken I Fishman DD Denson HR Moyer GW Carlson 2005 An objective evaluation of breast symmetry and shape differences using 3-dimensional images Ann. Plast. Surg. 55 571 575
    • (2005) Ann. Plast. Surg. , vol.55 , pp. 571-575
    • Losken, A.1    Fishman, I.2    Denson, D.D.3    Moyer, H.R.4    Carlson, G.W.5
  • 21
    • 0025015710 scopus 로고
    • Immediate transposition of a latissimus dorsi muscle for correcting a postquadrantectomy breast deformity in Japanese patients
    • M Noguchi T Taniya I Miyazaki Y Saito 1990 Immediate transposition of a latissimus dorsi muscle for correcting a postquadrantectomy breast deformity in Japanese patients Int. Surg. 75 166 170
    • (1990) Int. Surg. , vol.75 , pp. 166-170
    • Noguchi, M.1    Taniya, T.2    Miyazaki, I.3    Saito, Y.4
  • 22
    • 0343775721 scopus 로고    scopus 로고
    • Practical do-it-yourself device for accurate volume measurement of breast
    • E Tezel A Numanoǧlu 2000 Practical do-it-yourself device for accurate volume measurement of breast Plast. Reconstr. Surg. 105 1019 1023
    • (2000) Plast. Reconstr. Surg. , vol.105 , pp. 1019-1023
    • Tezel, E.1    Numanoǧlu, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.