1
-
-
0034298196
-
Degradation of insulating materials under electrical stress
-
Mayoux, C.: ' Degradation of insulating materials under electrical stress ', IEEE Trans. Dielectr. Electric. Insulat., 2000, 7, (5), p. 590-601
-
(2000)
IEEE Trans. Dielectr. Electric. Insulat.
, vol.7
, Issue.5
, pp. 590-601
-
-
Mayoux, C.1
-
2
-
-
0346076735
-
Aging of oil-impregnated paper in power transformers
-
10.1109/TPWRD.2003.820175 0885-8977
-
Lundgaard, L.E., Hansen, W., Linhjell, D., and Painter, T.J.: ' Aging of oil-impregnated paper in power transformers ', IEEE Trans. Power Deliv., 2004, 19, (1), p. 230-239 10.1109/TPWRD.2003.820175 0885-8977
-
(2004)
IEEE Trans. Power Deliv.
, vol.19
, Issue.1
, pp. 230-239
-
-
Lundgaard, L.E.1
Hansen, W.2
Linhjell, D.3
Painter, T.J.4
-
3
-
-
18444391220
-
Variation of dielectric strength of an insulation paper with thermal aging
-
10.1016/j.ndteint.2004.12.006 0963-8695
-
Joshi, A., and Kumar, S.: ' Variation of dielectric strength of an insulation paper with thermal aging ', NDT&E Int., 2005, 38, (6), p. 459-461 10.1016/j.ndteint.2004.12.006 0963-8695
-
(2005)
NDT&E Int.
, vol.38
, Issue.6
, pp. 459-461
-
-
Joshi, A.1
Kumar, S.2
-
4
-
-
17644395307
-
Aging of cellulose at transformer service temperatures. Part 1: Influence of type of oil and air on the degree of polymerization of pressboard, dissolved gases, and furanic compounds in oil
-
DOI 10.1109/MEI.2005.1412215
-
Kachler, J., and Hohlein, I.: ' Aging of cellulose at transformer service temperatures. Part 1: Influence of type of oil and air on the degree of polymerization of pressboard, dissolved gases, and furanic compounds in oil ', IEEE Electr. Insul. Mag., 2005, 21, (2), p. 15-21 10.1109/MEI.2005.1412215 0883-7554 (Pubitemid 40556197)
-
(2005)
IEEE Electrical Insulation Magazine
, vol.21
, Issue.2
, pp. 15-21
-
-
Kachler, A.J.1
Hohlein, I.2
-
5
-
-
43649095180
-
Thermal aging studies on cellulose insulation paper of power transformer using AFM
-
' '
-
Ruijin, L., Chao, T., Lijun, Y., and Huanchao, C.: ' Thermal aging studies on cellulose insulation paper of power transformer using AFM ', 2006 Eighth Int. Conf. Properties and Applications of Dielectric Materials, 2006, p. 722-725
-
(2006)
2006 Eighth Int. Conf. Properties and Applications of Dielectric Materials
, pp. 722-725
-
-
Ruijin, L.1
Chao, T.2
Lijun, Y.3
Huanchao, C.4
-
6
-
-
34250315349
-
Time evolution of current through insulating paper under DC voltage stress
-
1070-9878
-
Bitam-Megherbi, F., and Megherbi, M.: ' Time evolution of current through insulating paper under DC voltage stress ', IEEE Trans. Dielectr. Electr. Insul., 2007, 14, (3), p. 656-662 1070-9878
-
(2007)
IEEE Trans. Dielectr. Electr. Insul.
, vol.14
, Issue.3
, pp. 656-662
-
-
Bitam-Megherbi, F.1
Megherbi, M.2
-
7
-
-
0037915585
-
The effect of metals on transformer oils and some methods of protection against adverse effect
-
' '
-
Wood-Mallock, J.C., and Wood, L.G.: ' The effect of metals on transformer oils and some methods of protection against adverse effect ', J. Inst. Pet., 1958, 44, p. 320-333
-
(1958)
J. Inst. Pet.
, vol.44
, pp. 320-333
-
-
Wood-Mallock, J.C.1
Wood, L.G.2
-
8
-
-
0036647275
-
Challenge of mixed insulating liquids for use in high-voltage transformers, Part 2: Investigations of mixed liquid impregnated paper insulation
-
DOI 10.1109/MEI.2002.1019901
-
Fofana, I., Wasserberg, V., Borsi, H., and Gockenbach, E.: ' Challenge of mixed insulating liquids for use in high-voltage transformers. II. Investigations of mixed liquid impregnated paper insulation ', IEEE Electr. Insul. Mag., 2002, 18, (4), p. 5-16 10.1109/MEI.2002.1019901 0883-7554 (Pubitemid 34822316)
-
(2002)
IEEE Electrical Insulation Magazine
, vol.18
, Issue.4
, pp. 5-16
-
-
Fofana, I.1
Wasserberg, V.2
Borsi, H.3
Gockenbach, E.4
-
9
-
-
0035273456
-
Retrofilling conditions of high voltage transformers
-
0883-7554
-
Fofana, I., Wasserberg, V., Borsi, H., and Gockenbach, E.: ' Retrofilling conditions of high voltage transformers ', IEEE Electr. Insul. Mag., 17, (2), p. 17-30 0883-7554
-
IEEE Electr. Insul. Mag.
, vol.17
, Issue.2
, pp. 17-30
-
-
Fofana, I.1
Wasserberg, V.2
Borsi, H.3
Gockenbach, E.4
-
10
-
-
0035680382
-
Aging of paper insulation in natural ester dielectric fluid
-
McShane, C.P., Rapp, K.J., Corkran, J.L., Gauger, G.A., and Luksich, J.: ' Aging of paper insulation in natural ester dielectric fluid ', 2001 IEEE/PES Transmission and Distribution Conf. and Exposition, 2001, 2, p. 675-679 (Pubitemid 34064057)
-
(2001)
Proceedings of the IEEE Power Engineering Society Transmission and Distribution Conference
, vol.2
, pp. 675-679
-
-
McShane, C.P.1
Rapp, K.J.2
Corkran, J.L.3
Gauger, G.A.4
Luksich, J.5
-
11
-
-
0024768426
-
Dissolved gas analysis: It can save your transformer
-
DOI 10.1109/57.44605
-
Duval, M.: ' Dissolved gas analysis: it can save your transformer ', IEEE Electr. Insul. Mag., 1989, 5, (6), p. 22-27 10.1109/57.44605 0883-7554 (Pubitemid 20653449)
-
(1989)
IEEE Electrical Insulation Magazine
, vol.5
, Issue.6
, pp. 22-27
-
-
Duval, M.1
-
12
-
-
67649472911
-
Gas evolution from transformer insulating materials due to aging deterioration
-
()
-
Ishii, T., and Namba, S.: ' Gas evolution from transformer insulating materials due to aging deterioration ', Elec. Eng. (Japan), 1970, 90, (3), p. 53-55
-
(1970)
Elec. Eng. (Japan)
, vol.90
, Issue.3
, pp. 53-55
-
-
Ishii, T.1
Namba, S.2
-
13
-
-
67649458526
-
Composition of gases formed in electrical insulating oils
-
Davies, I.: ' Composition of gases formed in electrical insulating oils ', J. Appl. Chem. Biotechnol., 1971, 21, (10), p. 194-196
-
(1971)
J. Appl. Chem. Biotechnol.
, vol.21
, Issue.10
, pp. 194-196
-
-
Davies, I.1
-
15
-
-
0019665361
-
Cellulose insulation materials evaluated by degree of polymerization measurements
-
Chicago, IL, USA
-
Oomen, T.V., and Arnold, L.N.: ' Cellulose insulation materials evaluated by degree of polymerization measurements ', IEEE Proc. 15th Electrical Electronics Insul. Conf., Chicago, IL, USA, 1981, p. 257-261
-
(1981)
IEEE Proc. 15th Electrical Electronics Insul. Conf.
, pp. 257-261
-
-
Oomen, T.V.1
Arnold, L.N.2
-
16
-
-
17344389636
-
Application of cellulosic and non-cellulosic materials in power transformers
-
Paris, France
-
Moser, H., and Dahinden, V.: ' Application of cellulosic and non-cellulosic materials in power transformers ', Intern. Conf. Large High Voltage Electr. System, CIGRE Proc. 31st Session, Paris, France, 1986, p. 12
-
(1986)
Intern. Conf. Large High Voltage Electr. System, CIGRE Proc. 31st Session
, pp. 12
-
-
Moser, H.1
Dahinden, V.2
-
17
-
-
0026294405
-
Studies of the condition of insulation in aged power transformers. 1. Insulation condition and remnant life assessments for in-service units
-
Tokyo, Japan
-
Allan, D., Jones, C., and Sharp, B.: ' Studies of the condition of insulation in aged power transformers. 1. Insulation condition and remnant life assessments for in-service units ', IEEE Proc. third Int. Conf. Properties and Appl. Dielectr. Materials (ICPADM), Tokyo, Japan, 1991, p. 1116-1119
-
(1991)
IEEE Proc. Third Int. Conf. Properties and Appl. Dielectr. Materials (ICPADM)
, pp. 1116-1119
-
-
Allan, D.1
Jones, C.2
Sharp, B.3
-
18
-
-
0022148642
-
Review of paper aging in power transformers
-
0143-7046
-
Shroff, D.H., and Stannett, A.W.: ' Review of paper aging in power transformers ', IEE Proc. C. Gener. Transm. Distrib., 1985, 132, (6), p. 312-319 0143-7046
-
(1985)
IEE Proc. C. Gener. Transm. Distrib.
, vol.132
, Issue.6
, pp. 312-319
-
-
Shroff, D.H.1
Stannett, A.W.2
-
19
-
-
0030398833
-
Thermal aging study of insulating papers used in power transformers
-
Millbrae, CA, USA
-
Lessard, M.C., Nifterik, L.V., Masse, M., Penneau, J.F., and Grob, R.: ' Thermal aging study of insulating papers used in power transformers ', IEEE 1996 Annual Report of the Conf. Electrical Insulation and Dielectric Phenomena, Millbrae, CA, USA, 1996, p. 854-859
-
(1996)
IEEE 1996 Annual Report of the Conf. Electrical Insulation and Dielectric Phenomena
, pp. 854-859
-
-
Lessard, M.C.1
Nifterik, L.V.2
Masse, M.3
Penneau, J.F.4
Grob, R.5
-
20
-
-
0033742666
-
Degradation of cellulosic insulation in power Transformers. Part 2: Formation of furan products in insulating oil
-
10.1049/ip-smt:20000259 1350-2344
-
Emsley, M., Xiao, X., Heywood, R.J., and Ali, M.: ' Degradation of cellulosic insulation in power Transformers. Part 2: Formation of furan products in insulating oil ', IEE Proc. Sci. Meas. Technol., 2003, 147, (3), p. 110-114 10.1049/ip-smt:20000259 1350-2344
-
(2003)
IEE Proc. Sci. Meas. Technol.
, vol.147
, Issue.3
, pp. 110-114
-
-
Emsley, M.1
Xiao, X.2
Heywood, R.J.3
Ali, M.4
-
21
-
-
42149154837
-
Ageing of mineral oil impregnated cellulose by acid catalysis
-
DOI 10.1109/TDEI.2008.4483475, 4483475
-
Lundgaard, L.E., Hansen, W., and Ingebrigtsen, S.: ' Ageing of mineral oil impregnated cellulose by acid catalysis ', IEEE Trans. Dielectr. Electr. Insul., 2008, 15, (2), p. 540-546 10.1109/TDEI.2008.4483475 1070-9878 (Pubitemid 351540667)
-
(2008)
IEEE Transactions on Dielectrics and Electrical Insulation
, vol.15
, Issue.2
, pp. 540-546
-
-
Lundgaard, L.E.1
Hansen, W.2
Ingebrigtsen, S.3
-
22
-
-
28444458889
-
Aging of Kraft paper by acid catalyzed hydrolysis
-
Portugal, June
-
Lundgaard, L.E., Hansen, W., Ingebrigtsen, S., Linhjell, D., and Dahlund, M.: ' Aging of Kraft paper by acid catalyzed hydrolysis ', 2005 IEEE Int. Conf. Dielectric Liquids (ICDL 2005), Portugal, June, 2005, p. 381-384
-
(2005)
2005 IEEE Int. Conf. Dielectric Liquids (ICDL 2005)
, pp. 381-384
-
-
Lundgaard, L.E.1
Hansen, W.2
Ingebrigtsen, S.3
Linhjell, D.4
Dahlund, M.5
|