-
1
-
-
0001439034
-
Prolonged assisted circulation during and after cardiac or aortic surgery. Prolonged partial left ventricular bypass by means of intracorporeal circulation
-
Liotta, D, Hall, CW, Henly, A, Cooley, DA, Crawford, ES, Debakey, ME. Prolonged assisted circulation during and after cardiac or aortic surgery. Prolonged partial left ventricular bypass by means of intracorporeal circulation. Am J Cardiol 1963; 12: 399-405.
-
(1963)
Am J Cardiol
, vol.12
, pp. 399-405
-
-
Liotta, D.1
Hall, C.W.2
Henly, A.3
Cooley, D.A.4
Crawford, E.S.5
Debakey, M.E.6
-
2
-
-
20444418691
-
Thirty-five years of mechanical circulatory support at the Texas Heart Institute
-
Gemmato, C, Forrester, M, Myers, T, Frazier, O, Cooley, D. Thirty-five years of mechanical circulatory support at the Texas Heart Institute. Tex Heart Inst J 2005; 32: 168-177.
-
(2005)
Tex Heart Inst J
, vol.32
, pp. 168-177
-
-
Gemmato, C.1
Forrester, M.2
Myers, T.3
Frazier, O.4
Cooley, D.5
-
3
-
-
21244479772
-
Mechanical circulatory support devices in Japan: Current status and future directions
-
Takatani, S, Matsuda, H, Hanatani, A, et al. Mechanical circulatory support devices in Japan: Current status and future directions. J Artif Organs 2005; 8: 13-27.
-
(2005)
J Artif Organs
, vol.8
, pp. 13-27
-
-
Takatani, S.1
Matsuda, H.2
Hanatani, A.3
-
4
-
-
33646243597
-
Third-generation blood pumps with mechanical noncontact magnetic bearings
-
Hoshi, H, Shinshi, T, Takatani, S. Third-generation blood pumps with mechanical noncontact magnetic bearings. Artif Organs 2006; 30(5): 324-338.
-
(2006)
Artif Organs
, vol.30
, Issue.5
, pp. 324-338
-
-
Hoshi, H.1
Shinshi, T.2
Takatani, S.3
-
5
-
-
56449088083
-
Continuous-flow rotary left ventricular assist devices with "3rd generation" design
-
Pagani, F. Continuous-flow rotary left ventricular assist devices with "3rd generation" design. Semin Thorac Cardiovasc Surg 2008; 20: 255-263.
-
(2008)
Semin Thorac Cardiovasc Surg
, vol.20
, pp. 255-263
-
-
Pagani, F.1
-
6
-
-
12944281172
-
Terumo implantable left ventricular assist system: Results of long-term animal study
-
Nojiri, C, Kijima, T, Maekawa, J, et al. Terumo implantable left ventricular assist system: Results of long-term animal study. ASAIO 2000; 46(1): 117-122.
-
(2000)
ASAIO
, vol.46
, Issue.1
, pp. 117-122
-
-
Nojiri, C.1
Kijima, T.2
Maekawa, J.3
-
7
-
-
12844254339
-
Effect of pump flow mode of novel left ventricular assist device upon end organ perfusion in dogs with doxorubicin induced heart failure
-
Eya, K, Tuzun, E, Conger, J, et al. Effect of pump flow mode of novel left ventricular assist device upon end organ perfusion in dogs with doxorubicin induced heart failure. ASAIO 2005; 51(1): 41-49.
-
(2005)
ASAIO
, vol.51
, Issue.1
, pp. 41-49
-
-
Eya, K.1
Tuzun, E.2
Conger, J.3
-
8
-
-
68449098490
-
Initial human experience with the Terumo DuraHeart™: A magnetically levitated centrifugal left ventricular assist system
-
El-Banayosy, A, Arusoglu, L, Morsbuis, M, et al. Initial human experience with the Terumo DuraHeart™: A magnetically levitated centrifugal left ventricular assist system. J Heart Lung Transplant 2005; 24(2S): S57.
-
(2005)
J Heart Lung Transplant
, vol.24
, Issue.2 S
-
-
El-Banayosy, A.1
Arusoglu, L.2
Morsbuis, M.3
-
9
-
-
68449083026
-
Initial results of European multicenter clinical trial with the DuraHeart™ mag-lev centrifugal left ventricular assist device
-
Nojiri, C. Initial results of European multicenter clinical trial with the DuraHeart™ mag-lev centrifugal left ventricular assist device. J Cardiac Fail 2006; 12(8): S158.
-
(2006)
J Cardiac Fail
, vol.12
, Issue.8
-
-
Nojiri, C.1
-
10
-
-
33750566081
-
The Dura-Heart™ VAD, a magnetically levitated centrifugal pump: The University of Vienna bridge-to-transplant experience
-
Nishinaka, T, Schima, H, Roethy, W, et al. The Dura-Heart™ VAD, a magnetically levitated centrifugal pump: The University of Vienna bridge-to-transplant experience. Circ J 2006; 70: 1421-1425.
-
(2006)
Circ J
, vol.70
, pp. 1421-1425
-
-
Nishinaka, T.1
Schima, H.2
Roethy, W.3
-
11
-
-
68449093549
-
Clinical outcome of the European multicenter trial with the DuraHeart™ mag-lev centrifugal left ventricular assist system
-
El-Banayosy, A, Koerfer, R. Wieselthaler, G, Pavie, A. Clinical outcome of the European multicenter trial with the DuraHeart™ mag-lev centrifugal left ventricular assist system. J Heart Lung Transplant 2007; 26(2S): S253.
-
(2007)
J Heart Lung Transplant
, vol.26
, Issue.2 S
-
-
El-Banayosy, A.1
Koerfer, R.2
Wieselthaler, G.3
Pavie, A.4
-
12
-
-
68449090478
-
-
Terumo Heart Inc. Jackson Road, Ann Arbor, MI
-
Terumo Heart Inc. The DuraHeart LVAS Hospital Guide. 2007: 6180 Jackson Road, Ann Arbor, MI.
-
(2007)
The DuraHeart LVAS Hospital Guide
, pp. 6180
-
-
-
13
-
-
0037336460
-
Implantation of the Jarvik 2000 left ventricular assist device without the use of cardiopulmonary bypass
-
Frazier, O. Implantation of the Jarvik 2000 left ventricular assist device without the use of cardiopulmonary bypass. Ann Thorac Surg 2003; 75: 1028-1030.
-
(2003)
Ann Thorac Surg
, vol.75
, pp. 1028-1030
-
-
Frazier, O.1
-
14
-
-
34547425297
-
Off-pump insertion of continuous flow left ventricular assist devices
-
Selzman, C, Sheridan, B. Off-pump insertion of continuous flow left ventricular assist devices. J Card Surg 2007; 22: 320-322.
-
(2007)
J Card Surg
, vol.22
, pp. 320-322
-
-
Selzman, C.1
Sheridan, B.2
-
15
-
-
34548686840
-
Off-pump implant of the Jarvik 2000 ventricular assist device through median sternotomy
-
Anyanwu, AC, Fischer, GW, Plotkina, I, Pinney, S, Adams, DH. Off-pump implant of the Jarvik 2000 ventricular assist device through median sternotomy. Ann Thorac Surg 2007; 84(4): 1405-1407.
-
(2007)
Ann Thorac Surg
, vol.84
, Issue.4
, pp. 1405-1407
-
-
Anyanwu, A.C.1
Fischer, G.W.2
Plotkina, I.3
Pinney, S.4
Adams, D.H.5
-
16
-
-
34249011417
-
Design features, developmental status, and experimental results with the HeartMate III centrifugal left ventricular assist system with a magnetically levitated rotor
-
Farrar, D, Bourque, K, Dague, C, Cotter, C, Poirier, V. Design features, developmental status, and experimental results with the HeartMate III centrifugal left ventricular assist system with a magnetically levitated rotor. ASAIO Journal 2007; 53: 310-315.
-
(2007)
ASAIO Journal
, vol.53
, pp. 310-315
-
-
Farrar, D.1
Bourque, K.2
Dague, C.3
Cotter, C.4
Poirier, V.5
|