메뉴 건너뛰기




Volumn 8, Issue 1, 2005, Pages 13-27

Mechanical circulatory support devices (MCSD) in Japan: Current status and future directions

Author keywords

Biventricular bypass device (BVAD); Mechanical circulatory support device (MCSD); Replacement device; Total artificial heart (TAH); Ventricular assist device (VAD)

Indexed keywords

ARTICLE; ASSISTED CIRCULATION; BIOCOMPATIBILITY; BLOOD FLOW; CLINICAL TRIAL; CONGESTIVE CARDIOMYOPATHY; CONVALESCENCE; DISEASE SEVERITY; GOVERNMENT; HUMAN; INDUSTRY; JAPAN; MATERIAL COATING; MEDICAL INSTRUMENTATION; MEDICAL TECHNOLOGY; NONHUMAN; PRIORITY JOURNAL; QUALITY OF LIFE; RELIABILITY; SAFETY; THROMBUS; TRANSPLANTATION; TREATMENT OUTCOME;

EID: 21244479772     PISSN: 14347229     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10047-004-0284-6     Document Type: Article
Times cited : (31)

References (63)
  • 2
    • 21244495565 scopus 로고    scopus 로고
    • Japan Organ Transplant Network. Newsletter 7, 2003 (in Japanese)
    • Japan Organ Transplant Network. Newsletter 7, 2003 (in Japanese)
  • 6
    • 0021929189 scopus 로고
    • Successful treatment of profound left ventricular failure by automatic left ventricular assist system
    • H Takano Y Taenaka T Nakatani T Akutsu H Manabe 1985 Successful treatment of profound left ventricular failure by automatic left ventricular assist system World J Surg 9 78 88
    • (1985) World J Surg , vol.9 , pp. 78-88
    • Takano, H.1    Taenaka, Y.2    Nakatani, T.3    Akutsu, T.4    Manabe, H.5
  • 8
    • 21244459905 scopus 로고    scopus 로고
    • Patient implanted with a ventricular assist pump discharged home for the first time in Japan
    • Sept 7
    • Patient implanted with a ventricular assist pump discharged home for the first time in Japan. Asahi Evening Newspaper Report, Sept 7, 1996
    • (1996) Asahi Evening Newspaper Report
  • 16
    • 0034533832 scopus 로고    scopus 로고
    • Mechanical circulatory support devices for bridge to heart transplantation, bridge to recovery, or destination therapy
    • S Takatani T Sakamoto 2000 Mechanical circulatory support devices for bridge to heart transplantation, bridge to recovery, or destination therapy J Artif Organs 3 75
    • (2000) J Artif Organs , vol.3 , pp. 75
    • Takatani, S.1    Sakamoto, T.2
  • 17
    • 0038818918 scopus 로고    scopus 로고
    • Progress in ventricular assist systems (VAS) and treatment of pump failure
    • T Nakatani H Takano 2003 Progress in ventricular assist systems (VAS) and treatment of pump failure Nippon Rinsho 61 Suppl 5 472 477
    • (2003) Nippon Rinsho 61 Suppl , vol.5 , pp. 472-477
    • Nakatani, T.1    Takano, H.2
  • 19
    • 0030041698 scopus 로고    scopus 로고
    • Ventricular assist systems: Experience in Japan with Toyobo pump and Zeon pump
    • 1
    • H Takano T Nakatani 1996 Ventricular assist systems: experience in Japan with Toyobo pump and Zeon pump Ann Thorac Surg 61 1 317 322
    • (1996) Ann Thorac Surg , vol.61 , pp. 317-322
    • Takano, H.1    Nakatani, T.2
  • 20
    • 0034062868 scopus 로고    scopus 로고
    • Novacor left ventricular assist system versus HeartMate vented electric left ventricular assist system as a long-term mechanical circulatory support device in bridging patients: A prospective study
    • EL Banayosy L Arusoglu L Kizner G Tenderich K Minami K Inoue R Korfer 2000 Novacor left ventricular assist system versus HeartMate vented electric left ventricular assist system as a long-term mechanical circulatory support device in bridging patients: a prospective study J Thorac Cardiovasc Surg 119 581 587
    • (2000) J Thorac Cardiovasc Surg , vol.119 , pp. 581-587
    • Banayosy, E.L.1    Arusoglu, L.2    Kizner, L.3    Tenderich, G.4    Minami, K.5    Inoue, K.6    Korfer, R.7
  • 21
    • 0033931971 scopus 로고    scopus 로고
    • Morbidity and outcome after mechanical ventricular support using Thoratec, Novacor and HeartMate, for bridging to heart transplantation
    • K Minami EL Banayosy A Sezai L Anusoglu P Sarnowsky O Fey R Koerfer 2000 Morbidity and outcome after mechanical ventricular support using Thoratec, Novacor and HeartMate, for bridging to heart transplantation Artif Organs 24 421 426
    • (2000) Artif Organs , vol.24 , pp. 421-426
    • Minami, K.1    Banayosy, E.L.2    Sezai, A.3    Anusoglu, L.4    Sarnowsky, P.5    Fey, O.6    Koerfer, R.7
  • 22
    • 0035783884 scopus 로고    scopus 로고
    • HeartMate LVAS Investigators. Left ventricular assist system. Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation
    • OH Frazier EA Rose MC Oz W Dembitsky P McCarthy B Radovancevic VL Poirier KA Dasse 2001 HeartMate LVAS Investigators. Left ventricular assist system. Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation J Thorac Cardiovasc Surg 122 1186 1195
    • (2001) J Thorac Cardiovasc Surg , vol.122 , pp. 1186-1195
    • Frazier, O.H.1    Rose, E.A.2    Oz, M.C.3    Dembitsky, W.4    McCarthy, P.5    Radovancevic, B.6    Poirier, V.L.7    Dasse, K.A.8
  • 23
    • 0035138879 scopus 로고    scopus 로고
    • Improved outcomes with an implantable left ventricular assist system: A multicenter study
    • PM Portner PG Jansen PE Oyer DR Wheeldon N Ramasamy 2001 Improved outcomes with an implantable left ventricular assist system: a multicenter study Ann Thorac Surg 71 205 209
    • (2001) Ann Thorac Surg , vol.71 , pp. 205-209
    • Portner, P.M.1    Jansen, P.G.2    Oyer, P.E.3    Wheeldon, D.R.4    Ramasamy, N.5
  • 42
    • 0036035460 scopus 로고    scopus 로고
    • The fourth-generation centrifugal blood pump
    • S Ichikawa K Watanabe Y Nose 2002 The fourth-generation centrifugal blood pump J Artif Organs 5 208 210
    • (2002) J Artif Organs , vol.5 , pp. 208-210
    • Ichikawa, S.1    Watanabe, K.2    Nose, Y.3
  • 45
    • 2542492901 scopus 로고    scopus 로고
    • Flow visualization in a centrifugal blood pump with an eccentric inlet port
    • 6
    • T Yamane T Kodama Y Yamamoto T Shinohara Nose 2004 Flow visualization in a centrifugal blood pump with an eccentric inlet port Artif Organs 28 6 564 570
    • (2004) Artif Organs , vol.28 , pp. 564-570
    • Yamane, T.1    Kodama, T.2    Yamamoto, Y.3    Shinohara Nose, T.4
  • 49
    • 0027967449 scopus 로고
    • Chronic nonpulsatile blood flow: I. Cerebral autoregulation in chronic nonpulsatile biventricular bypass: Carotid blood flow response to hypercapnia
    • R Tominaga WA Smith A Massiello H Harasaki LA Golding 1994 Chronic nonpulsatile blood flow: I. Cerebral autoregulation in chronic nonpulsatile biventricular bypass: carotid blood flow response to hypercapnia J Thorac Cardiovasc Surg 108 907 912
    • (1994) J Thorac Cardiovasc Surg , vol.108 , pp. 907-912
    • Tominaga, R.1    Smith, W.A.2    Massiello, A.3    Harasaki, H.4    Golding, L.A.5
  • 50
    • 0029933188 scopus 로고    scopus 로고
    • Chronic nonpulsatile blood flow: II. Hemodynamic responses to progressive exercise in calves with chronic nonpulsatile biventricular bypass
    • R Tominaga WA Smith A Massiello H Harasaki LA Golding 1996 Chronic nonpulsatile blood flow: II. Hemodynamic responses to progressive exercise in calves with chronic nonpulsatile biventricular bypass J Thorac Cardiovasc Surg 111 857 862
    • (1996) J Thorac Cardiovasc Surg , vol.111 , pp. 857-862
    • Tominaga, R.1    Smith, W.A.2    Massiello, A.3    Harasaki, H.4    Golding, L.A.5
  • 51
    • 0029969366 scopus 로고    scopus 로고
    • Chronic nonpulsatile blood flow: III. Effects of pump flow rate on oxygen transport and utilization in chronic nonpulsatile biventricular bypass
    • R Tominaga WA Smith A Massiello H Harasaki LA Golding 1996 Chronic nonpulsatile blood flow: III. Effects of pump flow rate on oxygen transport and utilization in chronic nonpulsatile biventricular bypass J Thorac Cardiovasc Surg 111 863 872
    • (1996) J Thorac Cardiovasc Surg , vol.111 , pp. 863-872
    • Tominaga, R.1    Smith, W.A.2    Massiello, A.3    Harasaki, H.4    Golding, L.A.5
  • 52
    • 2542419343 scopus 로고    scopus 로고
    • Myths and truths of pulsatile and nonpulsatile perfusion during acute and chronic cardiac support
    • 5
    • A Undar 2004 Myths and truths of pulsatile and nonpulsatile perfusion during acute and chronic cardiac support Artif Organs 28 5 439 443
    • (2004) Artif Organs , vol.28 , pp. 439-443
    • Undar, A.1
  • 53
    • 0242552124 scopus 로고    scopus 로고
    • Energy equivalent pressure formula is for precise quantification of different perfusion models (Letter)
    • A Undar 2003 Energy equivalent pressure formula is for precise quantification of different perfusion models (Letter) Ann Thorac Surg 76 1777 1778
    • (2003) Ann Thorac Surg , vol.76 , pp. 1777-1778
    • Undar, A.1
  • 54
    • 1542614575 scopus 로고    scopus 로고
    • Use of the Flowmaker (Jarvik 2000) left ventricular assist device for destination therapy and bridging to transplantation
    • 1-3
    • OH Frazier NA Shah TJ Myers KD Robertson ID Gregoric R Delgado 2004 Use of the Flowmaker (Jarvik 2000) left ventricular assist device for destination therapy and bridging to transplantation Cardiology 101 1-3 111 116
    • (2004) Cardiology , vol.101 , pp. 111-116
    • Frazier, O.H.1    Shah, N.A.2    Myers, T.J.3    Robertson, K.D.4    Gregoric, I.D.5    Delgado, R.6
  • 56
    • 0042917714 scopus 로고    scopus 로고
    • Worldwide experience with the MicroMed DeBakey ventricular assist device as a bridge to transplantation
    • DJ Goldstein 2003 Worldwide experience with the MicroMed DeBakey ventricular assist device as a bridge to transplantation Circulation 108 II 272
    • (2003) Circulation , vol.108 , pp. 272
    • Goldstein, D.J.1
  • 60
    • 21244437104 scopus 로고    scopus 로고
    • The RELIANT (R_andomized E_valuation of the Novacor L_VAS I_n A_ N_on-T_ransplant Population) Clinical Trial compares leading LVAS devices. (www.worldheart.com/clinical_information/clinical_trials.cfm)
    • Clinical Trial Compares Leading LVAS Devices
  • 62
    • 1942468594 scopus 로고    scopus 로고
    • Creation of a diaphragm patch to facilitate placement of the AbioCor implantable replacement heart
    • 5
    • RD Dowling AS Ghaly LA Gray Jr 2004 Creation of a diaphragm patch to facilitate placement of the AbioCor implantable replacement heart Ann Thorac Surg 77 5 1849 1850
    • (2004) Ann Thorac Surg , vol.77 , pp. 1849-1850
    • Dowling, R.D.1    Ghaly, A.S.2    Gray Jr., L.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.