메뉴 건너뛰기




Volumn 2, Issue 2, 2009, Pages 183-188

Investigation on the optimal position for the quantification of hepatic perfusion by use of dynamic contrast-enhanced computed tomography in rats

Author keywords

Dual input single compartment model; Dynamic contrast enhanced CT; Hepatic perfusion; Supine and prone positions

Indexed keywords

ANIMAL EXPERIMENT; ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; INFERIOR CAVA VEIN; LIVER BLOOD FLOW; LIVER PERFUSION; MALE; NONHUMAN; PORTAL VEIN; POSITION EFFECT; PRIORITY JOURNAL; RAT;

EID: 68449086243     PISSN: 18650333     EISSN: None     Source Type: Journal    
DOI: 10.1007/s12194-009-0063-4     Document Type: Article
Times cited : (7)

References (19)
  • 1
    • 0034544721 scopus 로고    scopus 로고
    • Non-invasive quantification of hepatic perfusion with dynamic computed tomography and a dual input one-compartmental model
    • R Materne BE Van Beers AM Smith I Leconte J Jamart J-P Dehoux 2000 Non-invasive quantification of hepatic perfusion with dynamic computed tomography and a dual input one-compartmental model Clin Sci 99 517 525
    • (2000) Clin Sci , vol.99 , pp. 517-525
    • Materne, R.1    Van Beers, B.E.2    Smith, A.M.3    Leconte, I.4    Jamart, J.5    Dehoux, J.-P.6
  • 3
    • 0027226363 scopus 로고
    • Functional images of hepatic perfusion obtained with dynamic CT
    • KA Miles MP Hayball AK Dixon 1993 Functional images of hepatic perfusion obtained with dynamic CT Radiology 188 405 411
    • (1993) Radiology , vol.188 , pp. 405-411
    • Miles, K.A.1    Hayball, M.P.2    Dixon, A.K.3
  • 5
    • 0028920413 scopus 로고
    • Single photon emission computed tomography to determine effective hepatic blood flow and intrahepatic shunting
    • M Iwasa K Nakamura T Nakagawa S Watanabe H Katoh Y Kinosada 1995 Single photon emission computed tomography to determine effective hepatic blood flow and intrahepatic shunting Hepatology 21 359 365
    • (1995) Hepatology , vol.21 , pp. 359-365
    • Iwasa, M.1    Nakamura, K.2    Nakagawa, T.3    Watanabe, S.4    Katoh, H.5    Kinosada, Y.6
  • 6
    • 0035013197 scopus 로고    scopus 로고
    • Liver kinetics of glucose analogs measured in pigs by PET: Importance of dual-input blood sampling
    • OL Munk L Bass K Roelsgaard D Bender SB Hansen S Keiding 2001 Liver kinetics of glucose analogs measured in pigs by PET: importance of dual-input blood sampling J Nucl Med 42 795 801
    • (2001) J Nucl Med , vol.42 , pp. 795-801
    • Munk, O.L.1    Bass, L.2    Roelsgaard, K.3    Bender, D.4    Hansen, S.B.5    Keiding, S.6
  • 8
    • 53749098967 scopus 로고    scopus 로고
    • A quantitative method for estimating hepatic blood flow using a dual-input single-compartment model
    • S Miyazaki K Murase T Yoshikawa S Morimoto Y Ohno K Sugimura 2008 A quantitative method for estimating hepatic blood flow using a dual-input single-compartment model Br J Radiol 81 790 800
    • (2008) Br J Radiol , vol.81 , pp. 790-800
    • Miyazaki, S.1    Murase, K.2    Yoshikawa, T.3    Morimoto, S.4    Ohno, Y.5    Sugimura, K.6
  • 9
    • 0035144643 scopus 로고    scopus 로고
    • Early changes in hepatic perfusion caused by occult metastases in rats: Detection with quantitative CT
    • CA Cuenod I Leconte N Slauve A Resten C Dromain B Poulet 2001 Early changes in hepatic perfusion caused by occult metastases in rats: detection with quantitative CT Radiology 218 556 561
    • (2001) Radiology , vol.218 , pp. 556-561
    • Cuenod, C.A.1    Leconte, I.2    Slauve, N.3    Resten, A.4    Dromain, C.5    Poulet, B.6
  • 10
    • 39049175151 scopus 로고    scopus 로고
    • Hemodynamic changes with liver fibrosis measured by dynamic contrast-enhanced MRI in rat
    • H Kubo M Harada M Ishikawa H Nishitani 2006 Hemodynamic changes with liver fibrosis measured by dynamic contrast-enhanced MRI in rat Magn Reson Med Sci 5 65 71
    • (2006) Magn Reson Med Sci , vol.5 , pp. 65-71
    • Kubo, H.1    Harada, M.2    Ishikawa, M.3    Nishitani, H.4
  • 11
    • 0035037806 scopus 로고    scopus 로고
    • Determination of arterial input function using fuzzy clustering for quantification of cerebral blood flow with dynamic susceptibility contrast-enhanced MR imaging
    • DOI 10.1002/jmri.1111
    • K Murase K Kikuchi H Miki T Shimizu J Ikezoe 2001 Determination of arterial input function using fuzzy clustering for quantification of cerebral blood flow with dynamic susceptibility contrast-enhanced MR imaging J Magn Reson Imaging 13 797 806 (Pubitemid 32381860)
    • (2001) Journal of Magnetic Resonance Imaging , vol.13 , Issue.5 , pp. 797-806
    • Murase, K.1    Kikuchi, K.2    Miki, H.3    Shimizu, T.4    Ikezoe, J.5
  • 12
    • 34548259249 scopus 로고    scopus 로고
    • An efficient method for calculating kinetic parameters in a dual-input single-compartment model
    • K Murase S Miyazaki X Yang 2007 An efficient method for calculating kinetic parameters in a dual-input single-compartment model Br J Radiol 80 371 375
    • (2007) Br J Radiol , vol.80 , pp. 371-375
    • Murase, K.1    Miyazaki, S.2    Yang, X.3
  • 13
    • 58149252282 scopus 로고    scopus 로고
    • Error analysis of the quantification of hepatic perfusion using a dual-input single-compartment model
    • S Miyazaki Y Yamazaki K Murase 2008 Error analysis of the quantification of hepatic perfusion using a dual-input single-compartment model Phys Med Biol 53 5927 5946
    • (2008) Phys Med Biol , vol.53 , pp. 5927-5946
    • Miyazaki, S.1    Yamazaki, Y.2    Murase, K.3
  • 14
    • 0032900885 scopus 로고    scopus 로고
    • Regional blood flow, capillary permeability, and compartmental volumes: Measurement with dynamic CT - Initial experience
    • G Brix ML Bahner U Hoffmann A Horvath W Schreiber 1999 Regional blood flow, capillary permeability, and compartmental volumes: measurement with dynamic CT - initial experience Radiology 210 269 276
    • (1999) Radiology , vol.210 , pp. 269-276
    • Brix, G.1    Bahner, M.L.2    Hoffmann, U.3    Horvath, A.4    Schreiber, W.5
  • 15
    • 56749186065 scopus 로고    scopus 로고
    • A method for quantitative assessment of renal function using dynamic contrast-enhanced computed tomography: Evaluation of drug-induced nephrotoxicity in rats
    • K Murase A Tachibana Y Kusakabe R Matsuura S Miyazaki 2008 A method for quantitative assessment of renal function using dynamic contrast-enhanced computed tomography: evaluation of drug-induced nephrotoxicity in rats Med Phys 35 5768 5776
    • (2008) Med Phys , vol.35 , pp. 5768-5776
    • Murase, K.1    Tachibana, A.2    Kusakabe, Y.3    Matsuura, R.4    Miyazaki, S.5
  • 16
    • 1842428911 scopus 로고    scopus 로고
    • Efficient method for calculating kinetic parameters using T1-weighted dynamic contrast-enhanced magnetic resonance imaging
    • K Murase 2004 Efficient method for calculating kinetic parameters using T1-weighted dynamic contrast-enhanced magnetic resonance imaging Magn Reson Med 51 858 862
    • (2004) Magn Reson Med , vol.51 , pp. 858-862
    • Murase, K.1
  • 18
    • 17044408427 scopus 로고    scopus 로고
    • Physical hemodynamic interaction between portal venous and hepatic arterial blood flow in humans
    • H Sugimoto T Kaneko M Hirota S Inoue S Takeda A Nakao 2005 Physical hemodynamic interaction between portal venous and hepatic arterial blood flow in humans Liver Int 25 282 287
    • (2005) Liver Int , vol.25 , pp. 282-287
    • Sugimoto, H.1    Kaneko, T.2    Hirota, M.3    Inoue, S.4    Takeda, S.5    Nakao, A.6
  • 19
    • 8344262297 scopus 로고    scopus 로고
    • Early modifications of hepatic perfusion measured by functional CT in a rat model of hepatocellular carcinoma using a blood pool contrast agent
    • LS Fournier CA Cuenod C de Bazelaire N Siauve C Rosty PL Tran 2004 Early modifications of hepatic perfusion measured by functional CT in a rat model of hepatocellular carcinoma using a blood pool contrast agent Eur Radiol 14 2125 2133
    • (2004) Eur Radiol , vol.14 , pp. 2125-2133
    • Fournier, L.S.1    Cuenod, C.A.2    De Bazelaire, C.3    Siauve, N.4    Rosty, C.5    Tran, P.L.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.