메뉴 건너뛰기




Volumn 394, Issue 7, 2009, Pages 1947-1953

A microsystem of low-voltage-driven electrophoresis on microchip with array electrode pairs for the separation of amino acids

Author keywords

Electrophoresis driven by low voltage on microchip; Integrated circuit; Microelectrode array; Microelectromechanical systems technology; Separation of amino acids

Indexed keywords

ANALYTES; ARRAY-ELECTRODE; BIOCHEMICAL ANALYSIS; COVER PLATE; DC VOLTAGE; DIRECT CURRENT VOLTAGE; ELECTRIC FIELD STRENGTH; ELECTRODE PAIRS; LOW-VOLTAGE; MICRO ELECTRO MECHANICAL SYSTEM; MICROCHIP ELECTROPHORESIS; MICROELECTRODE ARRAY; MICROELECTROMECHANICAL SYSTEMS TECHNOLOGY; MICROFLUIDIC CHANNEL; MICROFLUIDIC ELECTROPHORESIS; NEW APPROACHES; POLYDIMETHYLSILOXANE PDMS; ROOM TEMPERATURE; SILICON-ON-INSULATOR SUBSTRATES; SOI WAFERS;

EID: 68349105787     PISSN: 16182642     EISSN: 16182650     Source Type: Journal    
DOI: 10.1007/s00216-009-2889-3     Document Type: Article
Times cited : (10)

References (14)
  • 1
    • 0025207507 scopus 로고
    • Miniaturized total chemical analysis systems: a novel concept for chemical sensing
    • A Manz N Graber HM Widmer 1990 Miniaturized total chemical analysis systems: a novel concept for chemical sensing Sens Actuators B1 244 248
    • (1990) Sens Actuators , vol.1 , pp. 244-248
    • Manz, A.1    Graber, N.2    Widmer, H.M.3
  • 2
    • 0037096666 scopus 로고    scopus 로고
    • Micro total analysis systems. 1. Introduction, theory, and technology
    • DOI 10.1021/ac0202435
    • DR Reyes D Iossifidis PA Auroux A Manz 2002 Micro total analysis systems 1, introduction, theory, and technology Anal Chem 74 2623 2636 (Pubitemid 34651165)
    • (2002) Analytical Chemistry , vol.74 , Issue.12 , pp. 2623-2636
    • Reyes, D.R.1    Iossifidis, D.2    Auroux, P.-A.3    Manz, A.4
  • 3
    • 0037096670 scopus 로고    scopus 로고
    • Micro total analysis systems. 2. Analytical standard operations and applications
    • DOI 10.1021/ac020239t
    • PA Auroux D Iossifidis DR Reyes A Manz 2002 Micro total analysis systems 2, analytical standard operations and applications Anal Chem 74 2637 2652 (Pubitemid 34651166)
    • (2002) Analytical Chemistry , vol.74 , Issue.12 , pp. 2637-2652
    • Auroux, P.-A.1    Iossifidis, D.2    Reyes, D.R.3    Manz, A.4
  • 4
    • 0034823594 scopus 로고    scopus 로고
    • Arrayed-electrode design for moving electric field driven capillary electrophoresis chips
    • Y-C Lin W-D Wu 2001 Arrayed-electrode design for moving electric field driven capillary electrophoresis chips Sens Actuators B 73 54 62
    • (2001) Sens Actuators B , vol.73 , pp. 54-62
    • Lin Y-C1    Wu W-D2
  • 5
    • 0035501564 scopus 로고    scopus 로고
    • Design of low voltage-driven capillary electrophoresis chips using moving electrical fields
    • Y-C Lin 2001 Design of low voltage-driven capillary electrophoresis chips using moving electrical fields Sens Actuators B 80 33 40
    • (2001) Sens Actuators B , vol.80 , pp. 33-40
    • Lin Y-C1
  • 7
    • 68349117643 scopus 로고    scopus 로고
    • The simulation and analysis of fluidic field in low voltage CE microchip
    • X Yi W Zhi-yu L Xia R Feng H Xiao-guo 2007 The simulation and analysis of fluidic field in low voltage CE microchip Chin J Sens Actuators 20 1701 1705
    • (2007) Chin J Sens Actuators , vol.20 , pp. 1701-1705
    • Yi, X.1    Zhi-Yu, W.2    Xia, L.3    Feng, R.4    Xiao-Guo, H.5
  • 8
    • 34548186862 scopus 로고    scopus 로고
    • Characterization and analysis of channel surface property in arrayed electrodes contained silicon electrophoresis microchip
    • X Yi LV Jun-jiang D Hai S Ji-wei W Zhi-yu 2007 Characterization and analysis of channel surface property in arrayed electrodes contained silicon electrophoresis microchip Chin J Sens Actuators 20 6 1228 1233
    • (2007) Chin J Sens Actuators , vol.20 , Issue.6 , pp. 1228-1233
    • Yi, X.1    Jun-Jiang, L.V.2    Hai, D.3    Ji-Wei, S.4    Zhi-Yu, W.5
  • 9
    • 0346374842 scopus 로고    scopus 로고
    • Low-voltage driven control in electrophoresis microchips by traveling electric field
    • L-M Fu R-J Yang 2003 Low-voltage driven control in electrophoresis microchips by traveling electric field Electrophoresis 24 1253 1260
    • (2003) Electrophoresis , vol.24 , pp. 1253-1260
    • Fu L-M1    Yang R-J2
  • 10
    • 68349087267 scopus 로고    scopus 로고
    • Designing of capillary electrophoresis chips based on linear-arrayed electrode for μ-TAS
    • C Chao Z Zhan Z Bo-jun 2003 Designing of capillary electrophoresis chips based on linear-arrayed electrode for μ-TAS Chinese Micronanoelectronic Technology 7/8 362 368
    • (2003) Chinese Micronanoelectronic Technology , vol.78 , pp. 362-368
    • Chao, C.1    Zhan, Z.2    Bo-Jun, Z.3
  • 11
    • 68349111873 scopus 로고    scopus 로고
    • Capillary electrophoresis chip based on linear-arrayed electrode and single chip processor control system
    • C Chao Z Zhan 2004 Capillary electrophoresis chip based on linear-arrayed electrode and single chip processor control system Chinese Journal of Transducer Technology (J) 23 77 80
    • (2004) Chinese Journal of Transducer Technology (J) , vol.23 , pp. 77-80
    • Chao, C.1    Zhan, Z.2
  • 12
    • 68349109996 scopus 로고    scopus 로고
    • Biochip development and improvement based on electrophoresis separation
    • W Yi-zhong Z Zhan 2006 Biochip development and improvement based on electrophoresis separation Chinese Instrument Technique and Sensor 3 6 8
    • (2006) Chinese Instrument Technique and Sensor , vol.3 , pp. 6-8
    • Yi-Zhong, W.1    Zhan, Z.2
  • 13
    • 68349088440 scopus 로고    scopus 로고
    • The miniature control and detection system for electrophoresis chip based on micro controller
    • W Yi-zhong Z Zhan 2008 The miniature control and detection system for electrophoresis chip based on micro controller Chinese Microcomputer Applications 29 3 98 102
    • (2008) Chinese Microcomputer Applications , vol.29 , Issue.3 , pp. 98-102
    • Yi-Zhong, W.1    Zhan, Z.2
  • 14