메뉴 건너뛰기




Volumn 63, Issue 2, 2009, Pages 149-158

Distribution of silicone oil in prefilled glass syringes probed with optical and spectroscopic methods

Author keywords

Drug delivery device; Interference reflectometry; Prefilled glass syringe; Protein formulation; Raman microscope; Silicone oil; Zebra schlieren

Indexed keywords

SILICONE OIL; RECOMBINANT PROTEIN;

EID: 68349084595     PISSN: 10797440     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (31)

References (12)
  • 1
    • 0033744044 scopus 로고    scopus 로고
    • Current issues in manufacturing and control of sterile prefilled syringes
    • Karras L.; Wright, L.; Cox, L.; Kouns, T.; Akers, M. J. Current issues in manufacturing and control of sterile prefilled syringes. Pharm. Technol. 2000, 24, 188 193.
    • (2000) Pharm. Technol. , vol.24 , pp. 188-193
    • Karras, L.1    Wright, L.2    Cox, L.3    Kouns, T.4    Akers, M.J.5
  • 3
    • 34547177383 scopus 로고    scopus 로고
    • Patient acceptance of a novel electronic autoinjector device to administer recombinant human growth hormone: Results from an open-label, user survey of everyday use
    • Dahlgren, J.; Veimo, D.; Johansson, L.; Bech, I. Patient acceptance of a novel electronic autoinjector device to administer recombinant human growth hormone: results from an open-label, user survey of everyday use. Current Medical Research and Opinion 2007, 23, 1649-1655.
    • (2007) Current Medical Research and Opinion , vol.23 , pp. 1649-1655
    • Dahlgren, J.1    Veimo, D.2    Johansson, L.3    Bech, I.4
  • 4
    • 42349115064 scopus 로고    scopus 로고
    • Investigation of contaminants in protein pharmaceuticals in pre-filled syringes by multiple micro-spectroscopies
    • Wen, Z. Q.; Torraca, G.; Yee, C. Y.; Li, G. Investigation of contaminants in protein pharmaceuticals in pre-filled syringes by multiple micro-spectroscopies. Am. Pharm. Rev. 2007, 10, 101-107.
    • (2007) Am. Pharm. Rev. , vol.10 , pp. 101-107
    • Wen, Z.Q.1    Torraca, G.2    Yee, C.Y.3    Li, G.4
  • 5
    • 0023756187 scopus 로고
    • Contamination of insulin by silicone oil: A potential hazard of plastic insulin syringe
    • Baldwin, R. N. Contamination of insulin by silicone oil: a potential hazard of plastic insulin syringe. Diabet. Med. 1988, 5 (8), 789-790.
    • (1988) Diabet. Med. , vol.5 , Issue.8 , pp. 789-790
    • Baldwin, R.N.1
  • 6
    • 0024515587 scopus 로고
    • Silicone oil contamination of insulin
    • Chantelau E. Silicone oil contamination of insulin. Diabet. Med. 1989, 6, 278.
    • (1989) Diabet. Med. , vol.6 , pp. 278
    • Chantelau, E.1
  • 7
    • 17744363305 scopus 로고    scopus 로고
    • Silicone oil induced aggregation of proteins
    • Jones, L. S.; Kaufmann, A.; Middaugh, C. R. Silicone oil induced aggregation of proteins. J. Pharm. Sci. 2005, 94 (4), 918-927.
    • (2005) J. Pharm. Sci. , vol.94 , Issue.4 , pp. 918-927
    • Jones, L.S.1    Kaufmann, A.2    Middaugh, C.R.3
  • 8
    • 36849073223 scopus 로고    scopus 로고
    • Raman spectroscopy of protein pharmaceuticals
    • Wen, Z. Q. Raman spectroscopy of protein pharmaceuticals. J. Pharm. Sci. 2007, 96, 2861-2878.
    • (2007) J. Pharm. Sci. , vol.96 , pp. 2861-2878
    • Wen, Z.Q.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.