메뉴 건너뛰기




Volumn 43, Issue 4 PART 1, 1996, Pages 2199-2206

Investigation of the performance of the general electric advance positron emission tomograph in 3d mode

Author keywords

[No Author keywords available]

Indexed keywords

AXIAL RESOLUTION; COLSHER FILTER; DEAD TIME CORRECTION; LINE SPREAD FUNCTION; LINEAR INTERPOLATION; LINES OF RESPONSE; PHANTOMS; TRANSAXIAL RESOLUTION;

EID: 0030216794     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/23.531882     Document Type: Article
Times cited : (128)

References (15)
  • 3
    • 0024610693 scopus 로고    scopus 로고
    • 3D image reconstruction using all detected events. IEEE Trans. Nucl. Sci. 36(1): pp. 964-968., 1989
    • Kinahan P.E., Rogers J.G., Analytic 3D image reconstruction using all detected events. IEEE Trans. Nucl. Sci. 36(1): pp. 964-968., 1989
    • Rogers J.G., Analytic
    • Kinahan, P.E.1
  • 8
    • 33747343587 scopus 로고    scopus 로고
    • 15O bolus injection. Count rate performance and dose optimization., in Quantification of Brain Function using PET, C.V. Jones T., Myers R., Bailey D., Editor. 1995, Academic Press: San Diego. (In press).
    • 15O bolus injection. Count rate performance and dose optimization., in Quantification of Brain Function using PET, C.V. Jones T., Myers R., Bailey D., Editor. 1995, Academic Press: San Diego. (In press).
    • Law I., Paulson O
    • Holm, S.1
  • 11
    • 33747370555 scopus 로고    scopus 로고
    • 3D PET Using 2D Fitted Gaussian Functions. J. Nucl. Med. 36: p. 105P., 1995
    • Stearns C., Scatter Correction Method for 3D PET Using 2D Fitted Gaussian Functions. J. Nucl. Med. 36: p. 105P., 1995
    • Scatter Correction Method for
    • Stearns, C.1
  • 12
    • 0026582130 scopus 로고    scopus 로고
    • 3D Reconstruction Algorithm for Multi-Slice PET Scanners. Phys. Med. Biol. 37(3): pp 799-790, 1992.
    • Cherry SR, Dahlhom M, Hoffman FJ. Evaluation of a 3D Reconstruction Algorithm for Multi-Slice PET Scanners. Phys. Med. Biol. 37(3): pp 799-790, 1992.
    • Dahlhom M, Hoffman FJ. Evaluation of A
    • Cherry, S.R.1
  • 13
    • 0028348409 scopus 로고    scopus 로고
    • 3D Reconstruction Algorithms for Positron Emission Tomography. Phys. Med. Biol. 39(3): pp 305-320, 1994.
    • Defrise M, Geissbuchler A, Townsend DW. A Performance Study of 3D Reconstruction Algorithms for Positron Emission Tomography. Phys. Med. Biol. 39(3): pp 305-320, 1994.
    • Geissbuchler A, Townsend DW. A Performance Study of
    • Defrise, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.