메뉴 건너뛰기




Volumn 18, Issue 5, 2009, Pages 385-389

Influence of glaucomatous damage and optic disc size on glaucoma detection by scanning laser tomography

Author keywords

Glaucoma classification; Glaucomatous optic disc atrophy; Optic disc size; Scanning laser tomography

Indexed keywords

ADULT; AGED; ARTICLE; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DISEASE CLASSIFICATION; DISEASE REGISTRY; FEMALE; GLAUCOMA; HUMAN; INTRAOCULAR PRESSURE; MAJOR CLINICAL STUDY; MALE; OPTIC DISK; OPTICAL TOMOGRAPHY; PERIMETRY; PRIORITY JOURNAL; PROBABILITY; RECEIVER OPERATING CHARACTERISTIC; REGRESSION ANALYSIS; SCORING SYSTEM; STEREORADIOGRAPHY;

EID: 68249084347     PISSN: 10570829     EISSN: None     Source Type: Journal    
DOI: 10.1097/IJG.0b013e3181845ffd     Document Type: Article
Times cited : (11)

References (19)
  • 1
    • 68249115762 scopus 로고    scopus 로고
    • Glaucoma
    • Huang D, Kaiser PK, Lowder C, eds Philadelphia, PA: Mosby
    • Stein DM,Wollstein G, Schuman JS. Glaucoma. In: Huang D, Kaiser PK, Lowder C, eds. Retinal Imaging. Philadelphia, PA: Mosby; 2006.
    • (2006) Retinal Imaging
    • Stein, D.M.1    Wollstein, G.2    Schuman, J.S.3
  • 3
    • 40049084031 scopus 로고    scopus 로고
    • New developments in Heidelberg retina tomograph for glaucoma
    • DOI 10.1097/ICU.0b013e3282f4450b, PII 0005573520080300000011
    • Strouthidis NG, Garway-Heath DF. New developments in Heidelberg retina tomograph for glaucoma. Curr Opin Ophthalmol. 2008;19:141-148. (Pubitemid 351322817)
    • (2008) Current Opinion in Ophthalmology , vol.19 , Issue.2 , pp. 141-148
    • Strouthidis, N.G.1    Garway-Heath, D.F.2
  • 5
    • 0027586510 scopus 로고
    • Laser scanning tomography to diagnose and monitor glaucoma
    • Weinreb RN. Laser scanning tomography to diagnose and monitor glaucoma. Curr Opin Ophthalmol. 1993;4:3-6.
    • (1993) Curr Opin Ophthalmol , vol.4 , pp. 3-6
    • Weinreb, R.N.1
  • 6
    • 33846932611 scopus 로고    scopus 로고
    • The effects of study design and spectrum bias on the evaluation of diagnostic accuracy of confocal scanning laser ophthalmoscopy in glaucoma
    • DOI 10.1167/iovs.06-0618
    • Medeiros FA, Ng D, Zangwill LM, et al. The effects of study design and spectrum bias on the evaluation of diagnostic accuracy of confocal scanning laser ophthalmoscopy in glaucoma. Invest Ophthalmol Vis Sci. 2007;48:214-222. (Pubitemid 47251405)
    • (2007) Investigative Ophthalmology and Visual Science , vol.48 , Issue.1 , pp. 214-222
    • Medeiros, F.A.1    Ng, D.2    Zangwill, L.M.3    Sample, P.A.4    Bowd, C.5    Weinreb, R.N.6
  • 7
    • 0033653783 scopus 로고    scopus 로고
    • Identifying early glaucomatous changes: Comparison between expert clinical assessment of optic disc photographs and confocal scanning ophthalmoscopy
    • Wollstein G, Garway-Heath DF, Fontana L, et al. Identifying early glaucomatous changes: comparison between expert clinical assessment of optic disc photographs and confocal scanning ophthalmoscopy. Ophthalmology. 2000;107:2272-2277.
    • (2000) Ophthalmology , vol.107 , pp. 2272-2277
    • Wollstein, G.1    Garway-Heath, D.F.2    Fontana, L.3
  • 9
    • 68249095137 scopus 로고    scopus 로고
    • Ability of the Heidelberg retina tomograph to detect early glaucomatous visual field loss
    • Mikelberg FS, Parfitt CM, Swindale NV, et al. Ability of the Heidelberg retina tomograph to detect early glaucomatous visual field loss. J Glaucoma. 2002;19:197-207.
    • (2002) J Glaucoma , vol.19 , pp. 197-207
    • Mikelberg, F.S.1    Parfitt, C.M.2    Swindale, N.V.3
  • 11
    • 0020524559 scopus 로고
    • A method of comparing the areas under receiver operating characteristic curves derived from the same cases
    • Hanley JA, McNeil BJ. A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology. 1983;148:839-843.
    • (1983) Radiology , vol.148 , pp. 839-843
    • Hanley, J.A.1    McNeil, B.J.2
  • 12
    • 0031770658 scopus 로고    scopus 로고
    • Identification of early glaucoma cases with the scanning laser ophthalmoscope
    • DOI 10.1016/S0161-6420(98)98047-2
    • Wollstein G, Garway-Heath DF, Hitchings RA. Identification of early glaucoma cases with the scanning laser ophthalmoscope. Ophthalmology. 1998;105:1557-1563. (Pubitemid 28509784)
    • (1998) Ophthalmology , vol.105 , Issue.8 , pp. 1557-1563
    • Wollstein, G.1    Garway-Heath, D.F.2    Hitchings, R.A.3
  • 14
    • 0030985497 scopus 로고    scopus 로고
    • The effect of optic disc size on diagnostic precision with the Heidelberg Retina Tomograph
    • Iester M, Mikelberg FS, Drance SM. The effect of optic disc size on diagnostic precision with the Heidelberg retina tomograph. Ophthalmology. 1997;104:545-548. (Pubitemid 27120315)
    • (1997) Ophthalmology , vol.104 , Issue.3 , pp. 545-548
    • Iester, M.1    Mikelberg, F.S.2    Drance, S.M.3
  • 15
    • 0036369931 scopus 로고    scopus 로고
    • Imaging of the optic disc and retinal nerve fiber layer: The effects of age, optic disc area, refractive error, and gender
    • Bowd C, Zangwill LM, Blumenthal EZ, et al. Imaging of the optic disc and retinal nerve fiber layer: the effects of age, optic disc area, refractive error, and gender. J Opt Soc Am A Opt Image Sci Vis. 2002;19:197-207.
    • (2002) J Opt Soc Am a Opt Image Sci Vis , vol.19 , pp. 197-207
    • Bowd, C.1    Zangwill, L.M.2    Blumenthal, E.Z.3
  • 17
    • 0031979688 scopus 로고    scopus 로고
    • Detection of early glaucomatous structural damage with confocal scanning laser tomography
    • Bathija R, Zangwill LM, Berry CC, et al. Detection of early glaucomatous structural damage with confocal scanning laser tomography. J Glaucoma. 1998;7:121-127. (Pubitemid 28196100)
    • (1998) Journal of Glaucoma , vol.7 , Issue.2 , pp. 121-127
    • Bathija, R.1    Zangwill, L.2    Berry, C.C.3    Sample, P.A.4    Weinreb, R.N.5
  • 18
    • 0038321468 scopus 로고    scopus 로고
    • Comparison of data analysis tools for detection of glaucoma with the Heidelberg retina tomograph
    • DOI 10.1016/S0161-6420(03)00230-6
    • Ford BA, Artes PH, McCormick TA, et al. Comparison of data analysis tools for detection of glaucoma with the Heidelberg Retina Tomograph. Ophthalmology. 2003;110:1145-1150. (Pubitemid 36676646)
    • (2003) Ophthalmology , vol.110 , Issue.6 , pp. 1145-1150
    • Ford, B.A.1    Artes, P.H.2    McCormick, T.A.3    Nicolela, M.T.4    Leblanc, R.P.5    Chauhan, B.C.6
  • 19
    • 0031721225 scopus 로고    scopus 로고
    • Influence of optic disc size on the sensitivity of the heidelberg retina tomograph
    • DOI 10.1007/s004170050135
    • Mardin CY, Horn FK. Influence of optic disc size on the sensitivity of the Heidelberg Retina Tomograph. Graefes Arch Clin Exp Ophthalmol. 1998;236:641-645. (Pubitemid 28427173)
    • (1998) Graefe's Archive for Clinical and Experimental Ophthalmology , vol.236 , Issue.9 , pp. 641-645
    • Mardin, C.Y.1    Horn, F.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.