메뉴 건너뛰기




Volumn 22, Issue 5, 2009, Pages 376-383

Posterior pedicle fixation-based dynamic stabilization devices for the treatment of degenerative diseases of the lumbar spine

Author keywords

Degenerative disk disorders; Facet replacement; Lumbar spine; Motion preservation; Posterior dynamic stabilization

Indexed keywords

ARTICLE; HUMAN; INTERVERTEBRAL DISK DEGENERATION; LAMINECTOMY; LIGAMENT SURGERY; LOW BACK PAIN; LUMBAR SPINE; MEDICAL INSTRUMENTATION; ORTHOPEDIC EQUIPMENT; PEDICLE SCREW; PRIORITY JOURNAL; PSEUDARTHROSIS; SPINE DISEASE; SPINE FUSION; SPINE STABILIZATION; SPONDYLOLISTHESIS; TREATMENT INDICATION; TREATMENT OUTCOME; TREATMENT RESPONSE; VERTEBRAL CANAL STENOSIS;

EID: 68049104232     PISSN: 15360652     EISSN: None     Source Type: Journal    
DOI: 10.1097/BSD.0b013e31817c6489     Document Type: Article
Times cited : (79)

References (40)
  • 1
    • 1142310587 scopus 로고    scopus 로고
    • Critical analysis of trends in fusion for degenerative disc disease over the past 20 years: Influence of technique on fusion rate and clinical outcome
    • discussion Z5
    • Bono CM, Lee CK. Critical analysis of trends in fusion for degenerative disc disease over the past 20 years: influence of technique on fusion rate and clinical outcome. Spine. 2004;29:455-463; discussion Z5.
    • (2004) Spine , vol.29 , pp. 455-463
    • Bono, C.M.1    Lee, C.K.2
  • 3
    • 33846842325 scopus 로고    scopus 로고
    • Hybrid multidirectional test method to evaluate spinal adjacent-level effects
    • Panjabi MM. Hybrid multidirectional test method to evaluate spinal adjacent-level effects. Clin Biomech (Bristol, Avon). 2007;22:257-265.
    • (2007) Clin Biomech (Bristol, Avon) , vol.22 , pp. 257-265
    • Panjabi, M.M.1
  • 4
    • 0028043939 scopus 로고
    • Comparison of in vivo and in vitro adjacent segment motion after lumbar fusion
    • Dekutoski MB, Schendel MJ, Ogilvie JW, et al. Comparison of in vivo and in vitro adjacent segment motion after lumbar fusion. Spine. 1994;19:1745-1751.
    • (1994) Spine , vol.19 , pp. 1745-1751
    • Dekutoski, M.B.1    Schendel, M.J.2    Ogilvie, J.W.3
  • 5
    • 34548691444 scopus 로고    scopus 로고
    • Adjacent segment disease following lumbar/thoracolumbar fusion with pedicle screw instrumentation: A minimum 5-year follow-up
    • Cheh G, Bridwell KH, Lenke LG, et al. Adjacent segment disease following lumbar/thoracolumbar fusion with pedicle screw instrumentation: a minimum 5-year follow-up. Spine. 2007;32:2253-2257.
    • (2007) Spine , vol.32 , pp. 2253-2257
    • Cheh, G.1    Bridwell, K.H.2    Lenke, L.G.3
  • 6
    • 0036939771 scopus 로고    scopus 로고
    • Adjacent segment degeneration after lumbar spinal posterolateral fusion with instrumentation in elderly patients
    • Chou WY, Hsu CJ, Chang WN, et al. Adjacent segment degeneration after lumbar spinal posterolateral fusion with instrumentation in elderly patients. Arch Orthop Trauma Surg. 2002;122:39-43.
    • (2002) Arch Orthop Trauma Surg , vol.122 , pp. 39-43
    • Chou, W.Y.1    Hsu, C.J.2    Chang, W.N.3
  • 7
    • 23944453369 scopus 로고    scopus 로고
    • Dynamic stabilization in the surgical management of painful lumbar spinal disorders
    • Nockels RP. Dynamic stabilization in the surgical management of painful lumbar spinal disorders. Spine. 2005;30:S68-S72.
    • (2005) Spine , vol.30
    • Nockels, R.P.1
  • 8
    • 33644837768 scopus 로고    scopus 로고
    • Dynamic stabilization in addition to decompression for lumbar spinal stenosis with degenerative spondylolisthesis
    • Schnake KJ, Schaeren S, Jeanneret B. Dynamic stabilization in addition to decompression for lumbar spinal stenosis with degenerative spondylolisthesis. Spine. 2006;31:442-449.
    • (2006) Spine , vol.31 , pp. 442-449
    • Schnake, K.J.1    Schaeren, S.2    Jeanneret, B.3
  • 9
    • 33645324009 scopus 로고    scopus 로고
    • Dynamic stabilization devices in the treatment of low back pain
    • Sengupta DK. Dynamic stabilization devices in the treatment of low back pain. Neurol India. 2005;53:466-474.
    • (2005) Neurol India , vol.53 , pp. 466-474
    • Sengupta, D.K.1
  • 10
    • 33644837140 scopus 로고    scopus 로고
    • Point of view: Dynamic stabilization in addition to decompression for lumbar spinal stenosis with degenerative spondylolisthesis
    • Sengupta DK. Point of view: dynamic stabilization in addition to decompression for lumbar spinal stenosis with degenerative spondylolisthesis. Spine. 2006;31:450.
    • (2006) Spine , vol.31 , pp. 450
    • Sengupta, D.K.1
  • 11
    • 0042069550 scopus 로고    scopus 로고
    • Dynamic stabilization of the lumbar spine and its effects on adjacent segments: An in vitro experiment
    • Schmoelz W, Huber JF, Nydegger T, et al. Dynamic stabilization of the lumbar spine and its effects on adjacent segments: an in vitro experiment. J Spinal Disord Tech. 2003;16:418-423.
    • (2003) J Spinal Disord Tech , vol.16 , pp. 418-423
    • Schmoelz, W.1    Huber, J.F.2    Nydegger, T.3
  • 12
    • 0342393530 scopus 로고
    • Evaluation of the therapeutic effect of Graf stabilization system
    • Rome
    • Graf H. Evaluation of the therapeutic effect of Graf stabilization system. European Spine Society Meeting. Rome, 1991.
    • (1991) European Spine Society Meeting
    • Graf, H.1
  • 13
    • 0031879695 scopus 로고    scopus 로고
    • Surgical results after soft system stabilization of the lumbar spine in degenerative disc disease-long-term results
    • Brechbuhler D, Markwalder TM, Braun M. Surgical results after soft system stabilization of the lumbar spine in degenerative disc disease-long-term results. Acta Neurochir (Wien). 1998;140:521-525.
    • (1998) Acta Neurochir (Wien) , vol.140 , pp. 521-525
    • Brechbuhler, D.1    Markwalder, T.M.2    Braun, M.3
  • 14
    • 0032523227 scopus 로고    scopus 로고
    • The Graf ligamentoplasty procedure. Comparison with posterolateral fusion in the management of low back pain
    • Hadlow SV, Fagan AB, Hillier TM, et al. The Graf ligamentoplasty procedure. Comparison with posterolateral fusion in the management of low back pain. Spine. 1998;23:1172-1179.
    • (1998) Spine , vol.23 , pp. 1172-1179
    • Hadlow, S.V.1    Fagan, A.B.2    Hillier, T.M.3
  • 15
    • 14344255270 scopus 로고    scopus 로고
    • Non-fusion surgery for degenerative spondylolisthesis using artificial ligament stabilization: Surgical indication and clinical results
    • Kanayama M, Hashimoto T, Shigenobu K, et al. Non-fusion surgery for degenerative spondylolisthesis using artificial ligament stabilization: surgical indication and clinical results. Spine. 2005;30:588-592.
    • (2005) Spine , vol.30 , pp. 588-592
    • Kanayama, M.1    Hashimoto, T.2    Shigenobu, K.3
  • 16
    • 0037239904 scopus 로고    scopus 로고
    • Dynamic stabilization of lumbar motion segments by use of Graf's ligaments: Results with an average follow-up of 7.4 years in 39 highly selected, consecutive patients
    • discussion 14
    • Markwalder TM, Wenger M. Dynamic stabilization of lumbar motion segments by use of Graf's ligaments: results with an average follow-up of 7.4 years in 39 highly selected, consecutive patients. Acta Neurochir (Wien). 2003;145:209-214; discussion 14.
    • (2003) Acta Neurochir (Wien) , vol.145 , pp. 209-214
    • Markwalder, T.M.1    Wenger, M.2
  • 17
    • 0036032274 scopus 로고    scopus 로고
    • Rationale, principles and experimental evaluation of the concept of soft stabilization
    • Mulholland RC, Sengupta DK. Rationale, principles and experimental evaluation of the concept of soft stabilization. Eur Spine J. 2002;11(suppl 2):S198-S205.
    • (2002) Eur Spine J , vol.11 , Issue.SUPPL. 2
    • Mulholland, R.C.1    Sengupta, D.K.2
  • 18
    • 0029037515 scopus 로고
    • The Graf stabilisation system: Early results in 50 patients
    • discussion 35
    • Grevitt MP, Gardner AD, Spilsbury J, et al. The Graf stabilisation system: early results in 50 patients. Eur Spine J. 1995;4:169-175; discussion 35.
    • (1995) Eur Spine J , vol.4 , pp. 169-175
    • Grevitt, M.P.1    Gardner, A.D.2    Spilsbury, J.3
  • 20
    • 77955348863 scopus 로고    scopus 로고
    • Prevention of adjacent level degeneration above a fused vertebral segment: Long-term effect, after a mean follow-up of 8.27 years of the semi-rigid intervertebral fixation as a protective technique for pathological adjacent disc
    • Perrin G, Cristini A. Prevention of adjacent level degeneration above a fused vertebral segment: long-term effect, after a mean follow-up of 8.27 years of the semi-rigid intervertebral fixation as a protective technique for pathological adjacent disc. International Meeting for Advanced Spine Techniques, 2005.
    • (2005) International Meeting for Advanced Spine Techniques
    • Perrin, G.1    Cristini, A.2
  • 23
    • 0036035142 scopus 로고    scopus 로고
    • The dynamic neutralization system for the spine: A multi-center study of a novel non-fusion system
    • Stoll TM, Dubois G, Schwarzenbach O. The dynamic neutralization system for the spine: a multi-center study of a novel non-fusion system. Eur Spine J. 2002;11(suppl 2):S170-S178.
    • (2002) Eur Spine J , vol.11 , Issue.SUPPL. 2
    • Stoll, T.M.1    Dubois, G.2    Schwarzenbach, O.3
  • 24
    • 13444300930 scopus 로고    scopus 로고
    • Clinical experience with the Dynesys semirigid fixation system for the lumbar spine: Surgical and patient-oriented outcome in 50 cases after an average of 2 years
    • Grob D, Benini A, Junge A, et al. Clinical experience with the Dynesys semirigid fixation system for the lumbar spine: surgical and patient-oriented outcome in 50 cases after an average of 2 years. Spine. 2005;30:324-331.
    • (2005) Spine , vol.30 , pp. 324-331
    • Grob, D.1    Benini, A.2    Junge, A.3
  • 25
    • 33645513258 scopus 로고    scopus 로고
    • The surgical treatment of the lumbar disc prolapse: Nucleotomy with additional transpedicular dynamic stabilization versus nucleotomy alone
    • Putzier M, Schneider SV, Funk JF, et al. The surgical treatment of the lumbar disc prolapse: nucleotomy with additional transpedicular dynamic stabilization versus nucleotomy alone. Spine. 2005;30:E109-E114.
    • (2005) Spine , vol.30
    • Putzier, M.1    Schneider, S.V.2    Funk, J.F.3
  • 26
    • 0042831372 scopus 로고    scopus 로고
    • Posterior dynamic stabilization as an alternative for dorso-ventral fusion in spinal stenosis with degenerative instability
    • Cakir B, Ulmar B, Koepp H, et al. Posterior dynamic stabilization as an alternative for dorso-ventral fusion in spinal stenosis with degenerative instability. Z Orthop Ihre Grenzgeb. 2003;141:418-424.
    • (2003) Z Orthop Ihre Grenzgeb , vol.141 , pp. 418-424
    • Cakir, B.1    Ulmar, B.2    Koepp, H.3
  • 27
    • 29944446977 scopus 로고    scopus 로고
    • System of dynamic neutralization in the lumbar spine: Experience on 94 cases
    • Bordes-Monmeneu M, Bordes-Garcia V, Rodrigo-Baeza F, et al. System of dynamic neutralization in the lumbar spine: experience on 94 cases. Neurocirugia (Astur). 2005;16:499-506.
    • (2005) Neurocirugia (Astur) , vol.16 , pp. 499-506
    • Bordes-Monmeneu, M.1    Bordes-Garcia, V.2    Rodrigo-Baeza, F.3
  • 28
    • 68049088137 scopus 로고    scopus 로고
    • Dynesys stabilization system for the treatment of patients with discogenic low back pain
    • Karadimas E, Nicol M, Siddiqui M, et al. Dynesys stabilization system for the treatment of patients with discogenic low back pain. Spine J. 2005;5:112S.
    • (2005) Spine J , vol.5
    • Karadimas, E.1    Nicol, M.2    Siddiqui, M.3
  • 29
    • 40049093550 scopus 로고    scopus 로고
    • Outcome and complications using a dynamic neutralization and stabilization pedicle screw system (Dynesys): Is this a "soft fusion"?
    • Plev D, Sutcliffe J. Outcome and complications using a dynamic neutralization and stabilization pedicle screw system (Dynesys): is this a "soft fusion"? Spine J. 2005;5:141S.
    • (2005) Spine J , vol.5
    • Plev, D.1    Sutcliffe, J.2
  • 30
    • 68049097499 scopus 로고    scopus 로고
    • Nonfusion application of the Dynesys system in the lumbar spine: Early results
    • Delamarter R, Maxwell J, Davis R, et al. Nonfusion application of the Dynesys system in the lumbar spine: early results. Spine J. 2006;6:77S.
    • (2006) Spine J , vol.6
    • Delamarter, R.1    Maxwell, J.2    Davis, R.3
  • 31
    • 68049114987 scopus 로고    scopus 로고
    • Stabilisation of the degenerated lumbar spine in the non-fusion technique with cosmic posterior dynamic system
    • Von Strempel A. Stabilisation of the degenerated lumbar spine in the non-fusion technique with cosmic posterior dynamic system. World Spine J. 2006;1:40-47.
    • (2006) World Spine J , vol.1 , pp. 40-47
    • Von Strempel, A.1
  • 32
    • 34547405903 scopus 로고    scopus 로고
    • Posterior dynamic stabilization of the lumbar spine: Pedicle based stabilization with the AccuFlex rod system
    • Mandigo CE, Sampath P, Kaiser MG. Posterior dynamic stabilization of the lumbar spine: pedicle based stabilization with the AccuFlex rod system. Neurosurg Focus. 2007;22:E9.
    • (2007) Neurosurg Focus , vol.22
    • Mandigo, C.E.1    Sampath, P.2    Kaiser, M.G.3
  • 34
    • 34547424478 scopus 로고    scopus 로고
    • Treatment of lumbar spinal stenosis with a total posterior arthroplasty prosthesis: Implant description, surgical technique, and a prospective report on 29 patients
    • McAfee P, Khoo LT, Pimenta L, et al. Treatment of lumbar spinal stenosis with a total posterior arthroplasty prosthesis: implant description, surgical technique, and a prospective report on 29 patients. Neurosurg Focus. 2007;22:E13.
    • (2007) Neurosurg Focus , vol.22
    • McAfee, P.1    Khoo, L.T.2    Pimenta, L.3
  • 35
    • 0026620583 scopus 로고
    • The stabilizing system of the spine. Part II. Neutral zone and instability hypothesis
    • discussion 397
    • Panjabi MM. The stabilizing system of the spine. Part II. Neutral zone and instability hypothesis. J Spinal Disord. 1992;5:390-396; discussion 397.
    • (1992) J Spinal Disord , vol.5 , pp. 390-396
    • Panjabi, M.M.1
  • 36
    • 0026735468 scopus 로고    scopus 로고
    • Panjabi MM. The stabilizing system of the spine. Part I. Function, dysfunction, adaptation, and enhancement. J Spinal Disord. 1992;5:383-389; discussion 397.
    • Panjabi MM. The stabilizing system of the spine. Part I. Function, dysfunction, adaptation, and enhancement. J Spinal Disord. 1992;5:383-389; discussion 397.
  • 37
    • 34547463730 scopus 로고    scopus 로고
    • Biomechanics of the posterior lumbar articulating elements
    • Serhan HA, Varnavas G, Dooris AP, et al. Biomechanics of the posterior lumbar articulating elements. Neurosurg Focus. 2007;22:E1.
    • (2007) Neurosurg Focus , vol.22
    • Serhan, H.A.1    Varnavas, G.2    Dooris, A.P.3
  • 38
    • 0042069643 scopus 로고    scopus 로고
    • The fate of the adjacent motion segments after lumbar fusion
    • Gillet P. The fate of the adjacent motion segments after lumbar fusion. J Spinal Disord Tech. 2003;16:338-345.
    • (2003) J Spinal Disord Tech , vol.16 , pp. 338-345
    • Gillet, P.1
  • 39
    • 0023273877 scopus 로고
    • Long-term follow-up of lower lumbar fusion patients
    • Lehmann TR, Spratt KF, Tozzi JE, et al. Long-term follow-up of lower lumbar fusion patients. Spine. 1987;12:97-104.
    • (1987) Spine , vol.12 , pp. 97-104
    • Lehmann, T.R.1    Spratt, K.F.2    Tozzi, J.E.3
  • 40
    • 0030473152 scopus 로고    scopus 로고
    • Adjacent-segment degeneration after lumbar fusion with instrumentation: A retrospective study
    • Rahm MD, Hall BB. Adjacent-segment degeneration after lumbar fusion with instrumentation: a retrospective study. J Spinal Disord. 1996;9:392-400.
    • (1996) J Spinal Disord , vol.9 , pp. 392-400
    • Rahm, M.D.1    Hall, B.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.