-
1
-
-
0027357451
-
The use of resonant frequency measurements for the noninvasive assessment of mechanical stiffness of the healing tibia
-
8433203 1:STN:280:DyaK3s7mtl2mtQ%3D%3D
-
SK Benirschke H Mirels D Jones AF Tencer 1993 The use of resonant frequency measurements for the noninvasive assessment of mechanical stiffness of the healing tibia J Orthop Trauma. 7 64 71 8433203 1:STN:280: DyaK3s7mtl2mtQ%3D%3D
-
(1993)
J Orthop Trauma.
, vol.7
, pp. 64-71
-
-
Benirschke, S.K.1
Mirels, H.2
Jones, D.3
Tencer, A.F.4
-
2
-
-
0035067047
-
The reliability of plain radiography in experimental fracture healing
-
DOI 10.1007/s002560000317
-
TJ Blokhuis JH de Bruine JA Bramer FC den Boer FC Bakker P Patka HJ Haarman RA Manoliu 2001 The reliability of plain radiography in experimental fracture healing Skeletal Radiol. 30 151 156 11357453 10.1007/s002560000317 1:STN:280:DC%2BD3M3ms1Ojuw%3D%3D (Pubitemid 32288159)
-
(2001)
Skeletal Radiology
, vol.30
, Issue.3
, pp. 151-156
-
-
Blokhuis, T.J.1
De Bruine, J.H.D.2
Bramer, J.A.M.3
Den Boer, F.C.4
Bakker, F.C.5
Patka, P.6
Haarman, H.J.Th.M.7
Manoliu, R.A.8
-
3
-
-
0032893677
-
Digital image analysis: Improving accuracy and reproducibility of radiographic measurement
-
DOI 10.1016/S0268-0033(98)00113-2, PII S0268003398001132
-
M Bould S Barnard ID Learmonth JL Cunningham JRW Hardy 1999 Digital image analysis: Improving accuracy and reproducibility of radiographic measurement Clin Biomech. 14 434 437 10.1016/S0268-0033(98)00113-2 1:STN:280: DyaK1Mvlslersw%3D%3D (Pubitemid 29229656)
-
(1999)
Clinical Biomechanics
, vol.14
, Issue.6
, pp. 434-437
-
-
Bould, M.1
Barnard, S.2
Learmonth, I.D.3
Cunningham, J.L.4
Hardy, J.R.W.5
-
4
-
-
0018255372
-
Utilisation clinique de jauges de contrainte-situation actuelle et perspectives d'avenir
-
756663 1:STN:280:DyaL3c%2FmtFyjsg%3D%3D
-
F Burny R Bourgois M Donkerwolcke F Moulart 1978 Utilisation clinique de jauges de contrainte-situation actuelle et perspectives d'avenir Acta Orthop Belg. 44 895 920 756663 1:STN:280:DyaL3c%2FmtFyjsg%3D%3D
-
(1978)
Acta Orthop Belg.
, vol.44
, pp. 895-920
-
-
Burny, F.1
Bourgois, R.2
Donkerwolcke, M.3
Moulart, F.4
-
5
-
-
0036934223
-
Monitoring and healing analysis of 100 tibial shaft fractures
-
DOI 10.1007/s00423-002-0306-x
-
L Claes R Grass T Schmickal B Kisse C Eggers H Gerngross W Mutschler M Arand T Wintermeyer A Wentzensen 2002 Monitoring and healing analysis of 100 tibial shaft fractures Langenbecks Arch Surg. 387 146 152 12172859 10.1007/s00423-002-0306-x 1:STN:280:DC%2BD38vhvVeisg%3D%3D (Pubitemid 36061876)
-
(2002)
Langenbeck's Archives of Surgery
, vol.387
, Issue.3-4
, pp. 146-152
-
-
Claes, L.1
Grass, R.2
Schmickal, T.3
Kisse, B.4
Eggers, C.5
Gerngross, H.6
Mutschler, W.7
Arand, M.8
Wintermeyer, T.9
Wentzensen, A.10
-
6
-
-
51349111786
-
Variability in the assessment of fracture-healing in orthopaedic trauma studies
-
18762645 10.2106/JBJS.G.01580
-
LA Corrales S Morshed M Bhandari T Miclau III 2008 Variability in the assessment of fracture-healing in orthopaedic trauma studies J Bone Joint Surg Am. 90 1862 1868 18762645 10.2106/JBJS.G.01580
-
(2008)
J Bone Joint Surg Am.
, vol.90
, pp. 1862-1868
-
-
Corrales, L.A.1
Morshed, S.2
Bhandari, M.3
Miclau Iii, T.4
-
7
-
-
0025435226
-
Biomechanical measurements of fracture repair
-
2201773 10.3109/03091909009015420 1:STN:280:DyaK3czlsFWltw%3D%3D
-
JL Cunningham J Kenwright CJ Kershaw 1990 Biomechanical measurements of fracture repair J Med Eng Technol. 14 92 101 2201773 10.3109/03091909009015420 1:STN:280:DyaK3czlsFWltw%3D%3D
-
(1990)
J Med Eng Technol.
, vol.14
, pp. 92-101
-
-
Cunningham, J.L.1
Kenwright, J.2
Kershaw, C.J.3
-
8
-
-
0031928536
-
Quantification of fracture healing with three-dimensional computed tomography
-
DOI 10.1007/s004020050263
-
FC Den Boer JAM Bramer P Patka FC Bakker RH Barentsen AJ Feilzer ESM de Lange HJTM Haarman 1998 Quantification of fracture healing with three-dimensional computed tomography Arch Orthop and Trauma Surg. 117 345 350 10.1007/s004020050263 (Pubitemid 28365061)
-
(1998)
Archives of Orthopaedic and Trauma Surgery
, vol.117
, Issue.6-7
, pp. 345-350
-
-
Den Boer, F.C.1
Bramer, J.A.M.2
Patka, P.3
Bakker, F.C.4
Barentsen, R.H.5
Feilzer, A.J.6
De Lange, E.S.M.7
Haarman, H.J.T.M.8
-
9
-
-
0033962307
-
Fracture stiffness measurement using the orthometer: Reproducibility and sources of error
-
DOI 10.1016/S0268-0033(99)00029-7, PII S0268003399000297
-
SJ Eastaugh-Waring JR Hardy JL Cunningham 2000 Fracture stiffness measurement using the Orthometer: reproducibility and sources of error Clin Biomech. 15 140 142 10.1016/S0268-0033(99)00029-7 1:STN:280: DC%2BD3c%2FptlSqsQ%3D%3D (Pubitemid 30016072)
-
(2000)
Clinical Biomechanics
, vol.15
, Issue.2
, pp. 140-142
-
-
Eastaugh-Waring, S.J.1
Hardy, J.R.W.2
Cunningham, J.L.3
-
10
-
-
0031127025
-
Temporal changes in dynamic inter-fragmentary motion and callus formation in fractures
-
10.1016/S0021-9290(96)00156-X
-
TN Gardner JRW Hardy M Evans J Kenwright 1996 Temporal changes in dynamic inter-fragmentary motion and callus formation in fractures J Biomech. 30 315 321 10.1016/S0021-9290(96)00156-X
-
(1996)
J Biomech.
, vol.30
, pp. 315-321
-
-
Gardner, T.N.1
Hardy, J.R.W.2
Evans, M.3
Kenwright, J.4
-
12
-
-
0036711745
-
Biomechanical monitoring of healing bone based on acoustic emission technology
-
12218489 10.1097/00003086-200209000-00023
-
Y Hirasawa S Takai WC Kim N Takenaka N Yoshino Y Watanabe 2002 Biomechanical monitoring of healing bone based on acoustic emission technology Clin Orthop Relat Res 402 236 244 12218489 10.1097/00003086-200209000-00023
-
(2002)
Clin Orthop Relat Res
, vol.402
, pp. 236-244
-
-
Hirasawa, Y.1
Takai, S.2
Kim, W.C.3
Takenaka, N.4
Yoshino, N.5
Watanabe, Y.6
-
13
-
-
39149137856
-
Weight bearing after tibial fracture as a guide to healing
-
DOI 10.1016/j.clinbiomech.2007.09.013, PII S0268003307002185
-
CC Joslin SJ Eastaugh-Waring JRW Hardy JL Cunningham 2008 Weight bearing after tibial fracture as a guide to healing Clin Biomech. 23 329 333 10.1016/j.clinbiomech.2007.09.013 1:STN:280:DC%2BD1c7jsVSgtQ%3D%3D (Pubitemid 351253712)
-
(2008)
Clinical Biomechanics
, vol.23
, Issue.3
, pp. 329-333
-
-
Joslin, C.C.1
Eastaugh-Waring, S.J.2
Hardy, J.R.W.3
Cunningham, J.L.4
-
14
-
-
0016164608
-
The three dimensional measurement of tibia fracture motion by photogrammetry
-
4430161 10.1097/00003086-197411000-00008
-
FG Lippert C Hirsch 1974 The three dimensional measurement of tibia fracture motion by photogrammetry Clin Orthop Relat Res. 105 130 143 4430161 10.1097/00003086-197411000-00008
-
(1974)
Clin Orthop Relat Res.
, vol.105
, pp. 130-143
-
-
Lippert, F.G.1
Hirsch, C.2
-
15
-
-
33644976374
-
Transosseous application of low-intensity ultrasound for the enhancement and monitoring of fracture healing process in a sheep osteotomy model
-
16361120 10.1016/j.bone.2005.10.012
-
KN Malizos AA Papachristos VC Protopappas DI Fotiadis 2006 Transosseous application of low-intensity ultrasound for the enhancement and monitoring of fracture healing process in a sheep osteotomy model Bone. 38 530 539 16361120 10.1016/j.bone.2005.10.012
-
(2006)
Bone.
, vol.38
, pp. 530-539
-
-
Malizos, K.N.1
Papachristos, A.A.2
Protopappas, V.C.3
Fotiadis, D.I.4
-
16
-
-
0031734172
-
Concepts of fracture union, delayed union and non-union
-
10.1097/00003086-199810001-00004
-
D Marsh 1998 Concepts of fracture union, delayed union and non-union Clin Orthop Relat Res. 355S S22 S30 10.1097/00003086-199810001-00004
-
(1998)
Clin Orthop Relat Res.
, vol.355
-
-
Marsh, D.1
-
17
-
-
34147141877
-
Fracture healing assessment comparing stiffness measurements using radiographs
-
17159575 1:STN:280:DC%2BD2s3nvFeltw%3D%3D
-
D McClelland PBM Thomas G Bancroft CI Moorcroft 2007 Fracture healing assessment comparing stiffness measurements using radiographs Clin Orthop Relat Res. 457 214 219 17159575 1:STN:280:DC%2BD2s3nvFeltw%3D%3D
-
(2007)
Clin Orthop Relat Res.
, vol.457
, pp. 214-219
-
-
McClelland, D.1
Thomas, P.B.M.2
Bancroft, G.3
Moorcroft, C.I.4
-
18
-
-
0029681729
-
Assessment of fracture healing in the tibia using the impulse response method
-
8926555 10.1097/00005131-199601000-00008 1:STN:280:DyaK28vgtlWjtA%3D%3D
-
Y Nakatsuchi A Tsuchikane A Nomura 1996 Assessment of fracture healing in the tibia using the impulse response method J Orthop Trauma. 10 50 62 8926555 10.1097/00005131-199601000-00008 1:STN:280:DyaK28vgtlWjtA%3D%3D
-
(1996)
J Orthop Trauma.
, vol.10
, pp. 50-62
-
-
Nakatsuchi, Y.1
Tsuchikane, A.2
Nomura, A.3
-
19
-
-
0026350109
-
Clinical factors and the size of the external callus in tibial shaft fractures
-
1959282
-
OOA Oni J Dunning RJ Mobbs PJ Gregg 1991 Clinical factors and the size of the external callus in tibial shaft fractures Clin Orthop Relat Res. 273 278 283 1959282
-
(1991)
Clin Orthop Relat Res.
, vol.273
, pp. 278-283
-
-
Oni, O.O.A.1
Dunning, J.2
Mobbs, R.J.3
Gregg, P.J.4
-
21
-
-
0032716271
-
Correlation of radiographic measurements with biomechanical test results
-
10613178 10.1097/00003086-199911000-00033
-
H Sano HK Uhthoff DS Backman A Yeadon 1999 Correlation of radiographic measurements with biomechanical test results Clin Orthop Relat Res. 368 271 278 10613178 10.1097/00003086-199911000-00033
-
(1999)
Clin Orthop Relat Res.
, vol.368
, pp. 271-278
-
-
Sano, H.1
Uhthoff, H.K.2
Backman, D.S.3
Yeadon, A.4
-
22
-
-
0029964331
-
Effect of loading and fracture motions on diaphyseal tibial fractures
-
DOI 10.1002/jor.1100140114
-
A Sarmiento HA McKellop A Llinas SH Park B Lu W Stetson R Rao 1996 Effect of loading and fracture motions on diaphyseal tibial fractures J Orthop Res. 14 80 84 8618171 10.1002/jor.1100140114 1:STN:280:DyaK287otFKntg%3D%3D (Pubitemid 26091606)
-
(1996)
Journal of Orthopaedic Research
, vol.14
, Issue.1
, pp. 80-84
-
-
Sarmiento, A.1
McKellop, H.A.2
Llinas, A.3
Park, S.-H.4
Lu, B.5
Stetson, W.6
Rao, R.7
-
23
-
-
0029787036
-
The effect of fracture and fracture fixation on ultrasonic velocity and attenuation
-
DOI 10.1088/0967-3334/17/3/006
-
J Saulgozis I Pontaga G Lowet G Van der Perre 1996 The effect of fracture and fracture fixation on ultrasonic velocity and attenuation Physiol Meas. 17 201 211 8870060 10.1088/0967-3334/17/3/006 1:STN:280:DyaK2s%2FitlOjsw%3D%3D (Pubitemid 26273902)
-
(1996)
Physiological Measurement
, vol.17
, Issue.3
, pp. 201-211
-
-
Saulgozis, J.1
Pontaga, I.2
Lowet, G.3
Van Der Perre, G.4
-
24
-
-
0023192302
-
The effect of head injury on fracture healing
-
3611151 1:STN:280:DyaL2s3otVaqsw%3D%3D
-
RF Spencer 1987 The effect of head injury on fracture healing J Bone Joint Surg Br. 69 525 528 3611151 1:STN:280:DyaL2s3otVaqsw%3D%3D
-
(1987)
J Bone Joint Surg Br.
, vol.69
, pp. 525-528
-
-
Spencer, R.F.1
-
25
-
-
0035133885
-
Outcome in fracture healing: A review
-
DOI 10.1016/S0020-1383(00)00126-1, PII S0020138300001261
-
R Wade J Richardson 2001 Outcome in fracture healing: a review Injury. 32 109 114 11223041 10.1016/S0020-1383(00)00126-1 1:STN:280:DC%2BD3M3hsFCntA%3D%3D (Pubitemid 32153697)
-
(2001)
Injury
, vol.32
, Issue.2
, pp. 109-114
-
-
Wade, R.1
Richardson, J.2
-
26
-
-
0034991372
-
Fracture stiffness as a guide to the management of tibial fractures
-
11380125 10.1302/0301-620X.83B4.11081 1:STN:280:DC%2BD3M3psFKktw%3D%3D
-
RH Wade CI Moorcroft PB Thomas 2001 Fracture stiffness as a guide to the management of tibial fractures J Bone Joint Surg Br. 83 533 535 11380125 10.1302/0301-620X.83B4.11081 1:STN:280:DC%2BD3M3psFKktw%3D%3D
-
(2001)
J Bone Joint Surg Br.
, vol.83
, pp. 533-535
-
-
Wade, R.H.1
Moorcroft, C.I.2
Thomas, P.B.3
|