Digital image analysis: Improving accuracy and reproducibility of radiographic measurement

Author keywords

Accuracy; Digital image analysis; Radiographic measurement; Reproducibility; Total hip arthroplasty

Indexed keywords

IMAGE ANALYSIS; MEDICAL IMAGING; RADIOGRAPHY;

EID: 0032893677     PISSN: 02680033     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0268-0033(98)00113-2     Document Type: Article
Times cited : (14)

References (10)
  • 1
    • 0030668935 scopus 로고    scopus 로고
    • Factors affecting aseptic failure of fixation after primary Charnley total hip arthroplasty
    • Kobayashi S, Takaoka K, Saito N, Hisa K. Factors affecting aseptic failure of fixation after primary Charnley total hip arthroplasty. JBJS 1997; 79-A:1618-27.
    • (1997) JBJS , vol.79 , Issue.A , pp. 1618-1627
    • Kobayashi, S.1    Takaoka, K.2    Saito, N.3    Hisa, K.4
  • 2
    • 0015692118 scopus 로고
    • The nine and ten year results of the low friction arthroplasty of the hip
    • Charnley J, Cupic Z. The nine and ten year results of the low friction arthroplasty of the hip. Clin Orthop 1973;95:9-25.
    • (1973) Clin Orthop , vol.95 , pp. 9-25
    • Charnley, J.1    Cupic, Z.2
  • 3
    • 0016823891 scopus 로고
    • Rate of wear in total hip replacement
    • Charnley J,Halley DK. Rate of wear in total hip replacement. Clin Orthop 1973;112:170-9.
    • (1973) Clin Orthop , vol.112 , pp. 170-179
    • Charnley, J.1    Halley, D.K.2
  • 4
    • 0345447297 scopus 로고
    • Can wear in total hip arthroplasties be assessed from radiographs?
    • Clarke IC, Black K, Rennie C, Amstutz HC. Can wear in total hip arthroplasties be assessed from radiographs? Clin Orthop 1973;112:170-9.
    • (1973) Clin Orthop , vol.112 , pp. 170-179
    • Clarke, I.C.1    Black, K.2    Rennie, C.3    Amstutz, H.C.4
  • 5
    • 0022219799 scopus 로고
    • Direction and rate of socket wear in Charnley low-friction arthroplasty
    • Wroblewski, BM. Direction and rate of socket wear in Charnley low-friction arthroplasty. JBJS 1985 67-B :757-61.
    • (1985) JBJS , vol.67 , Issue.B , pp. 757-761
    • Wroblewski, B.M.1
  • 6
    • 0025343488 scopus 로고
    • Effect of femoral head size on wear of the polyethylene acetabular component
    • Livermore J, Ilstrup D,Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. JBJS 1990;72-A:518-28.
    • (1990) JBJS , vol.72 , Issue.A , pp. 518-528
    • Livermore, J.1    Ilstrup, D.2    Morrey, B.3
  • 7
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;8:307-10.
    • (1986) Lancet , vol.8 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.