메뉴 건너뛰기




Volumn 34, Issue 13, 2009, Pages 1376-1384

Nucleus replacement with the DASCOR disc arthroplasty device: Interim two-year efficacy and safety results from two prospective, non-randomized multicenter european studies

Author keywords

Arthroplasty; Clinical study; Degenerative disc disease; Intervertebral disc; Lumbar spine; Nucleus prosthesis; Prospective studies

Indexed keywords

COCODAMOL; DEXTROPROPOXYPHENE; IBUPROFEN; NAPROXEN; PENTAZOCINE; PIROXICAM;

EID: 67749113555     PISSN: 03622436     EISSN: 15281159     Source Type: Journal    
DOI: 10.1097/BRS.0b013e3181a3967f     Document Type: Article
Times cited : (45)

References (20)
  • 1
    • 0036142746 scopus 로고    scopus 로고
    • Prosthetic disc replacement: The future?
    • Bao QB, Yuan HA. Prosthetic disc replacement: the future? Clin Orthop 2002:139-145
    • (2002) Clin Orthop , pp. 139-145
    • Bao, Q.B.1    Yuan, H.A.2
  • 2
    • 0036605819 scopus 로고    scopus 로고
    • New technologies in spine: Nucleus replacement
    • Bao QB, Yuan HA. New technologies in spine: nucleus replacement. Spine 2002;27:1245-1247
    • (2002) Spine , vol.27 , pp. 1245-1247
    • Bao, Q.B.1    Yuan, H.A.2
  • 3
    • 0013984953 scopus 로고
    • Arthroplasty with intercorporeal endoprosthesis in herniated disc and in painful disc
    • Fernstrom U. Arthroplasty with intercorporeal endoprosthesis in herniated disc and in painful disc. Acta Chir Scand Suppl 1966;357:154-159
    • (1966) Acta Chir Scand Suppl , vol.357 , pp. 154-159
    • Fernstrom, U.1
  • 4
    • 0036035626 scopus 로고    scopus 로고
    • Spine arthroplasty: A historical review
    • Szpalski M, Gunzburg R, Mayer M. Spine arthroplasty: a historical review. Eur Spine J 2002;11(suppl 2):S65- 84.
    • (2002) Eur Spine J , vol.11 , Issue.SUPPL. 2
    • Szpalski, M.1    Gunzburg, R.2    Mayer, M.3
  • 9
    • 67749121800 scopus 로고    scopus 로고
    • Mechanical and biomechanical characterization of a polyurethane nucleus replacement device injected and in situ cured within a balloon
    • Tsantrizos A, Ordway N, Martz E, et al. Mechanical and biomechanical characterization of a polyurethane nucleus replacement device injected and in situ cured within a balloon. SAS J 2008;2:28-39.
    • (2008) SAS J , vol.2 , pp. 28-39
    • Tsantrizos, A.1    Ordway, N.2    Martz, E.3
  • 13
    • 67749130438 scopus 로고    scopus 로고
    • Summary of safety and effectiveness, Prodisc-L total disc replacement
    • Administration FDA, ed
    • Melkerson MN. Summary of safety and effectiveness, Prodisc-L total disc replacement. In: Administration FDA, ed. PMA Approval Document P050010; 2006.
    • (2006) PMA Approval Document P050010
    • Melkerson, M.N.1
  • 14
    • 84869563989 scopus 로고    scopus 로고
    • Summary of safety and effectiveness, CHARITÉ artificial disc
    • Administration FDA, ed
    • Tillman DT. Summary of safety and effectiveness, CHARITÉ artificial disc. In: Administration FDA, ed. PMA Approval Document P040006; 2004.
    • (2004) PMA Approval Document P040006
    • Tillman, D.T.1
  • 16
    • 22644436393 scopus 로고    scopus 로고
    • A prospective, randomized, multicenter Food and Drug Administration Investigational Device Exemptions study of lumbar total disc replacement with the CHARITÉ artificial disc versus lumbar fusion - Part I: Evaluation of clinical outcomes
    • DOI 10.1097/01.brs.0000170587.32676.0e
    • Blumenthal S, McAfee PC, Guyer RD, et al. A prospective, randomized, multi-centermulti-center Food and Drug Administration investigational device exemptions study of lumbar total disc replacement with the CHARITÉ artificial disc versus lumbar fusion, part I: evaluation of clinical outcomes. Spine 2005;30:1565-75; discussion E387-91. (Pubitemid 41024950)
    • (2005) Spine , vol.30 , Issue.14 , pp. 1565-1575
    • Blumenthal, S.1    McAfee, P.C.2    Guyer, R.D.3    Hochschuler, S.H.4    Geisler, F.H.5    Holt, R.T.6    Garcia Jr., R.7    Regan, J.J.8    Ohnmeiss, D.D.9
  • 17
    • 0037096715 scopus 로고    scopus 로고
    • Artificial nucleus replacement: Clinical experience
    • Klara PM, Ray CD. Artificial nucleus replacement: clinical experience. Spine 2002;27:1374-1377
    • (2002) Spine , vol.27 , pp. 1374-1377
    • Klara, P.M.1    Ray, C.D.2
  • 18
    • 67749094540 scopus 로고    scopus 로고
    • Internal strains in the healthy lumbar intervertebral disc (also sumb. for basic award)
    • Tsantrizos AST, Aebi M, Steffen T. Internal strains in the healthy lumbar intervertebral disc (also sumb. for basic award). Eur Spine J 2003;12:S35.
    • (2003) Eur Spine J , vol.12
    • Tsantrizos, A.S.T.1    Aebi, M.2    Steffen, T.3
  • 19
    • 0030454241 scopus 로고    scopus 로고
    • Migration of the nucleus pulposus within the intervertebral disc during flexion and extension of the spine
    • Fennell AJ, Jones AP, Hukins DW. Migration of the nucleus pulposus within the intervertebral disc during flexion and extension of the spine. Spine 1996; 21:2753-2757
    • (1996) Spine , vol.21 , pp. 2753-2757
    • Fennell, A.J.1    Jones, A.P.2    Hukins, D.W.3
  • 20
    • 0031429135 scopus 로고    scopus 로고
    • Quantification of lumbar intradiscal deformation during flexion and extension, by mathematical analysis of magnetic resonance imaging pixel intensity profiles
    • Brault JS, Driscoll DM, Laakso LL, et al. Quantification of lumbar intradiscal deformation during flexion and extension, by mathematical analysis of magnetic resonance imaging pixel intensity profiles. Spine 1997; 22:2066-2072
    • (1997) Spine , vol.22 , pp. 2066-2072
    • Brault, J.S.1    Driscoll, D.M.2    Laakso, L.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.