-
1
-
-
0342514575
-
Low back pain in relation to lumbar disc degeneration
-
Luoma K., Riihimaki H., Luukkonen R., Raininko R., Viikari-Juntura E., and Lamminen A. Low back pain in relation to lumbar disc degeneration. Spine 25 4 (2000) 487-492
-
(2000)
Spine
, vol.25
, Issue.4
, pp. 487-492
-
-
Luoma, K.1
Riihimaki, H.2
Luukkonen, R.3
Raininko, R.4
Viikari-Juntura, E.5
Lamminen, A.6
-
2
-
-
0019961658
-
Medical applications of polymeric materials
-
Bruck S.D. Medical applications of polymeric materials. Med Prog Technol 9 1 (1982) 1-16
-
(1982)
Med Prog Technol
, vol.9
, Issue.1
, pp. 1-16
-
-
Bruck, S.D.1
-
3
-
-
3342924114
-
Polyurethane polymer (ostamer): its use in fractured and diseased bones; experimental results
-
Mandarino M.P., and Salvatore J.E. Polyurethane polymer (ostamer): its use in fractured and diseased bones; experimental results. Surg Forum 9 (1958) 762-765
-
(1958)
Surg Forum
, vol.9
, pp. 762-765
-
-
Mandarino, M.P.1
Salvatore, J.E.2
-
4
-
-
0036035142
-
The dynamic neutralization system for the spine: a multi-center study of a novel non-fusion system
-
Stoll T.M., Dubois G., and Schwarzenbach O. The dynamic neutralization system for the spine: a multi-center study of a novel non-fusion system. Eur Spine J 11 (2002) S170-S178
-
(2002)
Eur Spine J
, vol.11
-
-
Stoll, T.M.1
Dubois, G.2
Schwarzenbach, O.3
-
5
-
-
33751116552
-
Biomechanical evaluation of a new total posterior-element replacement system
-
Wilke H.J., Schmidt H., Werner K., Schmolz W., and Drumm J. Biomechanical evaluation of a new total posterior-element replacement system. Spine 31 24 (2006) 2790-2796
-
(2006)
Spine
, vol.31
, Issue.24
, pp. 2790-2796
-
-
Wilke, H.J.1
Schmidt, H.2
Werner, K.3
Schmolz, W.4
Drumm, J.5
-
7
-
-
0036034166
-
A spiral implant as nucleus prosthesis in the lumbar spine
-
Korge A., Nydegger T., Polard J.L., Mayer H.M., and Husson J.L. A spiral implant as nucleus prosthesis in the lumbar spine. Eur Spine J 11 (2002) S149-S153
-
(2002)
Eur Spine J
, vol.11
-
-
Korge, A.1
Nydegger, T.2
Polard, J.L.3
Mayer, H.M.4
Husson, J.L.5
-
8
-
-
77949840149
-
Nucleus replacement with the DASCORTM Disc Arthroplasty System: Two year follow up results obtained from two prospective European multi-center clinical studies
-
Paper presented at:, May 1-4, Berlin, Germany
-
Ahrens M, Donkersloot P, Martens F, et al. Nucleus replacement with the DASCORTM Disc Arthroplasty System: Two year follow up results obtained from two prospective European multi-center clinical studies. Paper presented at: Spine Arthroplasty Society; May 1-4, 2007; Berlin, Germany.
-
(2007)
Spine Arthroplasty Society
-
-
Ahrens, M.1
Donkersloot, P.2
Martens, F.3
-
10
-
-
0033104976
-
Low back three-dimensional joint forces, kinematics, and kinetics during walking
-
Callaghan J.P., Patla A.E., and McGill S.M. Low back three-dimensional joint forces, kinematics, and kinetics during walking. Clin Biomech 14 3 (1999) 203-216
-
(1999)
Clin Biomech
, vol.14
, Issue.3
, pp. 203-216
-
-
Callaghan, J.P.1
Patla, A.E.2
McGill, S.M.3
-
11
-
-
0014895535
-
Intravital dynamic pressure measurements in lumbar discs. A study of common movements, maneuvers and exercises
-
Nachemson A., and Elfstrom G. Intravital dynamic pressure measurements in lumbar discs. A study of common movements, maneuvers and exercises. Scand J Rehabil Med 1S (1970) 1-40
-
(1970)
Scand J Rehabil Med
, vol.1 S
, pp. 1-40
-
-
Nachemson, A.1
Elfstrom, G.2
-
12
-
-
0032893675
-
Segmental movements of the spine during treadmill walking with normal speed
-
Syczewska M., Oberg T., and Karlsson D. Segmental movements of the spine during treadmill walking with normal speed. Clin Biomech 14 6 (1999) 384-388
-
(1999)
Clin Biomech
, vol.14
, Issue.6
, pp. 384-388
-
-
Syczewska, M.1
Oberg, T.2
Karlsson, D.3
-
13
-
-
0026620583
-
The stabilizing system of the spine. Part II. Neutral zone and instability hypothesis
-
Panjabi M.M. The stabilizing system of the spine. Part II. Neutral zone and instability hypothesis. J Spinal Disord 5 4 (1992) 390-396
-
(1992)
J Spinal Disord
, vol.5
, Issue.4
, pp. 390-396
-
-
Panjabi, M.M.1
-
14
-
-
0035097582
-
Replacing the nucleus pulposus of the intervertebral disk: prediction of suitable properties of a replacement material using finite element analysis
-
Meakin J.R., and Hukins D.W. Replacing the nucleus pulposus of the intervertebral disk: prediction of suitable properties of a replacement material using finite element analysis. J Mater Sci 12 (2001) 207-213
-
(2001)
J Mater Sci
, vol.12
, pp. 207-213
-
-
Meakin, J.R.1
Hukins, D.W.2
-
15
-
-
0034894353
-
Replacing the nucleus pulposus of the intervertebral disc
-
Meakin J.R., Reid J.E., and Hukins D.W. Replacing the nucleus pulposus of the intervertebral disc. Clin Biomech 16 7 (2001) 560-565
-
(2001)
Clin Biomech
, vol.16
, Issue.7
, pp. 560-565
-
-
Meakin, J.R.1
Reid, J.E.2
Hukins, D.W.3
-
16
-
-
0024471422
-
Internal deformations of intact and denucleated human lumbar discs subjected to compression, flexion, and extension loads
-
Seroussi R.E., Krag M.H., Muller D.L., and Pope M.H. Internal deformations of intact and denucleated human lumbar discs subjected to compression, flexion, and extension loads. J Orthop Res 7 1 (1989) 122-131
-
(1989)
J Orthop Res
, vol.7
, Issue.1
, pp. 122-131
-
-
Seroussi, R.E.1
Krag, M.H.2
Muller, D.L.3
Pope, M.H.4
-
17
-
-
26444544460
-
Internal strains in healthy and degenerated lumbar intervertebral discs
-
Tsantrizos A., Ito K., Aebi M., and Steffen T. Internal strains in healthy and degenerated lumbar intervertebral discs. Spine 30 19 (2005) 2129-2137
-
(2005)
Spine
, vol.30
, Issue.19
, pp. 2129-2137
-
-
Tsantrizos, A.1
Ito, K.2
Aebi, M.3
Steffen, T.4
-
18
-
-
0015325901
-
Lumbar intervertebral disc degeneration: the influence of geometrical features on the pattern of disc degeneration--a post mortem study
-
Farfan H.F., Huberdeau R.M., and Dubow H.I. Lumbar intervertebral disc degeneration: the influence of geometrical features on the pattern of disc degeneration--a post mortem study. J Bone Joint Surg 54A 3 (1972) 492-510
-
(1972)
J Bone Joint Surg
, vol.54 A
, Issue.3
, pp. 492-510
-
-
Farfan, H.F.1
Huberdeau, R.M.2
Dubow, H.I.3
-
19
-
-
0029850589
-
'Stress' distributions inside intervertebral discs. The effects of age and degeneration
-
Adams M.A., McNally D.S., and Dolan P. 'Stress' distributions inside intervertebral discs. The effects of age and degeneration. J Bone Joint Surg 78B 6 (1996) 965-972
-
(1996)
J Bone Joint Surg
, vol.78 B
, Issue.6
, pp. 965-972
-
-
Adams, M.A.1
McNally, D.S.2
Dolan, P.3
-
20
-
-
77949863436
-
Partial disc replacement in the baboon lumbar spine
-
Paper presented at:, May 9-13, Montreal, Quebec, Canada
-
Cook S, Salkeld S, Rogozinski A, Rogozinski C, Bailey K. Partial disc replacement in the baboon lumbar spine. Paper presented at: Spine Arthroplasty Society; May 9-13, 2006; Montreal, Quebec, Canada.
-
(2006)
Spine Arthroplasty Society
-
-
Cook, S.1
Salkeld, S.2
Rogozinski, A.3
Rogozinski, C.4
Bailey, K.5
-
21
-
-
0013984953
-
Arthroplasty with intercorporal endoprothesis in herniated disc and in painful disc
-
Fernstrom U. Arthroplasty with intercorporal endoprothesis in herniated disc and in painful disc. Acta Chir Scand Suppl 357 (1966) S154-S159
-
(1966)
Acta Chir Scand Suppl
, vol.357
-
-
Fernstrom, U.1
-
22
-
-
34548024204
-
NUBACTM Intradiscal Arthroplasty: Preclinical studies, and preliminary safety and efficacy evaluations
-
Bao Q.B., Songer M., Pimenta L., et al. NUBACTM Intradiscal Arthroplasty: Preclinical studies, and preliminary safety and efficacy evaluations. SAS J 1 1 (2007) 36-46
-
(2007)
SAS J
, vol.1
, Issue.1
, pp. 36-46
-
-
Bao, Q.B.1
Songer, M.2
Pimenta, L.3
-
23
-
-
0031468627
-
Does the thickness of the vertebral subchondral bone reflect the composition of the intervertebral disc?
-
Roberts S., McCall I.W., Menage J., Haddaway M.J., and Eisenstein S.M. Does the thickness of the vertebral subchondral bone reflect the composition of the intervertebral disc?. Eur Spine J 6 6 (1997) 385-389
-
(1997)
Eur Spine J
, vol.6
, Issue.6
, pp. 385-389
-
-
Roberts, S.1
McCall, I.W.2
Menage, J.3
Haddaway, M.J.4
Eisenstein, S.M.5
-
24
-
-
0009166694
-
Das gesetz der tranformation der knochen
-
Wolff J.D. Das gesetz der tranformation der knochen. Berlin Hirschwald (1892)
-
(1892)
Berlin Hirschwald
-
-
Wolff, J.D.1
-
25
-
-
0018880480
-
The bone mineral content and ultimate compressive strength of lumbar vertebrae
-
Hansson T., Roos B., and Nachemson A. The bone mineral content and ultimate compressive strength of lumbar vertebrae. Spine 5 1 (1980) 46-55
-
(1980)
Spine
, vol.5
, Issue.1
, pp. 46-55
-
-
Hansson, T.1
Roos, B.2
Nachemson, A.3
-
26
-
-
0022746124
-
Internal disc disruption. A challenge to disc prolapse fifty years on
-
Crock H.V. Internal disc disruption. A challenge to disc prolapse fifty years on. Spine 11 6 (1986) 650-653
-
(1986)
Spine
, vol.11
, Issue.6
, pp. 650-653
-
-
Crock, H.V.1
-
28
-
-
0027587606
-
Spinal compression tolerance limits for the design of manual material handling operations in the workplace
-
Genaidy A.M., Waly S.M., Khalil T.M., and Hidalgo J. Spinal compression tolerance limits for the design of manual material handling operations in the workplace. Ergonomics 36 4 (1993) 415-434
-
(1993)
Ergonomics
, vol.36
, Issue.4
, pp. 415-434
-
-
Genaidy, A.M.1
Waly, S.M.2
Khalil, T.M.3
Hidalgo, J.4
-
29
-
-
0003750325
-
Response of the lumbar spine due to shear loads
-
Paper presented at:, Wayne State University, Detroit MI
-
Cripton P, Berleman H, Visarius H, Begeman PC, Nolte LP, Prasad P. Response of the lumbar spine due to shear loads. Paper presented at: Symposium: Injury prevention through biomechanics, 1995; Wayne State University, Detroit MI.
-
(1995)
Symposium: Injury prevention through biomechanics
-
-
Cripton, P.1
Berleman, H.2
Visarius, H.3
Begeman, P.C.4
Nolte, L.P.5
Prasad, P.6
-
30
-
-
0001749759
-
The effect of forward leaning on lumbar intradiscal pressure
-
Nachemson A. The effect of forward leaning on lumbar intradiscal pressure. Acta Orthop Scand 35 (1965) 314-328
-
(1965)
Acta Orthop Scand
, vol.35
, pp. 314-328
-
-
Nachemson, A.1
-
31
-
-
0013827097
-
In vivo discometry in lumbar discs with irregular nucleograms. Some differences in stress distribution between normal and moderately degenerated discs
-
Nachemson A. In vivo discometry in lumbar discs with irregular nucleograms. Some differences in stress distribution between normal and moderately degenerated discs. Acta Orthop Scand 36 4 (1965) 418-434
-
(1965)
Acta Orthop Scand
, vol.36
, Issue.4
, pp. 418-434
-
-
Nachemson, A.1
-
32
-
-
75949155598
-
In vivo measurements of intradiscal pressure
-
Nachemson A.L., and Morris J. In vivo measurements of intradiscal pressure. J Bone Joint Surg 46A (1964) 1077-1092
-
(1964)
J Bone Joint Surg
, vol.46 A
, pp. 1077-1092
-
-
Nachemson, A.L.1
Morris, J.2
-
33
-
-
77949780333
-
Chapter 16 - NeuDisc
-
Kim D.H., Cammisa F.P., and Fessler R.G. (Eds), Thieme Medical Publishers inc., New York
-
Bertagnoli R., Prewett A., Yue J.J., and Sabatino C. Chapter 16 - NeuDisc. In: Kim D.H., Cammisa F.P., and Fessler R.G. (Eds). Dynamic Reconstruction of the Spine (2006), Thieme Medical Publishers inc., New York 122-127
-
(2006)
Dynamic Reconstruction of the Spine
, pp. 122-127
-
-
Bertagnoli, R.1
Prewett, A.2
Yue, J.J.3
Sabatino, C.4
-
34
-
-
0036023527
-
A literature review of the association between wear rate and osteolysis in total hip arthroplasty
-
Dumbleton J.H., Manley M.T., and Edidin A.A. A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplasty 17 5 (2002) 649-661
-
(2002)
J Arthroplasty
, vol.17
, Issue.5
, pp. 649-661
-
-
Dumbleton, J.H.1
Manley, M.T.2
Edidin, A.A.3
-
35
-
-
84858857093
-
An investigational study of nucleus pulposus replacement using an in-situ curable polyurethane. An in vivo non-human primate model
-
Paper presented at:, May 1-4, Berlin, Germany
-
Cunningham B, Hu N, Beatson HJ, McAfee P, Yuan HA. An investigational study of nucleus pulposus replacement using an in-situ curable polyurethane. An in vivo non-human primate model. Paper presented at: Spine Arthroplasty Society; May 1-4, 2007; Berlin, Germany.
-
(2007)
Spine Arthroplasty Society
-
-
Cunningham, B.1
Hu, N.2
Beatson, H.J.3
McAfee, P.4
Yuan, H.A.5
-
36
-
-
0036381564
-
Standardized analysis of UHMWPE wear particles from failed total joint arthroplasties
-
Mabrey J.D., Afsar-Keshmiri A., Engh G.A., et al. Standardized analysis of UHMWPE wear particles from failed total joint arthroplasties. J Biomed Mater Res 63 5 (2002) 475-483
-
(2002)
J Biomed Mater Res
, vol.63
, Issue.5
, pp. 475-483
-
-
Mabrey, J.D.1
Afsar-Keshmiri, A.2
Engh, G.A.3
-
37
-
-
83255180056
-
A Rabbit Model to Evaluate the Biological Response to DASCOR™ Device Wear Debris
-
Paper presented at:, May 1-4, Berlin, Germany
-
Lacy S, Johnson C, Long PH, et al. A Rabbit Model to Evaluate the Biological Response to DASCOR™ Device Wear Debris. Paper presented at: Spine Arthroplasty Society; May 1-4, 2007; Berlin, Germany.
-
(2007)
Spine Arthroplasty Society
-
-
Lacy, S.1
Johnson, C.2
Long, P.H.3
|